SMC Corporation of America
Elite Part Number Search
Search Results "G46E-7-02-C2"

Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Size: 46 (42.5 O.D.), Display Pressure: 10 (1.0MPa), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten)

Size: 46 (42.5 O.D.), Display Pressure: P10 (1.0MPa, 150psi), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten), Option: X30 (Both MPa and psi)

Size: 46 (42.5 O.D.), Display Pressure: P2 (0.2MPa, 30psi), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten), Option: X30 (Both MPa and psi)

Size: 46 (42.5 O.D.), Display Pressure: P4 (0.4MPa, 60psi), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten), Option: X30 (Both MPa and psi)

Size: 46 (42.5 O.D.), Display Pressure: 2 (0.2MPa), Connection Thread: 02 (R 1/4), Clear Cover Material: Polycarbonate, Attachment: C2 (Clear Cover Removable, Wrench Tighten)

KQSY10-C4-X1336 (JSY1000) KQSY11-C6-X1336 (JSY1000) KQSY30-C8-X1336 (JSY3000) KQSY50-C12-X1336 (JSY5000) * It is not possible to replace C2 or C4 fittings with C6 fittings for the JSY1000 series. * Refer to page 18 for One-touch fitting, clip, and port plate part numbers. 15 No.JSY1000V-OMW0004-A JSY1000/3000/5000 series Specific Product Precautions 7 Be sure to read this before handling.

Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no. NDd9 NDH10 NX R1 U1 Y-J010C 3.30.030 0.060 3.3+0.048 0 3.2 8 10 NTJ-015C 16 8 9.2 M5 x 0.8 4 Y-J016C 50.030 0.060 5+0.048 0 6.5 12 10 * A knuckle pin and retaining rings are included.

(If m otor option is with lock, lo ck ca ble is also include d.) 200 to 230 LECSC2-S C2 S1 LECSS1S 100 to 120 *6 The standa rd direction of each c a ble is shaft side(A)..

Devise a safe system so that if a person engages the emergency stop or if a safety device is tripped during a system malfunction,such as a power outage, the operation of the magnet gripper will not cause a hazard to humans or damage the equipment. 7. Consider the action when operation is restarted after an emergency or abnormal stop.

Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function P-1 C-5 C-5 (P-3) (Differential) Pressure This function clears and resets the zero value on the display of measured (differential) pressure within 7%F.S. of the factory adjusted value.

Set value correction by auto shift function Supply pressure normal Supply pressure drop Supply pressure increase F Reset function This function clears and resets the zero value on the display of measured (differential) pressure within 7% F.S. of the factory adjusted value.

(Nm) L(mm) MHM-16D M3x0.5 0.63 6 MHM-25D M4x0.7 1.5 8 MHM-32D M5x0.8 3 10 MHM-50D M6x1 5.2 12 (N) MHM-16D 100 MHM-25D 200 MHM-32D 300 MHM-50D 500 -7- 2-3. 40 2-4. () 5 5 P-01-11 -8- 2-5. 1.52 2-6. 1 ()ISO VG320 (SDS) -9- 2-7. 1) 1) 2) 3) 12mm -10- 2 C3 C1 C2: C3 D-M9V D-M9WV D-M9AV D-M9 D-M9W D-M9A D-P3DWA A B E G A B E G L A B E G L D F H MHM-16D 9.1 9.1 5.6 4.6 8.1 12.8 11

Cable type 5, 6, 7 Cable length [m] 5, 8 Driver type 5 I/O connector Nil H Without connector With connector Nil A1 A2 B1 B2 C1 C2 S1 S2 Nil S R Nil 2 5 A Without cable 2 m 5 m 10 m Without cable Standard cable Robotic cable (Flexible cable) Power supply voltage (V) Compatible drivers 100 to 120 200 to 230 100 to 120 200 to 230 100 to 120 200 to 230 100 to 120 200 to 230 Without driver LECSA1