The station No. of CC-Link is shown. (01 to 64) The communication speed of CC-Link is shown. STATION NO Switch name Set range Description STATION NO.(X10) Set upper bits of the station. 01 to 64 STATION NO.(X1) Set lower bits of the station. The CC-Link address setting at the time of the factory shipment is set in 01".
-1A, 1NA SX5000-64-1A 1NA -1A:+COM -1NA:-COM 5-2 Connector block assembly (for 26 pins flat cable) SX3000-64-2A-26 2NA SX5000-64-2A-26 2NA Note) For 24 VDC -2A:+COM -2NA:-COM 5-3 Connector block assembly (for 20 pins flat cable) SX3000-64-2A-20 2NA SX5000-64-2A-20 2NA 5-4 Connector block assembly (for 10 pins flat cable) SX3000-64-2A-10 2NA SX5000-64-2A-10 2NA Connector block assembly (for2to8stations
64 20 55 78.5 10 58 17 58 M16 x 1.5 87.5 117 7 41 33 118.5 232.5 63 74 74 20 69 82 12 72 17 58 M16 x 1.5 91 120.5 5.5 48 39 122 236 Note) Refer to pages 13 and 14 for accessories.
+0.070 0 +0.5 +0.3 +0.070 0 44 24 24 31 M26 x 1.5 M26 x 1.5 64 72 +0.084 0 +0.5 +0.3 +0.084 0 Knuckle pin and snap rings are included.
Rear flange With auto switch W/o auto switch Bore (mm) Stroke range (mm) FD FT FV FX FZ L L1 B 17 17 19.5 22.5 A 31 31 42 45.5 B 22 22 29.5 32.5 A 26 26 32 35.5 12 16 20 25 4.5 4.5 6.6 6.6 5.5 5.5 8 8 25 30 39 42 45 45 48 52 55 55 60 64 3.5 3.5 4.5 5 14 15.5 18.5 22.5 5, 10 (All dimensions are common between standard stroke and long stroke except "A", "B" and "CL".)
) 49 (64) Manual override PA 2-8 mounting hole Indicator light P R2 R1 2-8 mounting hole Indicator light 49 (64) 49 (64) M12 connector M12 connector 126.5 (139.5) 126.5 (139.5) PE port PE port PE port PE port 50 (63) 3 5 38 (53) 50 (63) 32 (42) 3 5 1 38 (53) 23 (30) 32 (42) 1 23 (30) 1/8 14 port 3/8, 1/2, 3/4-2 port 3, 5 port 30 (42) 30 (42) 1/8 14 port 3/8, 1/2, 3/4-2 port 3, 5 port 30 (
D H11 FB TG 0.2 E R MF TF UF L4 Screw size L4 32 F5032 30 7 32.5 50 32 10 64 79 5 M6 x 20L 40 F5040 35 9 38 55 36 10 72 90 5 M6 x 20L 50 F5050 40 9 46.5 70 45 12 90 110 6.5 M8 x 20L 63 F5063 45 9 56.5 80 50 12 100 120 6.5 M8 x 20L 80 F5080 45 12 72 100 63 16 126 153 9 M10 x 25L 100 F5100 55 14 89 120 75 16 150 178 9 M10 x 25L D TG R E FB * Supplied with 4 mounting screws.
17 15 65 398 *1 Minimum stroke for trunnion mounting: 1 mm for bore size 32 to 80, 5 mm for bore size 100, 10 mm for bore size 125 Bore size [mm] d e f l h 1 to 50 901 to 1000 32 54 36 23 12.5 25 37.5 50 75 100 125 150 175 200 225 250 75 88 100 113 138 163 188 213 238 263 288 313 40 54 36 23 12.5 25 37.5 50 75 100 125 150 175 200 225 250 75 88 100 113 138 163 188 213 238 263 288 313 50 64
(a) Station numbers may be set within the range 1 to 64. (b) One driver occupies 1 or 2 stations.
Settings1 Content Operating Number of Word area mode 1 2 3 CC-Link Bit area Extended cyclic occupied input/output size input/output2 version (Ver2.00) stations (RWr/RWr) 1 OFF OFF OFF 1.10 1 32/32 4 word/4 word 2 ON OFF OFF 1.10 2 64/64 8 word/8 word 3 OFF ON OFF 1.10 3 96/96 12 word/12 word 4 ON ON OFF 1.10 4 128/128 16 word/16 word 5 OFF OFF ON 2.00 1 64/64 16 word/16 word 4 times 6 ON
Extended cyclic occupied units RX/RY stations 1 15 1.10 x1 2 64/64 8/8 2 15 1.10 x1 4 128/128 16/16 3 15 2.00 x8 2 384/384 64/64 4 15 2.00 x8 4 896/896 128/128 5 31 2.00 x8 2 384/384 64/64 6 31 2.00 x8 4 896/896 128/128 7 63 2.00 x8 4 896/896 128/128 8 127 2.00 x8 4 896/896 128/128 * The last register of the bit area (16 bits) cannot be used as it is allocated for the system area.
Maximum load mass (Wmax) + Static moment (M) n = Load mass (W) Allowable static moment (Mmax) + Dynamic moment (Me) Allowable dynamic moment (Memax) 1 Moment Load Mass Maximum Load Mass (Static moment/Dynamic moment) Allowable Moment W (kg) (Nm) Wmax Model M2 M1 1.5 M3 1.5 M2 26 85 96 M3 28 56 64 M1 28 56 64 Model REAH10 REAH15 REAH20 Model REAH25 REAHT25 REAHT32 REAH10 4 2.5 REAH15 9 16
64 20 55 78.5 10 58 17 58 M16 x 1.5 87.5 117 7 41 33 118.5 232.5 63 74 74 20 69 82 12 72 17 58 M16 x 1.5 91 120.5 5.5 48 39 122 236 Note) Refer to pages 13 and 14 for accessories.
+0.070 0 +0.5 +0.3 +0.070 0 44 24 24 31 M26 x 1.5 M26 x 1.5 64 72 +0.084 0 +0.5 +0.3 +0.084 0 Knuckle pin and snap rings are included.
Contents 125 CLS125-PS A set of above Nos. 60, 62, 63, 64, 65 & 67. 140 CLS140-PS 160 CLS160-PS Since the lock section for Series CLS is normally replaced as a unit, replacement seal kits are for the cylinder section only.
ZZ + Stroke H 3.5 (mm) ZZ S P I E D A H H1 13.5 10.5 10.5 10.5 FL Bore size H2 41 32 32 26 B2 22 17 17 13 B1 AL K 11 8 8 8 13 F 12 10 8 6 KA MM NA NN G 0 50 45 45 41 6 6 5 8 8 8 40 32 25 20 24 22 22 18 21 19.5 19.5 15.5 14 12 10 8 20-0.033 M14 x 1.5 M10 x 1.25 M10 x 1.25 M8 x 1.25 M26 x 1.5 M26 x 1.5 M20 x 1.5 46.5 37.5 33.5 28 7 5.5 5.5 5 42.5 34.5 30 24 154 122 120 116 1/8 88 64 62 62 16
When mounting and removing the product, use the specified places shown in page 64 to apply tools. Also, when mounting, tighten to the specified torque shown in page 64. Excessive torque or applying a tool to places other than the specified place can cause damage or loss of original performance. 6.
64 Air Cylinder: Direct Mount Type Single Acting, Single Rod, Spring Return/Extend Series CJ2R 10, 16 How to Order Standard stroke (mm) 10 16 15, 30, 45, 60 15, 30, 45, 60, 75, 100, 125, 150 Bore size Intermediate strokes are available by the 1 mm interval with no stroke adjustment by spacer.
Alarm for Motor Control 64 15.1 Alarm group signals 64 15.2 Reading PROFINET Diagnostics from the JXCPH 65 15.3 Alarms and countermeasures 66 16. Precautions for wiring and cable 71 17.
The station No. of CC-Link is shown. (01 to 64) Set the CC-Link communication speed. STATION NO. Switch name Set range Description STATION NO. (X10) Set upper bits of the station. 01 to 64 STATION NO. (X1) Set lower bits of the station. The CC-Link address setting at the time of the factory shipment is set in 01".