SMC Corporation of America
Elite Part Number Search
Search Results "CY1L25H-800B-A73HL"

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1500 (15 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 4000 (40 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 4000 (40 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 32 (1 1/4 Inch), Magnetic Holding Force: L (Small Holding Force), Stroke: 4000 (40 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0500 (5 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0600 (6 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M, Number: 4 pcs.

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1500 (15 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 15 (5/8 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0200 (2 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 0400 (4 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 1500 (15 Inch), Adjuster: Adjuster Bolt, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2000 (20 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: B (Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 2500 (25 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: D (Built-in), Bore Size: 25 (1 Inch), Magnetic Holding Force: H (Large Holding Force), Stroke: 3000 (30 Inch), Adjuster: BC (Cap Type Shock Absorber (2 pcs.)), Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 125mm, Stroke: 100mm, Option: Rubber Bumper, Rod End Male Thread, Auto Switch: A73HL--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Horizontal, 3M, Number: -

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, IE, 25MM CY1H/CY1L DBL-ACT A/S, 11.34002 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)25CY1L25H18.50.65

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, IE, 25MM CY1H/CY1L DBL-ACT A/S, 10.14126 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)25CY1L25H18.50.65