Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke (mm) 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and interpolation) 15 8 4 18
Actuator Specifications Supplement 1.1 Initial setting of LEY/LEYG series Model LEY16/LEYG16 LEY25/LEYG25 LEY32/LEYG32 LEY40/LEYG40 Lead symbol A B C A B C A B C A B C Lead [mm] 10 5 2.5 12 6 3 16 8 4 16 8 4 Stroke [mm] 300 300 300 400 400 400 500 500 500 500 500 500 Max. speed [mm/s] 500 250 125 500 250 125 500 250 125 300 150 75 Min. speed [mm/s] (Independent and 15 8 4 18 9 5 24 12 6 24
Linearity (77F) 0.15% F .S. Repeatability (77F) 0.6% F .S. 0.5% F .S.
Collision speed (mm/s) L unit L unit 1000 1000 Air cushion Air cushion 500 400 300 500 400 300 200 200 100 1 2 3 4 5 10 20 30 100 2 3 4 5 10 20 30 0.5 40 50 100 Load mass (kg) Load mass (kg) 40 Horizontal collision: P = 0.5 MPa 20 Horizontal collision: P = 0.5 MPa 2000 1500 2000 1500 Collision speed (mm/s) Collision speed (mm/s) L unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit
S S Effective area ratio 3.2 : 1 Pressure loss: Small Filter regulator S coupler Coil tube 2 Nozzle 2 Upstream side S: 9 Nozzle side S: 2.8 Effective area (mm) Effective area ratio Nozzle size (mm) Number of nozzles Supply pressure S: S = 3.2 : 1 2 1 0.5MPa 0.35MPa 0.33MPa Regulator pressure Outlet pressure Effect of Energy Saving Improvement 50 to 75% Reduction 50 to 75% Reduction 100%
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
The kinetic energy of load can be found using the following formula. 20 10 5 V M M 2 V 2 100 300 1000 2000 500 Ek = Ek: Kinetic energy (J) M: Weight of load (kg) V: Piston speed (m/s) Maximum drive speed (mm/s) Example) Load limit at rod end when air cylinder 63 is actuated with max. actuating speed 500 mm/s. at a maximum drive speed of 500 mm/s.
0.2% F .S. 1 digit Temperature characteristics 2% F .S. (25C standard) Output type Select from NPN or PNP open collector output.
(mm) TA TB TC S 94 94 96 103 ZZ 131 136 138 155 S 119 119 121 128 ZZ 156 161 163 180 S 144 144 146 153 ZZ 181 186 188 205 ZZ 211 213 230 20 25 32 40 11 11 11 12 11 11 10 10 M5 x 0.8 M6 x 0.75 M8 x 1.0 M10 x 1.25 169 171 178 Note) The drawing below shows the single acting/spring return style.
Load rate: 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation SYJ5140-01 Cylinder is in extending.
kPa 1 MPa 100 kPa 0 100 kPa 500 kPa 1 MPa 101 kPa 101 kPa For vacuum pressure Withstand pressure 500 kPa Withstand pressure 500 kPa 0 0 Rated pressure range 100 kPa 100 kPa For compound pressure Withstand pressure 500 kPa Withstand pressure 500 kPa 100 kPa 100 kPa 100 kPa 100 kPa For positive pressure 1 MPa 1 MPa 1 MPa Withstand pressure 1.5 MPa Withstand pressure 1.5 MPa 2 MPa 2 outputs
Standard Strokes [mm] Bore size [mm] Standard stroke [mm] 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50, 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 80, 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700 Note) Intermediate strokes not listed above are produced upon receipt of order.
Revision history Addition of 24 VAC to Rated voltage for Series VP300/500/700. Addition of -X505 to Made to Order for Series VP300/500. Addition of -X505 to Made to Order for Series VPA300/500. OZ Edition B Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance (mm) Installation distance (mm) Supply pressure: 0.3 MPa (17.6 L/min [ANR] per cartridge) Supply pressure: 0.3 MPa (8.6 L/min [ANR] per cartridge) 12 12 10 10 Discharge time (s) Discharge time (s) 8 8 6 6 30 Hz 1 Hz 30 Hz 1 Hz 4 4 2 2 0 0 0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance (mm) Installation
mm/s or more 50 mm/s or more REC r r Piston speed Piston speed Control stroke Smooth Smooth Less than 500 mm/s Thrust control length less than 2 mm Less than 50 mm/s Less than the minimum operating pressure Without balancer or thrust control 100 mm/s or more Low Speed Low Speed qwe t t Follow-up speed Low pressure, low thrust Low sliding MQ The minimum operating pressure or more Less than
0.1MPa 0.2MPa 8 8 0.3MPa 0.2MPa Discharge time [s] Discharge time [s] 1 s s 0.4MPa 0.3MPa 0.4MPa 0.5MPa 6 6 0 0 0.5MPa 50 500 50 500 4 4 2 2 0 0 0 500 1000 1500 2000 0 300 600 900 1200 1500 mm mm Installation distance [mm] Installation distance [mm] 1) Without air purge For IZS41-1120/J/V-F 2) With High speed static neutralization cartridge With air purge, For IZS41-1120-F 2 6 0.3 5 1.5
Cylinder stroke (mm) Suffix for stroke adjusting unit Nil S 50, 100, 150, 200 250, 300, 350, 400 450, 500, 550, 600 16, 20 25, 32, 40 Both ends One end Note) S is applicable for stroke adjusting units L and H.
501 to 600 601 to 700 701 to 800 801 to 900 901 to 1000 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 301 to 400 401 to 500 501 to 600 601 to 700 701 to 800 801 to 900 133 ISO Standard (15552) Air Cylinder: Standard Type Double Acting, Single/Double Rod CP96 Series Dimensions Basic: CP96S (D) B C (J) W Bore size Stroke 32, 40 C85 C85W C85-S/T C75-S/T C85K-S/T C75K-S/T C85K C75K C75R
, Hyteresis Repeatability With 50% of signal input 1 0.8 1 Output deviation factor (% F .S.)