Guide Table Bore size/ Standard stroke (mm) Number of auto switches 40 63 100 30, 50, 75, 100 30, 50, 75, 100 30, 50, 75, 100 2 pcs. 1 pc. "n" pcs. Nil S n Auto switch Nil Without auto switch (Built-in magnet) Select applicable auto switches from the table below. Applicable Auto Switch/Refer to pages 1719 to 1827 for further information on auto switches.

) 5 (Z) Applicable load Type 1 (M) Special function Electrical entry Wiring (Output) DC AC Perpendicular In-line MGC 3-wire (NPN) M9N M9NV 5 V, 12 V IC circuit 3-wire (PNP) MGF M9PV M9P Reed switch Solid state switch Reed switch Solid state switch Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ MGZ 12 V 2-wire M9B M9BV

Speed [mm/s] 0 48 Operating humidity range [%RH] 90 or less (No condensation) Allowable external force [N] Note 8) 10 20 1 75 Motor size 56.4 Motor type Step motor (Servo/24 VDC) Electric specifications 2 100 3 150 Encoder Incremental A/B phase (800 pulse/rotation) 4 200 Rated voltage [V] 24 VDC10% 5 250 Power consumption [W] Note 3) 50 52 6 300 Standby power consumption when operating [W

Standard Strokes Bore size [mm] Standard stroke [mm] *1 20 25, 50, 75, 100, 125, 150, 200, 250, 300 25 32 40 *1 Intermediate strokes not listed above are produced upon receipt of order. The minimum stroke is 25 mm. Mounting Brackets/Part No.

Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Perpendicular In-line 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Indicator light Wiring (Output) Type Special function Electrical entry M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V, 12 V Solid state auto switch 3-wire (PNP) M9PV M9P V V V v v 2-wire 12 V M9BV M9B V V V v v 3-wire (NPN) 5 V, 12 V

B 0.2 A 0.2 Bore size A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 8.

B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.

M9NV Auto-Switch D-M9NV M9NWV Auto-Switch D-M9NWV A93V D-A93V M9PV D-M9PV M9PWV D-M9PWV A96V D-A96V M9BV D-M9BV M9BWV D-M9BWV M9NA D-M9NA M9PA D-M9PA M9BA D-M9BA M9NAV Waterproof D-M9NAV M9PAV Waterproof D-M9PAV M9BAV Waterproof D-M9BAV See separate catalog for the details of Auto-switch. 2-2-3 Options Multi Counter Extension Cable *1 Supply voltage Connector Nil w/o connector C R04-J8M7.3

Indicator light Load voltage Pre-wired connector Applicable load Auto switch model Lead wire length (m) Electrical entry Solid state switch Type Reed switch Wiring (Output) Special function Perpendicular In-line 0.5 (Nil) 5 (Z) 1 (M) 3 (L) DC AC M9N M9P M9B M9NW M9PW M9BW M9NV M9PV M9BV M9NWV M9PWV M9BWV 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12

Load voltage Lead wire length (m) 0.5 (Nil) AC Wiring (output) Indicator light DC Auto switch model Applicable load Type Special function Electrical entry 3 (L) 5 (Z) Perpendicular In-line 3-wire (NPN) 5 V, 12 V M9N M9NV IC circuit 3-wire (PNP) M9P M9PV Solid state switch M9B M9BV 2-wire 12 V Relay PLC Grommet Yes 24 V 3-wire (NPN) F9NW F9NWV 5 V, 12 V IC circuit Diagnostic indication

Auto switch model Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Yes Yes Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 5 (Z) 1 (M) 3 (L) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit 5 V, 12 V Reed switch Solid state

Auto switch models Lead wire length (m) Load voltage Wiring (output) Pre-wired connector Applicable load DC AC Indicator light Type Special function Electrical entry Perpendicular In-line 0.5 (Nil) 3 (L) 5 (Z) 1 (M) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9N M9P M9B M9NW M9PW M9BW 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire IC circuit Solid state switch 5 V, 12 V 12 V Relay

AC DC Auto switch model Lead wire length (m) Pre-wired connector 0.5 (Nil) Indicator light Load voltage Wiring (Output) Special function Type Electrical entry Applicable load 3 (L) 5 (Z) Perpendicular In-line 3-wire IC circuit A96V A96 5 V Reed switch Solid state switch (NPN equivalent) Yes Yes Grommet 100 V 24 V 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV

Applicable cylinder MY1B25 MY1B32 MY1B40 75 84 105 A B MY-S25 35 50 8 11.7 5 6 9.5 5.5 M6 x 1 MY1H A B MY-S32 45 64 11 6.6 M8 x 1.25 MY1 HT Side supports consist of a set of right and left supports. MY1 W Guide to Side Support Application MY2C For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load.

Caution Standard stroke (mm) Note) Bore size (mm) 20 25 32 40 50 63 80 100 25, 50, 75, 100, 125, 150, 200 25, 50, 75, 100, 125, 150, 200, 250, 300 Note) Manufacture of intermediate strokes in 1 mm increments is possible. (Spacers are not used.)

(Except 20, 25) 55, 60, 65 and 70 mm stroke cylinders have the same overall length as a 75 mm stroke cylinder, and 80, 85, 90 and 95 mm stroke cylinders have the same length as a 100 mm stroke cylinder. Refer to the Made to Order Specifications on page 277 for the ordering procedure.

, 100 100 V 0.78 (With indicator light: 0.81) M L 20, 30, 40, 50, 75, 100 125, 150, 175, 200 110 V [115 V] 0.86 (With indicator light: 0.89) [0.94 (With indicator light: 0.97)] MVGQ 20 Apparent power (2) CV AC (VA) Intermediate stroke (mm) 200 V 1.18 (With indicator light: 1.22) MVGQ As for the intermediate strokes (by the 1 mm interval) other than the standard strokes above are manufactured

RLQ Symbol Standard Stroke MLU W MLGP Bore size (mm) Standard stroke (mm) 20, 25, 30, 40, 50, 75, 100 30, 40, 50, 75, 100 32, 40 50, 63 ML1C Manufacture of Intermediate Stroke W Retraction locking Without bypass pipe Extension locking Without bypass pipe Method Ordering Description Exclusive body Please refer to How to Order for standard part no. (page 844).

Standard Strokes (mm) Bore size Standard stroke Note1) Maximum manufacturable stroke Note 2) 1 Cylinders with rubber bumper have no bumper. 2 Only compatible with cylinders with rubber bumper, but has no bumper. 20 25, 50, 75, 100, 125, 150, 200 201 to 1500 25 32 40 50, 63 80 100 25, 50, 75, 100, 125, 150, 200, 250, 300 301 to 1500 Refer to pages 355 to 361 for cylinders with auto switches