Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.Electro pneumatic regulator, Step-less control through electric signals, Simple circuit configuration, Internal or external pilot available, Base mounted or body ported styles, HYBRID REGULATOR, VALVE, VY1 E/P REGULATOR, MA, VY1 BASE MT Weight: tab 9
Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.Electro pneumatic regulator, Step-less control through electric signals, Simple circuit configuration, Internal or external pilot available, Base mounted or body ported styles, HYBRID REGULATOR, VALVE, VY1 E/P REGULATOR, MA, VY1 BASE MT Weight: tab 9
Using the VVEXB/2/4 series, a maximum 10 station manifold is possible.Electro pneumatic regulator, Step-less control through electric signals, Simple circuit configuration, Internal or external pilot available, Base mounted or body ported styles, HYBRID REGULATOR, VALVE, VY1 E/P REGULATOR, MA, VY1 BASE MT Weight: tab 9
.. 24 17.5 4.5 M22x l .5 19 5 24 I ~ 17 13.5 , 10.5 ~ 10. 23.5 20 . 15 3Q,5 27 17 3.5 M15x l.S 12 4 10 . 24 5 19 14.5 11.5 15 10 25 20.5 15 31.5 27 ~. .. ~ '. ar. ' Panel Mount Type: CJPB NN Exhaust ~ Bore4>6:CO.5 \ \ 4>10. 1S:Cl ~, .. " ~.
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT, VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2F, SYJ5000 BASE MT NO SIZE RATING, .40417 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2E, SYJ5000 BASE MT NO SIZE RATING, .41764 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, SGL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2D, SYJ5000 BASE MT NO SIZE RATING, 0.1575 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2E, SYJ5000 BASE MT NO SIZE RATING, .29826 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2F, SYJ5000 BASE MT NO SIZE RATING, .15211 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2F, SYJ5000 BASE MT NO SIZE RATING, .00000 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2F, SYJ5000 BASE MT NO SIZE RATING, .18373 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2G, SYJ5000 BASE MT NO SIZE RATING, .00000 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2G, SYJ5000 BASE MT NO SIZE RATING, .00000 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2G, SYJ5000 BASE MT NO SIZE RATING, .00000 lb
Fluid: air , Operating pressure range (MPa): 0.15 to 0.7 , Ambient and fluid temperature: -10 to 50° C (no freezing) , Maximum operating frequency: 10Hz, VALVE, DBL SOL, BASE MT (DC), VALVE, SYJ5000 SOLENOID VALVE 5/PORT, 2G, SYJ5000 BASE MT NO SIZE RATING, .00000 lb