VQZ3000 VFS VS 0.7 0.9 VS7 Bore size (mm) Cylinder speed (mm/s) Base mounted (With sub-plate) Cv Series CJ2 Series CM2 Series CA1 6 10 16 20 25 32 40 40 50 63 80 100 150 300 VQZ1000 Body width 10 450 0.3 V V V 600 750 150 300 VQZ2000 Body width 15 0.6 450 V 600 V V 750 150 300 VQZ3000 Body width 18 0.9 450 V V V V V 600 750 Cylinder speed marked with can be controlled by speed controller
Petroleum, Water-glycol, Emulsion: NBR; Phosphoric ester: FKM, EPDM Model Flange port size Note) Rated flow rate (L/min) Model/Rated Flow Rate FHIA-04 FHIA-06 FHIA-08 FHIA-10 FHIA-12 FHIA-16 FHIA-20 FHIA-24 FHIA-28 FHIA-32 1/2B 30 3/4B 50 1B 95 1 1/4B 150 1 1/2B 220 2B 350 2 1/2B 550 3B 770 3 1/2B 1000 4B 1300 The symbol represented by indicates the type of applicable hydraulic fluid.
Volume GR-L-005 5 g GR-L-010 10 g GR-L-150 150 g 3. Do not wipe off grease from the sliding part of the air cylinder.
) 53 (63) 150 (150) 63 (63) Note 1) ( ): Denotes the dimensions with auto switch.
ZK2 Combination Manifold n: Stations L: Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 101 110 119 128 137 146 155 164 173 182 191 200 209 218 227 L2 61.4 70.4 79.4 88.4 97.4 106.4 115.4 124.4 133.4 142.4 151.4 160.4 169.4 178.4 187.4 L3 135.5 148 160.5 160.5 173 185.5 185.5 198 210.5 223 223 235.5 248 248 260.5 L4 125 137.5 150 150 162.5 175 175 187.5 200 212.5 212.5 225 237.5 237.5
Conditions Body ported Tube bore x Length Speed controller Silencer Series CJ2 Series CM2 6 x 1 m AS3301F-06 12 x 1 m AS4001F-12 AN200-02 Series MB 6 x 1 m AS2301F-06 AN110-01 VZ5120-01 3-3-55 Series VZ5000 Construction 2 position single 2 position double De-energized De-energized 3 position closed center/exhaust center/pressure center 3 position closed center De-energized De-energized 3
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Caution When making connections, take note that using other than the supported size (3.5 to 7) heavy-duty cord will not satisfy IP65 (enclosure) standards. Also, be sure to tighten the ground nut and holding screw within their specified torque ranges.
Igm: Leakage current of the servo motor (Found from Table 11.4.) 120 120 100 100 Leakage current Leakage current 80 80 60 60 40 40 [mA] [mA] 20 20 0 2 0 14 100 5.5 38 2 3.5 8 1422 38 80 150 5.5 30 60 100 3.5 8 22 60 150 30 80 Cable size[mm2] Cable size[mm2] a. 200V class b. 400V class Fig. 11.3 Leakage current example (lg1, lg2) for CV cable run in metal conduit 11 30 11.
SY100-61-3-05 SY100-61-3-06 SY100-61-2-01 SY100-61-2-02 SY100-61-2-03 SY100-61-2-04 Voltage symbol 24V 12V 100V 200V 110V 220V Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC How to use DIN Terminal Caution Connection 1. Loosen the holding screw and pull the connector out of the solenoid valve terminal block. 2.
Analog monitor output voltage 1 [V] Gain adjustment 1000 [min-1] Motor speed Item Specifications Gain-adjustment Range 10050% Adjustment Unit 0.4%/LSB The gain adjustment range is made with a 100% output set as a center value (adjustment range: 50% to 150%). The following is a setting example.
YV Sizes 40-06, 50, and 60 have been added to the AC series. Sizes 40-06, 50, and 60 have been added to the AF, AR(K), and AL. The VHS40-06 and 50 have been added. Size 40-06 has been added to the AFM/AFD. Sizes 40-06 and 60 have been added to the AW(K). Made to order options have been added. Number of pages has been increased from 104 to 112.
WETTED MATERIALS Polysulfone, Silicone, Buna-N TEMPERATURE RANGE 40 150 F (4 66 C) REPEATABILITY < +/1% F.S.
Mist Separator, Exhaust Cleaner For VBA40A-04 For VBA42A-04 For VBA43A-04 Model For VBA10A-02 For VBA11A-02 For VBA20A-03 For VBA22A-03 Description Mist separator Exhaust cleaner AM250C-02 AMC310-03 AM450C-04, 06 AMC510-06 AM550C-06, 10 AMC610-10 Note) Refer to page 1022 for air tanks, page 223 for mist separators and Best Pneumatics No.7 for exhaust cleaners.
Standard Stroke Bore size (mm) Standard stroke (mm) 25, 50, 75, 100, 125, 150, 175, 200, 250, 32 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 40 300, 350, 400, 450, 500 25, 50, 75, 100, 125, 150, 175, 200, 250, 50 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 63 300, 350, 400, 450, 500, 600 25, 50, 75, 100, 125, 150, 175, 200, 250, 80 300, 350
0 to 150 Outstanding mechanical strength, heat resistance and chemical resistance.
oN Opd.tion: 360 it60 131) 130 360 360 130 150 150 r5n 150 1 1 0 150 150 i $'q (46.C) (4.5) 0,177 t'r.5) (10) 0.39,1 ool (5) (5) .) 0346 19.81 0.543 03.31 03.q M6di4 air {lub.i*td d 0ll.16}, .nd non.flflm.blo mn.torlci non{orcs!.
0 to 150 Outstanding mechanical strength, heat resistance and chemical resistance.
Supplv Pressure 220 PSIG (15 Kqflcmz) Operating Pressure 22-150 PS|G (1.5-9.9 Kqf/cm2) 15-150 PS|G (1-9.9 Kqf/cm2) Ooeratino TemDerature 40-140'F (5-60'C) Bodv Aluminum Die Cast Spool & Sleeve 440F Stainless Steel, passivated & heat treated to 58-63 Rockwell C. Sleeve O-Rinqs Buna N Soacer Delrin Shock Pad Urethane Rubber Max. Cycle Rate 300 cPM Weight (Valve Body Only) oz.
Supplv Pressure 220 PSIG (15 Kqflcmz) Operating Pressure 22-150 PS|G (1.5-9.9 Kqf/cm2) 15-150 PS|G (1-9.9 Kqf/cm2) Ooeratino TemDerature 40-140'F (5-60'C) Bodv Aluminum Die Cast Spool & Sleeve 440F Stainless Steel, passivated & heat treated to 58-63 Rockwell C. Sleeve O-Rinqs Buna N Soacer Delrin Shock Pad Urethane Rubber Max. Cycle Rate 300 cPM Weight (Valve Body Only) oz.
1 KBP2 1 KBP2 KB P 1 KBE2-06 Body size KBE2-06 KBV2-06 Model Plug: KBP Cap: KBC Component module KBV2-06 2 KBE2-06 2 KBN2 1 Model Model Bracket mounting thread M6 x 1 x 8 l KBC1 KBC2 KBC3 KBC4 KBP1 KBP2 KBP3 KBP4 KBN2 KBV1-06 Bracket mounting thread M6 x 1 x 8 l KBE2-06 KBV2-06 5 Bracket: KBX (P . 15-3-117) Component module KBP1 KBV2-06 1 KBV1-06 1 KBR2-1 1 KBH2-R2S 1 KBP1 1 KB