Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa/psi Dual Scale
Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.6 MPa, Lead Wire Length: 0.5m, Pressure Unit of the Scale Plate: MPa/psi Dual Scale
Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa
Style: Pressure Switch w/ T-Spacer, Body Size: AC30, Thread Type: NPT, Port Size: 1/8, Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: 3m, Pressure Unit of the Scale Plate: MPa/psi Dual Scale
(kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 100 0 20 40 60 80 100 120 57.0 100 95 90 85 80 75 70 65 60 Flow rate (l/min (ANR)) VAC side pressure (kPa) IRV3000 IRV3000 0 53.0 10 53.5 20 54.0 SET side pressure (kPa) 30 Set pressure (kPa) 54.5 40 55.0 50 Set point 60 55.5 70 56.0 80 56.5 90 57.0 100 95 90 85 80 75 70 65 60 100 0 20 40 60 80 100 120 140 160
Weight (g) d T H D1 D2 D3 L1 L2 L3 Model AK 1/8" ASD230F-U10/32-01 8.4 12 10-32 UNF 12.9 8 25.5 22.2 28.6 25.8 29.4 11.7 28.3 10 17.5 7.8 9.6 25 5/32" ASD230F-U10/32-03 9.3 13 ASS 20.7 7.8 16.5 15 3/16" ASD230F-U10/32-05 10-32 UNF 8 9.6 10 11.7 28.3 25.5 28.6 25.8 25 22.2 35.2 23.3 11.4 13.5 13 1/4" ASD230F-U10/32-07 32.6 12 ASR 30 16.5 14 3/16" ASD330F-N01-05S 39.5 39.6 23.9 11.6 34.6 17
AV Regulating pressure range AU Ambient and operating temperature range Weight AF Model AR Port size Model IR IN OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 Rc 1/8 VEX NPT 1/8, M5 x 0.8 NPT 1/8 4 One-touch fitting AMR R 1/8, M5 x 0.8 6 One-touch fitting NPT 1/8, M5 x 0.8 5/32" One-touch fitting ITV 1/4" One-touch fitting JIS Symbol
AS Weight (g) d T H D1 D2 D3 L1 L2 L3 Model 1/8" ASN ASD230F-U10/32-01 8.4 12 10-32 UNF 12.9 8 25.5 28.6 22.2 25.8 29.4 9.6 10 11.7 7.8 28.3 17.5 25 5/32" ASD230F-U10/32-03 9.3 13 3/16" AQ ASD330F-N01-05S 16.5 11.6 34.6 39.5 14 39.6 23.9 30 1/4" NPT1/8 ASD330F-N01-07S 17 13.2 42.2 25.6 12.7 36.1 27 31.1 14.2 11.8 10.6 32 33.9 38.9 15.8 31 5/16" ASV ASD330F-N01-09S 18.5 15.2 44.8 28.2 1/4"
2030 10 1% * -7No.PS-OMG0005CN-E 0 01 28 C2 PSE56 0 (01MPa) (1) C2 1 (0-101kPa) 3 (-100100kPa) *PSE200 4 (0500KPa) (15V) 01 R1/8(M5) 28 (420mA) 02 R1/4(M5) C01 Rc1/8 N01 NPT1/8(M5) N02 NPT1/4(M5) A2 URJ1/4 B2 TSJ1/4 ZS-28-C 1 Rc1/4 ZS-31-X175 1 NPT1/4 ZS-31-X186 1 Rc1/8 ZS-31-X188 1 NPT1/8 ZS-31-X189 1 15[V]F.S.=514[V] (1F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1K 1M A/D 5V A/D
We guarantee that the product complies with the outline dimensions provided. d.
lhe body D-97 Contact Protection Box a D-9 type switches have no internal conlact proteclion cicuit.
lhe body D-97 Contact Protection Box a D-9 type switches have no internal conlact proteclion cicuit.
AV Regulating pressure range AU Ambient and operating temperature range Weight AF Model AR Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Port size Model IR IN OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 Rc 1/8 R 1/8, M5 x
Ejector mounting position ZZYX3 45T U side D side U D J Mounting position of connector Number of ejectors 1 to 3 stations A, B port size (Valve only) U side D side U D C4 C6 4 One-touch fitting 6 One-touch fitting Mixed M SUP/EXH block assembly mounting position Total number of ejector/valve stations U D side D B U side When creating the mixed specifications, complete the stations table on
AN200 to 900 1 Model 0.5 A B D Dimensions (mm) Model Port size R Weight (g) Recommended flow (m3/min (ANR)) 3 or less 5 or less 8 or less 12 or less 20 or less 30 or less 50 or less 80 or less Effective area (mm2) 35 60 90 160 270 440 590 960 2 0.2 Inlet pressure (MPa) Noise level (dB) (A) 0.1 1 4 AN200-02 17 63 22 19 25 84 25 22 35 92 30 27 165 107 46 36 225 132 50 41 490 200 74 55 580 233
www.stevenengineering.com I 6.16 VACUUM VACUUM PADS SERIES ZP ZP SERIES VACUUM PADS 288 Standard Options 12 Diameters 4 Types 6 Materials D I M E N S I O N S ZP VA C U U M PA D S D I M E N S I O N S ZP VA C U U M PA D S D I M E N S I O N S ZP VA C U U M PA D S F L AT T Y P E PA D Part No Type A C B D E F Y ZP02U U02 2 2.6 1.2 7 12 0.8 ZP04U U04 4 4.8 1.6 7 12 0.8 D E E P T Y P E PA D ZP06U
Model Max. rated flow Model Max. rated flow [L/min] [L/min] PFM710--C/E 10 (5) PFM710--D/F 10 (5) PFM725--C/E 25 (12.5) PFM725--D/F 25 (12.5) PFM750--C/E 50 (25) PFM750--D/F 50 (25) PFM711--C/E 100 (50) PFM711--D/F 100 (50) : ( ): Fluid: CO2 : ( ): Fluid: CO2 Flow adjustment needle revolution Flow characteristics (reference value) -57No.PF-OMJ0006-J Pressure loss (at 350 [kPa]) -58No.PF-OMJ0006
The signal has to be converted by a A/D converter for pressure display or switch output. Current Output signal is a current signal in the range of 4 to 20[mA]. The signal is transformed into a voltage signal before being converted by a A/D converter for pressure display or switch output.
Gauge Adaptor (w) P30501 056 NPT Run Tee fitting gauge installation (90") Gauge Adaptor (Y) P30501 057 Branch Tee fitting gauge installation (90") I For SlG, pressure range 0-30psi, 1/8 NPT G43-P2-N01 or KS1OB.SD2 (St. Steel) Pressure Gauge For OUT 1, OUT 2 pressure range 0-150 psi, 1/8 NPT G43-P10-N01 or KSlOB-AD11 (St.
Gauge Adaptor (w) P30501 056 NPT Run Tee fitting gauge installation (90") Gauge Adaptor (Y) P30501 057 Branch Tee fitting gauge installation (90") I For SlG, pressure range 0-30psi, 1/8 NPT G43-P2-N01 or KS1OB.SD2 (St. Steel) Pressure Gauge For OUT 1, OUT 2 pressure range 0-150 psi, 1/8 NPT G43-P10-N01 or KSlOB-AD11 (St.