SMC Corporation of America
Elite Part Number Search
Search Results "LEFS40EH-750-R5"

DMA-625 5 18-18 DMA-750 34-16 DMA-875 78-14 DMA-1000 1-14 DMA-1250 114-12 www.poweraire.com 1-800-526-7661 18 Section II: Cylinders High Temperature Operations Q: I have an application in a high temperature environment. What should I do to avoid complication? A: The control valve powering the cylinder should be mounted as far away from the heat as possible.

.: Uni-wire H System DeviceNet CC-Link Applicable system Protocol Communication specification Output specification Environmental resistance Release 2.0 Ver. 1.10 Version Note 1) 156 k/625 kbps 2.5 M/5 M/10 Mbps 750 kbps 28.5 kbps Communication speed 125 k/250 k/500 kbps 28.5 kbps 29.4 kbps Specified file Note 2) EDS file 32/32 (1 station, remote I/O stations) Occupied area (Number of inputs

Body size Body size 20 L/min 100 L/min Symbol Filtration area 750 mm2 Specifications Different diameters (IN side < OUT side) Different diameters (IN side > OUT side) Blue element Filtration: 10 m FKM/Oil free (Seal) Nylon Symbol X01 X02 X03 X04 X05 X06 5 7 1260 mm2 Applicable tubing O.D.

Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders

T dimension) None Differential pressure indicator Differential pressure indication switch Note) 0 1 5 1 2 3 4 5 1 2 3 4 1 2 3 4 340 410 480 550 620 430 530 630 730 560 650 750 850 04 (1/2B) 06 (3/4B) 08 (1B) 30 FH FH Note) N.C. and N.O. common Note) When the differential pressure indication 1 or 5 is selected, the connection method is 2 to 5. (0 and 1 cannot be selected.)

Symbol Specications X01 Different diameters (IN side < OUT side) X02 Different diameters (IN side > OUT side) X03 Blue element X04 Filtration: 10 m X05 FKM/Oil free (Seal) X06 Nylon 5 20 L/min 750 mm2 7 100 L/min 1260 mm2 Applicable tubing O.D. Metric size Symbol Applicable tubing O.D.

2 600st 400st 500st st: Stroke (mm) MGF 1 100st 200st 300st 0 MGZ 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGT MGGM 100Stroke 8 (Slide bearing type) 7 6 Deflection Y (mm) 1300st 5 1200st 4 1100st 1000st 3 900st D800st 2 600st 700st -X st: Stroke (mm) 400st 500st 1 100st 200st 300st Individual -X 0 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750

The speed is as indicated below for motorless operation of test operation. 0 0 r/min 1 to 50 Driver capacity [W] Servo motor speed [r/min] 100V class 100 to 400 3000 200V class 100 to 750 1k to 37k 2000 400V class 600 to 55k Analog speed limit maximum speed 0 0 5 35 5. PARAMETERS Used to set the speed at the maximum input voltage (10V) of the analog speed limit (VLA).

.-99.9 kPa) Combination conditions with other parameters : P1+H2 P1 999 (750) ... ... ... ... ... 16 2 R/W 0x02EE Energy saving operation threshold (P2) of CH15 (750) 3.4.4. Hysteresis H2 (Index 67) Table 3-12.

Allowable theoretical strokes (mm) Mounting type Accessories Pressure Bore (mm) [MPa] 32 40 50 63 80 100b L F (front) G (rear) 0.2 680 980 1220 1410 0.3 540 1020 790 980 1140 L 0.4 460 700 880 680 840 980 0.5 410 630 780 610 750 880 F (front) 0.6 370 580 710 550 680 800 0.7 340 520 650 500 620 730 0.8 310 480 600 460 580 680 0.9 290 450 570 430 540 630 1 270 420 530 400 510 590 0.2 580

Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa (145psi) Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa (7psi) Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.

Note 2) When compressor discharge concentration is 30mg/Nm Specifications Models Model AMG150 AMG250 Drain Catch Series AMG Compressed air 1.0MPa Fluid Maximum operating pressure Rated flow rate Note) l/min (ANR) 300 750 Note) 0.05MPa Min. operating pressure Proof pressure The AMG series is installed in air pressure lines to remove water droplets from compressed air.

operating pressure 10 to 60C Ambient and fluid temperature 50 to 600mm/s Piston speed Non-lube Lubrication 0 to 250st: +1.0, 251 to 1000st: +1.4, 1001st and up: +1.8 Stroke length tolerance 0 0 0 Direct mount type Mounting Standard Strokes Maximum stroke with switch (mm) Bore size (mm) Standard stroke (mm) Maximum manufacturable stroke (mm) 150, 200, 250, 300, 350, 400 450, 500 15 1000 750

900st 1.5 800st 700st 1 600st st: Stroke (mm) 400st 500st 0.5 100st 200st 300st 0 0 50 100 150 200 250 300 350 400 450 500 550 600 Allowable end load F (N) MGGM 100Stroke 4 (Slide bearing type) 3.5 3 Deflection Y (mm) 1300st 2.5 1200st 1100st 2 1000st 1.5 900st 800st 1 600st 700st st: Stroke (mm) 500st 0.5 400st 100st 200st 300st 0 0 100 50 150 200 250 300 350 400 450 500 550 600 650 700 750

150 300 SQ2000 0.82 0.65 450 600 750 Cylinder speeds marked with a are controlled by a fixed orifice.

Positioning distance (mm) 1 10 100 750 1500 10 1.1 2.0 11.0 76.0 151.0 100 1.1 1.2 2.1 8.6 16.1 Speed (mm/s) 500 1.1 1.2 1.4 2.7 4.2 1000 1.1 1.2 1.4 2.1 2.9 Values will vary slightly depending on the operating conditions.

Static Neutralization Characteristics e Potential Amplitude IZS40, 41 Supply pressure: 0.3 MPa With high speed de-ionizing cartridge With energy saving type de-ionizing cartridge 2000 2000 1750 1750 Potential amplitude (V) Potential amplitude (V) 1500 1500 1250 1250 1000 1000 1 Hz 1 Hz 30 Hz 750 750 30 Hz 500 500 250 250 0 0 0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance

10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) 50 to 6000 psig (0.34 to 41.4 MPa) 100 to 10 psig (0.7 to 69 MPa) Operating Parameters Delivery pressure Gas Source pressure Select compatible materials of construction for the gas SS body (Material code C or S): 69 MPa (10 psig) 2), Brass body (Material code B): 41.4 MPa (6000 psig) 750

inlet Ventilation air outlet 715 40 or less 954 330 10 1538 A 1026 984 627 677 Anchor bolt mounting position (View A) For piping port sizes, refer to the Parts Description on page 330. 328 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Dimensions HRL300-Am-20 Ventilation air inlet Ventilation air inlet Ventilation air outlet 850 40 or less 1079 330 10 1839 A 1145 1109 700 750

Action Single acting, Single rod Fluid Air Proof pressure 1.5 MPa Max. operating pressure 1.0 MPa Min. operating pressure Rubber bumper Spring return: 0.18 MPa Spring extend: 0.23 MPa Ambient and fluid temperature Without auto switch: 20C to 80C (No freezing) With auto switch: 10C to 60C (No freezing) Lubricant Not required (Non-lube) Stroke length tolerance +1.4 0 mm Piston speed 50 to 750