150 175 AMV3-10 AMV6-14 AMV15-20 AMV37-20 AMV75-30 AMV160-40 R1 R1 1/2 R2 R2 80 (3B) JIS 10K FF flange 100 (4B) JIS 10K FF flange 789
CX CZ L RR 25 15 to 100 14 20 18 36 14.5 10 105 to 200 32 20 to 100 14 22 18 36 18.5 10 105 to 200 63 50 to 200 22 30 22 44 37.4 14 205 to 500 505 to 800 Material: Cast iron (Coating) * The A and CL measurements are when the unit is in the Z-phase first detecting position.
Caution 5 150 100 200 300 1.
W Double rod K* Non-rotating * available for 150, 200 and 250 bores only ** use single rod designation when ordering XC11 kit Note: XC10 seal kit order 2 single rod kits *** not available with K option How To Order Tie Rods NC1A 150 11 2759 0400 How To Order Cylinder Tube Double Acting Single Rod Applicable Bore Tie Rod Size Bore 150 150 2759 200 200 2760 250 200 2760 325 325 2761 400 325
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
C J G5-S Standard Stroke CV Bore size (mm) Standard stroke (mm) Symbol Specifications 40 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500 -XA Change of rod end shape MVGQ 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper 80, 100 25, 50, 75, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700 Piston rod and rod end nut
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
V 200 V or less 3-wire (NPN equiv.)
CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin arrangement CS1 3 4 4 3 3 C76 JIS C 4524, JIS C 4525, IEC 947-5-2, NECA 0402 300 m/s2 Applicable standards Impact resistant IP degress of protection Insulation resistance Withstand
CM2 Bore size (in) Model no. 150 (1.5") 200 (2") 250 (2.5") 325 (3/25") 400 (4") D-A5, D-F5 D-A6, D-J5 NBT-150 NBT-200 NBT-200 NBT-325 NBT-325 CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MB MB1 Connector type M8-3 pin M8-4 pin M12-4 pin 1 2 1 4 CA2 2 1 Pin
200 100 0 B 800 700 600 500 400 300 200 100 0 C 800 700 600 500 400 300 200 100 0 D 800 700 600 500 400 300 200 100 0 E It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.
Chart (1) 400 st 500 st 600 st 700 st 400 st 500 st 600 st 700 st 10 5 4 300 st 300 st 3 200 st 200 st Load movement time: t (S) 2.
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
VAC For single phase 200 VAC L1 CNP1 NFB MC CNP3 L1 CNP1 NFB MC CNP3 Single phase 200 to 230 VAC Three phase 200 to 230 VAC L2 L2 U U U Motor V U Motor V L3 L3 V V W M N () W M N W W P1 P1 PE PE P2 P2 CNP2 CNP2 P (+) P Regeneration option Regeneration option C C D D Detector Detector CN2 CN2 L11 L11 L21 L21 Note) For single phase 200 to 230 VAC, power supply should be connected to L1 and
MHZ MHC2/MHCA2/MHCM2 MHF MHL F MHR L MHK MHS F MHC MHC2-6D/MHCA2-6D MHC2-6S/MHCA2-6S MHCM2-7S MHT Pressure 0.6MPa 4 4 2 MHY Pressure 0.6MPa 0.5 Pressure 0.6MPa MHW Gripping force N Gripping force N Gripping force N 3 3 0.4 MRHQ 0.5 0.5 Misc. 2 2 1 0.3 0.4 0.4 D0.2 1 1 0.3 200 30 20 10 0 30 20 10 0 30 20 10 Gripping point L mm Gripping point L mm Gripping point L mm 12-8-11 12 Series MHC2/
A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)
Example: Allowable load F (N) = M (Maximum allowable moment) (Nm) L x 10-3 0.68 30 x 10-3 Allowable load F = Unit conversion factor = 22.7 (N) > 10 Since load F > f, it is operable. 12-11-11 12 Series MRHQ Moment of Inertia and Allowable Kinetic Energy Moment of Inertia Calculation and Allowable Kinetic Energy Graph (Moment of inertia and rotation time) 200 Calculate the moment of inertia
Light gray (GR2) Neon pink (P1) Solid purple (PU1) Clear purple (PU2) Caution Solid red (R1) Clear red (R2) 1. Applicable for general industrial water. Please consult with SMC if using for the other kind of fluid. Also, the surge voltage pressure must be under the maximum operating pressure.
-X C76F32B C76F40B Standard stroke (mm) 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 Bore size (mm) 32 40 Max. stroke (mm) Mounting bracket 1000 Trunnion Clevis Single knuckle joint Double knuckle joint Floating joint C76T32 C76C32 KJ10DA GKM10-20A JA25-10-150 C76T40 C76C40 KJ12DA GKM12-24A JA40-12-175 20Example of How to Order Data Accessory 1.
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.