Protocol: P (PROFINET®), Mounting: 8 (DIN Rail Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: 9 (EtherNet/IP™), Mounting: 7 (Screw Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: 9 (EtherNet/IP™), Mounting: 8 (DIN Rail Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: L (IO-Link), Mounting: 8 (DIN Rail Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: M (CC-Link), Mounting: 7 (Screw Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: P (PROFINET®), Mounting: 7 (Screw Mounting), Cable Connector: w/o Plug Connector, Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Protocol: P (PROFINET), Number of Axes, Special Specification: F (1 Axis, w/STO Sub-function), Mounting: 7 (Screw Mounting), Actuator: LER, Table Accuracy: Basic Type, Body Size: 30, Max.Rotating Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: 1 (Continuous Rotation: 360°)
Table Accuracy: Basic Type, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.22; LER30: 0.8; LER50: 6.6), Motor Cable Entry: Basic Type, Entry on Right Side, Actuator Cable Type: R (Robotic Cable, Flexible Cable), Actuator Cable Length: B (15m), Controller Type - JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), Controller Mounting: 8 (DIN Rail Mounting)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R5 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge; 0.4 MPa )
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R5 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge; 0.4 MPa )
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: B (Bracket), Control Unit: R5 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge; 0.4 MPa )
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: N (None), Bracket Option: B (Bracket), Control Unit: R5 (w/Control Unit, Supply Port: Right Side, With regulator, Round type pressure gauge; 0.4 MPa )
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: A (NPN, 2 Outputs), Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: R5 (w/Control
Length: R5 (5m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail), I/O Cable: 1 (I/O Cable, 1.5m)
, Actuator Cable Type, Length: R5 (5m), Controller: CM1 (CC-Link Ver. 1. 10), Mounting: 8 (DIN Rail), I/O Cable: w/o Cable, Communication Plug Connector: T (T-branch Type Communication Plug Connector)