70 75 80 F 50 50 50 60 35 60 70 75 80 GA 22 22 22 22 55 61 102 154 190 13-/22-MXS25-10 13-/22-MXS25-20 13-/22-MXS25-30 13-/22-MXS25-40 13-/22-MXS25-50 13-/22-MXS25-75 13-/22-MXS25-100 13-/22-MXS25-125 13-/22-MXS25-150 149 MXS Air slide table 1322Dimensions / MXS25 1322Axial piping (25) MXS25-P 132280.7 Maximum 11.5 35.5 Operating port 2-Rc, G, NPT1/8 40 18 20 Other dimensions are the same
Class B or equivalent (130C) Coil insulation 100 VA 50 Hz Inrush Symbol Specifications 90 VA 60 Hz AC Apparent power Note) -XA Change of rod end shape 20 VA 50 Hz Holding -XC4 With heavy duty scraper 14 VA 60 Hz Piston rod and rod end nut made of stainless steel Note) Power consumption 13.2 W DC -XC6 Note) At the rated voltage.
TF G 1/8 G 1/8 G 1/8 G 1/4 G 1/4 G 1/4 TN NPT 1/8 NPT 1/8 NPT 1/8 NPT 1/4 NPT 1/4 NPT 1/4 Nil M3 x 0.5 M5 x 0.8 M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/8 Rc 1/4 Rc 1/4 Rc 1/4 CY3B6 CY3B10 CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 CY3B50 CY3B63 25 30 35 50 50 50 60 60 70 10 16 19 25 30 40 40 60 70 16 16 78 81 103 132 137 156 182 180 192 d CYP C H B H 4 4 8 8 10 B 8 14 26 32 41 C 9.2 16.2 30 37 47.3 d M6 x 1.0
(Same side) 75+50(n2) n=2, 4, 6, 8 80+50(n2) n=2, 4, 6, 8 85+50(n2) n=2, 4, 6, 8 70 1 switch 75 80 85 1 switch, 2 switches (Different side, Same side) 80 95 105 110 60 D-A5 D-A6 60+55(n4)/2 n=4, 8, 12, 16 Other qty.
(Example) CDV3LN50-100-1 2 position single 2 position double Solenoid valve voltage Nil W 1 2 5 9 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Other Cylinder stroke (mm) (Refer to Standard Stroke on page 10-15-51.)
45, 60, 75, 100, 125, 150, 175, 200 Standard Non-lube Double acting Single rod 15, 30, 45, 60 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
M2 M3 m2 m3 16 20 25 32 40 50 63 16 20 25 32 40 50 63 6.0 3.0 1.0 18 7 2.1 10 5.2 1.7 26 10.4 3 15 9.0 2.4 38 15 4.5 MY1MW 30 15 5.0 57 23 6.6 59 24 8.0 84 33 10 115 38 15 120 48 14 140 60 19 180 72 21 6.0 3.0 2.0 18 7 2.1 10 5.0 3.0 25 10 3 15 8.5 5.0 35 14 4.2 30 14 10 49 21 6 MY1CW MY1B 60 23 20 68 30 8.2 115 35 35 93 42 11.5 MY1H 150 50 50 130 60 16 The above values are the maximum allowable
, 16 ) Note 2) 90 + 40 (n 4) 2 95 + 40 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 15 + 40 n (n = 2, 4, 6, 8 ) Note 1) (n = 4, 8, 12, 16 ) Note 2) 2 (Different surfaces, Same surface) 1 60 65 70 D-M9V D-M9WV (n 2) 2 10 55 55 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 60 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 65 + 30 (n 4) 2 70 + 30 (n 4) 2 (n = 4, 8, 12, 16 ) Note 2) 10 + 30 n (n = 2, 4, 6
Hz 200 VAC: 22.5/50 Hz, 21/60 Hz [ ] Start-up 4.5 to 50 Hz, 4.2/60 Hz Apparent power (VA) [Current: mA] (2) AC 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz [ ] Holding 3.5/50 Hz, 3/60 Hz DC: Diode, AC: ZNR Surge voltage suppressor Symbol Specifications CV -XA Indicator light DC: LED (Red), AC: Neon bulb Change of guide rod end shape Option Note 1) Impact resistance: No malfunction
Auto switches are shipped together but not assembled. 6 10 16 20 25 32 6 mm 10 mm 16 mm 20 mm 25 mm 32 mm Action D Double acting Port thread type Type M5 x 0.8 Rc1/8 NPT1/8 G1/8 Bore size 6, 10, 16, 20, 25 32 32 32 Symbol Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50, 60 5, 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 Nil TN TF Applicable Auto Switches/Refer
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
68 77 85 MGF 0UT 201 40 60 80 101 121 141 161 181 201 Symbol Specifications 16 8 MGZ IN 151 30 45 60 76 91 106 121 136 151 XA Change of rod end shape Heat resistant cylinder (10 to 150C) XB6 0UT 314 63 94 126 157 188 220 251 283 314 20 10 MGT XB9 Low speed cylinder (10 to 50 mm/s) IN 236 47 71 94 118 142 165 189 212 236 XB10 Intermediate stroke (Using exclusive body) 0UT 491 98 147 196 246
20 40 0 60 20 40 0 60 80 CY1F Moment (Nm) Moment (Nm) Moment (Nm) Note) Indicates the displacement (rigidity) on the slide table from the position where the reaction force is generated when the torque is applied to the slide table.
(Onty auto SWItch mounting bracket ISassembled at the lime of shipment) 2 Air Cylinder Series CS2 Specifications " Bore size (mm) 125 f 140 :1 1 60 . j Action Double actmg.
60 10 12 11 14 5 5 6 6 40 45 55 65 22 22 28.5 30 11 13 14 16 5 5 5 7 66 82 100 120 86 106 125 150 70.5 82.5 101 121 Other dimensions are the same as basic style.
Bore Size: 20mm, Thread: ø6-ø20 Bore: M Thread; ø25,ø32 Bore: Rc 1/8, Stroke: 60mm
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure