SF and BF Indicators Yes Over current detection 2 DI (Input signal "n+4") FS LED 3 1 BF SF Description 3 0V (US1) Fieldbus Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
PROFIBUS communication is abnormal GW unit BF LED is ON Set within the range 0 to 125. Check the operation manual for the PLC. Check the address setting. Check the settings of the PLC. Check that there is no high voltage cable or equipment that generates noise around the communication cable. Separate the communication cable away from noise sources.
MOD/NET BF ON for BUS abnormality. GREEN ON: Connection established (on line). RED BLINKING: Connection time out (minor communication abnormality).
V +24 V for SI unit operation LED Description 8 Mounting hole Mounting hole for connection to the valve manifold SI0 V 0 V for SI unit operation 4 SF System fault 5 Unused Accessories BF BUS fault Hexagon socket head cap screw 2 pcs.
Check the number of input/output is set correctly. 1 BF LED is lights up Check the power for output (24 VDC) is powered at a specified voltage. Check the power supply voltage for output is above 20 V. Check the input unit is connected after the input port. 2 DIA LED is lights up : Refer to "Operation Manual" for detail of troubleshooting. 22
MOD/NET BF ON for BUS abnormality. GREEN ON: Connection established (on line). RED BLINKING: Connection time out (minor communication abnormality).
MOD/NET BF ON for BUS abnormality. GREEN ON: Connection established (on line). RED BLINKING: Connection time out (minor communication abnormality).
The HF2-BF series currently includes port sizes of 1/4, 3/8, and 1/2 with flow rates up to 800 L/min.
The HF2-BF series currently includes port sizes of 1/4, 3/8, and 1/2 with flow rates up to 800 L/min.
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.6999 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.08475 lb
Output restriction w/pilot valve, fork lever joint, compensation spring, w/external scale plate, IP8000/8100 NO SIZE PT VERSION, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 5.73201 lb
BASE SEAL (IP8000/8100), BASE SEAL (IP8000/8100), INSTRUMENTATION, IP8000/8100 POSITIONER, 21, IP8000/8100 NO SIZE RATING, .94600 lb
COVER SEAL (IP8000/8100), COVER SEAL (IP8000/8100), INSTRUMENTATION, IP8000/8100 POSITIONER, 21, IP8000/8100 NO SIZE RATING, .94600 lb
Functions LED Condition condition PWR Green On Supply of power BUS STAT Green Controller IF is communicating flashing ALM Green No alarm flashing CN2 STAT Off CN2 (TB/PC terminal) invalid SF Green On System fault normal BF Green On BUS fault normal Refer to 10. LED display for the explanation of LED lamps.
LEC Series Modbus LE Series Modbus 7 - 24 () 1 1 LECGPR1 1 2 3.4 3LEC LEC 4. 4 LEC 4 LEC 4 5 CN1~CN3 5. 8 - 6 DC24V LEC LEC LEC 12.4 LED LED PWR CN2 STAT CN2TB/PC BUS STAT IF ALM SF BF LED 10.LED ALM LED 7 12.LEC 9 - 3 31 DC24V10% 200mA 300mA LEC 5 57words 57word UL , UL1310 Class2 Profibus Profibus DP V1 DP slave 0125 ID 1414 GSD Dsub 9.6k 19.2k 45.45k
Connector for Communication Connector for Power supply RUN LED DIA LED BF LED The line color is when the optional cable is used. Connection to external equipment LED INDICATION Communication wiring Power supply wiring 1:No Connect 1:VCC 2:RxD/TxD_N Power DC24V 2:F.G.
BH BI (UU) 2-M3 x 0.5 (opposite side, same location) (For front port, use hexagon socket head set screw) Q H 2-J through JA depth of counter bore JB (opposite side, same location) 1.5 S BE CA CB BF DD D BD BG A 2.2 (0.4) Note 1) SD 16 BA 2-M3 x 0.5 depth 4 BB W 2-M3 x 0.5 (For side port, use hexagon socket head set screw) N BC Note 2) For the 180 specification, the slated line area do not
, 1 pc., 54 mm is added per 1 pc. 9 288 423 10 313 448 7 238 373 11 338 473 6 213 348 12 363 498 5 188 323 13 388 523 4 163 298 14 413 548 3 138 273 15 438 573 8 263 398 L1 L2 2 113 248 16 463 598 Indicator Unit (LED) Descriptions and Functions SI Unit (DeviceNet) SI Unit (PROFIBUS-DP) Input block 1 3 5 7 PWR 0 2 4 6 TM TM PWR(V) RUN PWR(V) MOD/NET PWR ADDRESS 1 H L 4632 SETTINGS DIA BF