Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Attachment: Clear Cover Non Removable, Wrench Tighten, Option: Nickel Plated
Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Attachment: Clear Cover Removable, Wrench Tighten, Option: Nickel Plated
Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Attachment: Clear Cover w/Protrusion, is Removable, Option: X4 [Oil-free (Wetted Parts Degrease Washing)]
Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Attachment: Clear Cover w/Protrusion, is Removable, Option: Nickel Plated
Pressure Gauge: ø42 Outside Diameter, Back Side Thread, Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Attachment: Clear Cover Non Removable, Wrench Tighten, Option: X4 [Oil-free (Wetted Parts Degrease Washing)]
Display Pressure: 1.0MPa, Connection Thread: R 1/4, M5 Female, Grade: Precision Cleaning, Clean Room M5.5, Attachment: Clear Cover w/Protrusion, is Removable
Display Pressure: 10 (1.0MPa), Connection Thread: 02M (R 1/4, M5 Female), Grade: SRA (Precision Cleaning, Clean Room M5.5), Attachment: C (Clear Cover Non Removable, Wrench Tighten)
Display Pressure: 10 (1.0MPa), Connection Thread: 02M (R 1/4, M5 Female), Grade: SRA (Precision Cleaning, Clean Room M5.5), Attachment: C2 (Clear Cover Removable, Wrench Tighten)
SMC offers a variety of pressure gauges?including general purpose,?oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.? Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.? Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ?3% F.S. (full
SMC offers a variety of pressure gauges?including general purpose,?oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.? Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.? Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ?3% F.S. (full
SMC offers a variety of pressure gauges?including general purpose,?oil-free/external parts copper-free with limit indicator, clean series and a pressure gauge with a pressure switch.? Pressure ranges vary from 0 to 1.5MPa, depending on the selected gauge.? Panel mounting is possible.General purpose gauge w/limit indicator , Back or vertical side thread , Indication precision: ?3% F.S. (full
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, 0.43434 lb
Optional Parts ARP20(K) ARP30(K) ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G36-4-01 G46-4-02 Round type Note 2) 0.4 MPa Square embedded type Note 3) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] G36-2-01 G46-2-02 Round type Note 2) 0.2 MPa Square embedded type Note 3) GC3-2AS [GC3P-010AS (Pressure gauge cover
Optional Parts ARP20(K) ARP30(K) ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G36-4-01 G46-4-02 Round type Note 2) 0.4 MPa Square embedded type Note 3) GC3-4AS [GC3P-010AS (Pressure gauge cover only)] G36-2-01 G46-2-02 Round type Note 2) 0.2 MPa Square embedded type Note 3) GC3-2AS [GC3P-010AS (Pressure gauge cover
・While it is possible to mount a G36-10-01 or G46-10-01 pressure gauge on a VEX113□/123□ series regulator, it will be larger than the width of the product body.
・It is also possible to mount a G46-10-01 pressure gauge on a VEX133 □ series regulator so long as it does not interfere with the piping.
Mtrual opralor assmbly $llh Odng PA0@1 PBO{01 I 1 Raplacdr3nl coll only-4.C. sol6nold 1Al0 aot@ 1O/@ cl2A{9 cl2A-10 cl2A.1t 10 I Sol6noi, aBsmbly-4,C. conplst wllh coll, 120/ao 24(m0 a0,t0 @14O9 @ta-10 cora-1t At2A{9 412A,10 1 l '| NXT01010 NXT0307.3 12 1 NXTO1G12 NXTO1G12 13 @t|vo scr6w .nd locl wa5hsr xTt)10-21 xT010.21 DIRECTIONAL AIR YALVE MANIFOLD ASSEMBLY SERIES NVS 3115, 3125 NVS 3135
G Description 04 06 10 02 03 04 02 03 04 VY110 0 1VY120 0 1VY130 0 1VY140 0 1VY170 0 11 1 0 2 VY190 0 11 2 4 0 VY1D00-M5 VY1A0 0 1-M5 VY150 0 1VY1B0 0 1M 0 5 1 01 02 01 02 PPA B VEX9-32A VEX5-32A VEX7-32A VEX3-32A VEXA-18-2A VEX1-18-1A Bracket (With bolt, washer) AL F VEX1-18-2A VEXA-18-3A G27-10-R1-X207 G G46-10-01 G36-10-01 G27-10-01 Pressure gauge AN120-M5 AN120-M5 Pilot EXH port silencer
Symbol Parts name VEX11001 02 VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 VEX3-32A VEX5-32A VEX7-32A VEX9-32A VEX1-18-1A G27-10-01 G36-10-01 B F G Bracket (with bolt and washer) Air operated External pilot solenoid G46-10-01 VEX1-18-2A Pressure gauge (1) Note 1) When requring the gauge except mentioned above, specify the model number.
G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.
Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020