SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-N01-L"

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter), Option 3: K (Operation Manual, Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A2 (Bracket B, Horizontal Mounting), Option 3: T (w/o Operation Manual, Calibration Certificate)

This is a legacy product, and replaced byZSE20-N-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .34645 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature

This is a legacy product, and replaced byZSE20F-N-N01-L, SWITCH, VACUUM SERIES, ZSE30 VACUUM SWITCH, JD, ZSE30 1/8 PORTED, .17857 lb, ModelRated pressure rangeSet pressure rangeWithstand pressureMinimum unit settingApplicable fluidPower supply voltageCurrent consumptionSwitch output--RepeatabilityHystere- sisAnalog outputDisplayDisplay accuracyIndicator lightEnviron- ment resistanceTemperature

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8)

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -

Place them in alphanumerical order. q e w Switch Characteristics Description Symbol Example) IS10-N01-6PZ Nil N Rc NPT q q Thread type Max. contact capacity AC 2 A, DC 2 W 24 V or less Note 1) Set pressure range of 6P(L, Z) is 0.2 to 0.6 MPa (30 to 90 psi). This product is for overseas use only according to the new Measurement Law.

The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., PRESSURE SWITCH, INSTRUMENTATION, ISE20, CB, ISE20 1/8 INCH NPT VERSION, 0.26455 lb

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8)

Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: -, Option 2: -, Option 3: -

N01 NPT1 /8 (With M5 female thread) ZSM Connector for PSE200 1 pc. ZS-26-E-4 R04 4 plug-in reducer Connector for PSE300 1 pc.

(ZSE/ISE30A) P Reduction in setting w Reduction in setting work ork P Pre Prevention of mistakes in setting vention of mistakes in setting P Reduction in setting work P Prevention of mistakes in setting Cop Copy Copy 1 switch Slave pressure switch Master pressure switch (source of copy) 2 switches 10 switches 3-step setting -step setting 3-step setting 1 2 3 Push Push Adjust to the set-value

This is a legacy product, and replaced byISE30A-N01-P-L, PRESSSURE SWITCH *LQA, INSTRUMENTATION, ISE30/ISE30A PRESSURE SWITCH, CB, ISE30 1/8 INCH NPT VERSION, .59355 lb

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: A1 (Bracket A, Vertical Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)