W W D E d M a MA Q C A K F NA NB B H S + Stroke M ZZ + Stroke With rod boot e 10 l f h + l ZZ + l + Stroke (mm) Bore size (mm) A a d B C F G GA GB K M MA NA NB R S Q V W T P J MM E D 0 0.018 0 0.021 0 0.021 0 0.021 0 0.025 0 0.025 0 0.025 0 0.062 0 0.062 0 0.074 0 0.074 0 0.074 0 0.074 0 0.087 40 17 45 23 10 60 17.5 M8 x 1.25 18 M14 x 1.5 7.5 8 44 18 9.5 13 11 25 20 1/4 14 30 22 37 106 5
It is already built into the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry D With connector DIN terminal (Type D) DC specifications of type D and DO are only available with 12 and 24 VDC. Power saving circuit is not available for D or DO types.
V 564 H 364 K 332 J 116 J 116 J 116 V 564 J 116 K 332 V 564 V 564 V 564 K 332 K 332 K 332 Model LW53 3 Way Normally Closed Piped Exhaust LW53GG8XGB LW53GH8XGB (G or L) LW53GJ8XGB (G or L) LW53GV8XGB (G or L) LW53GK8XGB (G or L) LW53HH8XGB (G or L) LW53HJ8XGB (G or L) LW53HV8XGB (G or L) LW53HK8XGB (G or L) LW53JJ8XGB (G or L) LW53JV8XGB (G or L) LW53JK8XGB (G or L) LW53VV8XGB (G or L) LW53VK8XGB
It is already built-in to the rectifier circuit. 2 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 3 Electrical entry 4 220 VAC 50/60 Hz [230 VAC 50/60 Hz] D With connector DIN terminal DO Without connector DC specifications of type D and DO is only available with 12 and 24 VDC. Power saving circuit is not available in the case of D or DO type.
Stopper (mm) Adjustment bolt Model Stroke adjustment range L L CY1H10, CY1H15, 0 to 15 CY1H20 CY1H25, CY1HT25, 0 to 30 CY1HT32 57 58 Series CY1 Auto Switch Specifications Auto switch application table Auto switch part number Cylinder model CY1R CDY1S CY1L CY1H D-A72, D-A73, D-A80 Reed switches Solid state switches D-A72H, D-A73H, D-A76H, D-A80H D-A73C, D-A80C Note 1) D-A90, D-A93, D-A96
11 L 11 L (SOL1) L+ 12 13 L+ 12 NOTE 8 (SOL2) Ex i Barrier 13 L+ (SOL PWR1) (SOL PWR2) TOP SW+ TOP SW BTM SW+ BTM SW Ui (Vmax) Ii (Imax) Pi (Pmax) Li Ci L 14 L 13 NOTE 8 L+ L 14 16 L+ 14 Uo (Voc) Ui (Vmax) Io (Isc) Ii (Imax) Po Pi (Pmax) 15 L 15 16 L+ L+ 16 17 L L+ 18 Notes 1.
60, 70, 80, 90, 100 Weight/( ): Denotes the values with D-A93.
Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.
50 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 45 (n 2) (n = 2, 3, 4, 5) MB MB1 D-H7 D-H7W D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 45 (n 2) (n = 2, 3, 4, 5) CA2 CS1 D-H7C D-C73C D-C80C 5 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 65 + 50 (n 2) (n = 2, 3, 4, 5) CS2 D-G5 D-K59 D-B5 D-B64 5 15 75 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 75 + 55 (n 2) (n = 2, 3, 4,
side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)
Applicable fitting size Noise reduction (dB) Effective area (mm2) (Cv factor) Series Model A L D d D VQ2000 10 AN20-C10 36.5 57.5 30 16.5 30 Elbow fitting assembly VVQ2000-F-L(C4/C6/C8/N3/N7/N9) It is used for piping that extends upward or downward from the manifold.
It is already built-in to the rectifier circuit. 50 60 100 VAC Hz 1 2 200 VAC Hz 50 60 50 60 110 VAC Hz [115 VAC Hz] 3 Electrical entry 50 60 50 60 50 60 DIN terminal D With connector 4 220 VAC Hz [230 VAC Hz] DO Without connector DC specifications of type "D" and "DO" is only available with 12 and 24 V DC. Power saving circuit is not available in the case of "D", "DO" type.
Class E or equivalent (120C) (5) 4.5 VA/50 Hz, 4.2 VA/60 Hz 3.5 VA/50 Hz, 3 VA/60 Hz 1.8 W Plug-in type (FZ) Non plug-in type Grommet (G), Plug connector (L, M, KZ) DIN terminal (D) Inrush Holding Apparent power (AC) Power consumption (DC) Electrical entry Note 1) Use dry air at low temperatures.
30 Rod end nut (Standard) Knuckle joint pin Clevis pin 2-d d Dd9 D C L l m H B Note 1) d (Through hole diameter) Bore size (mm) Clevis Knuckle Part no.
Size M4 x 0.7 x 8 L Q'ty 1 BTBT-03, BT-04, BT-05 BT-06, BT-08, BT-12 D-A5, A6 D-F5, J5 D-Z7, Z8 D-Y5, Y6, Y7 BA4-040, BA4-063, BA4-080 BMB4-032, BMB4-050 2 Set screw M4 x 0.7 x 6 L 2 BMB5-032 BA7-040, BA7-063, BA7-080 D-A9 D-M9 BBA1 D-A5, A6 D-F5, J5 BT-16, BT-18A, BT-20 BS4-125, BS4-160 BS4-180, BS4-200 BS5-125, BS5-160 BS5-180, BS5-200 D-Z7, Z8 D-Y5, Y6, Y7 3 Set screw M4 x 0.7 x 8 L 2
The angle is 60 when any of the following auto switches are used: D-90, D-90A, D-97, and D-93A. The angle is 69 when any of the following auto switches are used: D-S99(V), D-T99(V), and D-S9P(V) 3.
m 1000 L1 a = 3000 0 20 40 60 Transfer load m (kg) 600 L2 400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 20 40 60 m Transfer load m (kg) 2000 a = 1000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 20 40 60 Transfer load m (kg) Refer to page 145 for deflection data. 60 61 Non-standard Motor/Horizontal Mount Specification Series LJ1H30 Dimensions/LJ1H303PD(X10) Scale: 10% 8H10 depth 10 4-M8 x
90, D-90A, D-S99(V), D-T99(V), and D-S9P(V) The length is 30 when any of the following auto switches are used: D-97 and D-93A 2 The angle is 60 when any of the following auto switches are used: D-90, D-90A, D-97, and D-93A.