Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Fluid Fill Port, Manual Fill
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Earth Leakage Breaker
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Fluid Fill Port, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: w/Caster Adjuster-foot, UL Certification: -, Option 2: -
Cooling Capacity: 100, Thread Type: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 46 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], Option 1: A + K, UL Certification: None, Option 2: SI Unit Only
AS ASP ASN AQ ASV Dimensions AK Universal type Weight (g) T H1 H2 D1 D2 D3 L1 L2 L3 L4 L5 A M1 Max. Min. Max. Min.
AS1200-M3 AS1400-M3 AS120-M5 AS220-01AS220-02 AS320-03 AS420-04 10-32UNF Port size M3 x 0.5 2.5, 4, 6 1.05 MPa 0.7 MPa 0.1 MPa M5 x 0.8 1/8 1/4 20, 25, 32, 40 3/8 1/2 6, 10, 15, 20, 25 80, 100 32, 40, 50, 63 Applicable cylinder bore size (mm) 1.5 MPa 1 MPa 0.1 MPa Proof pressure Max. operating pressure Body swivels 360 Swivel type allows free setting of piping.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
Metric size Inch size With One-touch fitting 04 06 08 10 12 01 03 05 07 09 11 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" Thread type Nil Metric thread (M5) Unified thread (10-32 UNF) R NPT AS N ASP Bore size ASN M5 U10/32 01 02 03 04 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 AQ ASV AK ASS Needle Valve/Flow Characteristics (Inlet Pressure: 0.5 MPa) ASR ASD230F ASD330F ASD430F ASF 100 200 400 1.5
Millimeter Inch With One-touch fittings 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 01 03 05 07 09 11 4 6 8 10 12 04 06 08 10 12 Thread _ Meter thread (M5) Unified thread (10-32 UNF) R(PT) N NPT Port size M5 X 0.8 10-32UNF 1/8 1/4 3/8 1/2 M5 U10/32 01 02 03 04 AS ASN AQ ASV Needle Valve/Flow Characteristics AK ASD230F ASD330F ASD430F ASS 100 200 400 1.5 6 3 07, 08, 09, 10, 11 Effective area (mm2) Flow
ASN AQ ASV Flow Rate and Sonic Conductance Symbol AK AS221F-01 AS121F-M5 AS221F-02 AS321F AS421F Model Tubing O.D.
To avoid such dangers, HRS100/150 series thermo-chillers can be set to continue or stop operation at the time of alarm generation.
The default setting for alarm code “AL09” is to stop operation safely (Note 3).
If this function has been activated, check the following.
① Check whether the level gauge on the tank is below the “Low” level.
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 100 (10 kW), Cooling Method: A (Air-cooled), Pipe Thread: F (G, w/Rc-G Conversion Fitting), Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)]
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: NPT, w/Rc-NPT Conversion Fitting, Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz)], Option: -