SMC Corporation of America
Elite Part Number Search
Search Results "ISE2-T1-55"

Connector block assembly (For 9 to 17 stations (T1) terminal block) t-6 SX5000-64-8A SX3000-64-8A M3 x 30 (Matt nickel plated) SX3000-22-2 (M2 x 24) SX5000-57-6 Round head combination screw y Gasket DIN rail SX3000-57-4 VZ1000-11-1u i Refer to page 1-6-77. Note) The numbers t1 to 4 are for 24 VDC. For 12 VDC, suffix -12V to the parts no.

Example of the conventional measurement units (Reference) Unknown 6.0C 20C 26C 1.2 m3/h Fluorinated fluid Density : 1.80 x 103 kg/m3 : Unknown : 6.0C (6.0 K) : 20C (293.15 K) : 26C (299.15 K) : 20 l/min : Fluorinated fluid Density : 1.80 x 103 kg/m3 Heat generation amount Q Circulating fluid temperature difference T (= T2 T1) Circulating fluid outlet temperature T1 Circulating fluid return

NBR JIS B 2401.P12 q Seal 10 x t1 Fluororesin NBR Fluororesin Nylon Fluororesin Fluororesin (Antistatic specifications) Nylon Fluororesin Nylon Fluororesin 101 x t2 98 x t5 w Gasket e Seal Note 3) 23 x t1 r Seal 10 x t1 t Seal 20 x t1 Note 1) The quantity used for 1 filter is 1 each for the following seals, gaskets and O-rings.

LVQ6m only Nil M R N LQ1 integral fitting LQ1 integral fitting Threaded Threaded Connection tubing O.D. 1/8" (3) Connection tubing O.D. 4 Rc 1/8 NP T1/8 P v v Option (1) Valve type 6 7 8 9 24 Nil 1 2 3 4 5 None With flow rate adjustment With bypass High back pressure with flow rate adjustment High back pressure with bypass 0 1 2 N.C. N.O.

Change circulating fluid setting temperature.Set the pump output (option T1 only).

) 15 Solid State (NPN) 16 Solid State (NPN) 17 Solid State (NPN) 18 Solid State (NPN) 19 Solid State (NPN) 55 Solid State (PNP) Courtesy of Steven Engineering, Inc. !

or less Exhaust Center NVFS5400 55 or less 3 Position Pressure Center NVFS5500 55 or less Perfect (Double Check) NVFS5600 60 or less T E C H N I C A L SPECIFICATIONS O P T I O N A L T E C H N I C A L SPECIFICATIONS S T A N D A R D Pilot Type External Pilot Type Fluid Air and Inert Gas Manual Override Main Valve Direct Manual Override Type Max Operating Pressure 150 PSI (1MPa) Pilot Operator

Option symbol T1 Inverter Pump Mounted HRR010 20 T1 Inverter pump mounted Possible to choose an inverter pump in accordance with users piping resistance Cooling capacity will decrease by heat generated in the pump. The inverter pump does not use a mechanical seal. The 50 Hz and the 60 Hz inverter pumps have the same capacity.

. /. 53 14 /. 54 141. . 54 142. 55 143. . 56 144. . 57 145. . 58 146. . 58 15. . 59 15.1. /. 59 15.2 . 59 15.3. 61 15.4 . 61 15.5 . 62 15.6 . 62 15.7 . 62 16. . 63 16.1 . 63 16.2 . 65 3 - LECA6 Series/ 1.

. /.53 14 /.54 14.1 .54 14.2 .55 14.3 .56 14.4 .57 14.5 .58 14.6 .58 15. .59 15.1. /.59 15.2 .59 15.3 .61 15.4 .61 15.5 .62 15.6 .62 15.7 .62 16. .63 16.1 .63 16.2 .65 3 - LECP6 Series/ 1.

T1 (Terminal block of 1 row): 1-4 stations T2 (Terminal block of 2 rows): 5-8 stations T1 and T2 can be optionally chosen by adopting the combinations of single and double wiring(option spec.)etc.

Part No:LEC-W2 Teaching box (with 3m cable) Part No:LEC-T1-3EG (*1) These items are included when it is selected by ordering code. (*2) The controller setting software must use the latest version.

, T1 = 297 5K, 0.07 bar P 0.14 bar.

,T2Inverter pump 6.3.1 Option T1, T2Inverter pump With option T1 or T2, the pump output set value can be changed.

Average suction flow rate V x 60 T1 V x 60 T1 Q = Q = + QL T2 = 3 x T1 T2 = 3 x T1 Q : Average suction flow rate /min (ANR) V : Piping capacity () T1 : Arrival time to stable Pv 63% after adsorption (sec.) T2 : Arrival time to stable Pv 95% after adsorption (sec.) QL : Leakage at work adsorption /min (ANR) 2.

Typ. 7/8 1 5/64 5 8 Hex 3/8 1 3/32 1 7/16 5/8 7/8 11/16 40 1/8 T2 1/2 1/8 T2 1/8 T4 1/8 T6 1/8 T3 1/8 T1 1/8 T5 1/8 T8 1/8 T4-90 1 1/16 Note: Reducing Tees available with other barb combinations #1 7/8 17 32 7 16 7 16 Hex Typ. 27 32 #3 1 3/32 3/4 3/8 Typ. 7/8 9 16 7 16 #2 #4 27/32 3/4 41 1/8 T2 x 3 1/8 RT3 x 1 1/8 T3 x 3 1/8 T1 x 3 1/8 T4 x 3 1/8 RT4 x 2 7/16 7/16 17/32 9/16 19/32

JOG and constant rate movement, return to origin, test drive and testing of forced output can be performed. 569 B LEC Series Teaching Box/LEC-T1 RoHS How to Order LEC T1 3 J G Enable switch (Option) Enable switch Teaching box Nil None S Equipped with enable switch Cable length [m] 3 3 Interlock switch for jog and test function Stop switch Initial language Stop switch J Japanese E English

ALARM and ESTOP are expressed as negative-logic circuit. 55 Series LECP6 Options [Actuator cable] Controller side LE-CP/Cable length: 1.5 m, 3 m, 5 m 1 3 5 (Terminal no.)

Communication is interrupted. 5. 4 CN2: PC/TB connector The connector which connects the tools teaching box (LEC-T1-3*G*) or PC (LEC-W2) for setting the controller (LEC.