SMC Corporation of America
Elite Part Number Search
Search Results "CXSJL32-30-M9PW"

Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic Fluid Compatibility 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Hydraulic fluid Compatibility

d 30 d (D) (C) (D) (C) H B H B Part no.

Free Mount Cylinder Double Acting, Single Rod Series CU 6, 10, 16, 20, 25, 32 How to Order CU 6 30 D 30 6 30 M9BW CDU With auto switch D Made to order Refer to page 484 for the Made to Order specifications. Built-in magnet Number of auto switches Bore size 2 pcs. 1 pc.

buffer, axial piping 6 Centralized adjuster 7 Centralized adjuster (Symmetric) 8 Buffer, Centralized adjuster 9 Buffer, Centralized adjuster (Symmetric) Nil 2 S 1 n n Port Switch mounting groove Port Switch mounting groove 8 10, 20, 30, 40, 50, 75 12 10, 20, 30, 40, 50, 75, 100 For details, refer to the next page. i Made to order 16 10, 20, 30, 40, 50, 75, 100, 125 Port Switch mounting groove

Cylinder stroke 30 40 30 mm (50, 63) Flange side Auto switch 40 mm (80) Nil Nil Without auto switch (Built-in magnet) Action D B T For applicable auto switches, refer to the table below. Auto switches are shipped together, (but not assembled).

4 4 4.5 5 4.5 5 5.5 5.5 * Values which include hysteresis are for guideline purposes only, they are not a guarantee (assuming approximately 30% dispersion) and may change substantially depending on the ambient environment.

(Assuming approximately +/-30% dispersion) There may be the case it will vary substantially depending on an ambient environment. 11-5 Auto switch mounting bracket: Part no.

Standard Strokes Symbol Rubber bumper Bore size [mm] Standard stroke [mm] 12 (10 x 2) 16 (12 x 2) 10, 20, 30, 50, 100 20 (16 x 2) 25 (20 x 2) 20, 30, 50, 100, 150 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) 25, 50, 100, 150, 200 Intermediate strokes are available as a special order. Refer to pages 10 and 11 for cylinders with auto switches.

Nil S n Size 10 15 20 30 40 Pattern Nil Standard Combination of Simple specials/ Made to Order P Auto switch Nil Without auto switch (Built-in magnet) Refer to pages 318 to 332 for details. Thread type For applicable auto switch models, refer to the table below.

9 5 27.5 16 12 32 11.5 7.5 30 14 10 37.5 14.5 10.5 35 16.5 12.5 42.5 17.5 13.5 40.5 Note) The actual mounting position should be adjusted after confirming the auto switch performance.

20, 25, 30, 35, 40, 45, 50, 75, 100 IN 840 1400 1960 63 63 OUT 936 1560 2184 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 1 The outline dimensions for 5 mm stroke will be the same as those for 10 mm stroke. 2 The outline dimensions for 10 mm stroke will be the same as those for 15 mm stroke.

Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 5, 10, 15, 20, 25, 30 20, 25, 32, 40 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 50, 63, 80, 100 10, 15, 20, 25, 30, 35, 40, 45, 50 Intermediate strokes are available as a special order.

CXT12 CXT16 CXT20 CXT25 CXT32 CXT40 0.015 0.019 0.044 0.180 0.123 0.109 3 7 12 20 30 50 60 70 125 125 140 170 0.002 0.004 0.007 0.030 0.032 0.025 350 500 900 900 1100 1900 For moving and transferring workpieces. For moving the receptacle for workpieces used in stamping or press-fitting processes. For using as a Pick & Place unit in combination with other actuators.

Auto switch precautions P.30 1) Applicable auto switches P.30 2) Precautions for use P.32 -1- 3A 3/5 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.

Compact Cylinder: Standard Type Double Acting, Single Rod Series CQS 12, 16, 20, 25 How to Order B D 30 20 CQS M9BW B D 20 30 CDQS With auto switch Made to Order Refer to page 552 for details.

(with thread) Bore size (mm) Stroke (mm) Trunnion (with pin) 4 5, 10, 15, 20 Note) Basic 6 5, 10, 15, 20, 25 Flange 10 5, 10, 15, 20, 25, 30, 35, 40 Foot 16 5, 10, 15, 20, 25, 30, 35, 40 Clevis 20 stroke of bore size 4 mm is standard type only. Trunnion Made to Order (For details, refer to pages 1373 to 1498 and 1502.) Mounting Bracket Part No.

Standard Stroke Bore size (mm) Standard stroke (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125, 150 20 to 63 Theoretical Output OUT IN 10, 15, 20, 25, 30, 35, 40, 45, 50, 60, 80, 100, 125 80, 100 Unit: N Manufacture of Intermediate Stroke Bore size (mm) Operating direction Operating pressure (MPa) 0.3 0.5 0.7 Dealing with the stroke by the 1 mm interval by using an exclusive

Smooth Cylinder Series CQSY 12, 16, 20, 25 How to Order B 20 D 30 C CQSY M9BW B D 20 30 C CDQSY With auto switch Number of auto switches Nil S n With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.