Output Output 3 B Output 1 Output 2 A B C Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B A Dimensions D3 Metric size: Light gray Inch size: Orange D2 L5 M2 IN Blue L3 L2 L4 OUT IN D1 M1 Applicable tubing dia. d M1 L1 Metric size: Light gray Inch size: Orange
COMPACT COMPRESSOR. COMPACT COMPRESSOR. 3510.00000 lb. Q38.
Weight (g) d L4 Model L3 D1 T H D2 D3 L1 L2 Max. Min.
D1 D2 D2 L6 L6 L3 L4 AS H H ASP (Width across flats) (Width across flats) ASN D3 D3 AQ A1 A1 ASV L5 L5 A2 A2 AK ASS T T ASR ASF Model T H D1 D2 D3 L1 L2 L6 A2 M L5 A1 Weight (g) Note 5) MAX.
Switch operating position (ON) Hysteresis Switch reset position (OFF) Unit: mm Auto switch model Air gripper D-Y7 W N B D-Y59A B D-Y69A B D-Y7 WV N B D-Y7BA 0.8 0.6 0.7 0.5 MHL2-10Dl Note)Use a watchmakers screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch set screw. Use a tightening torque of 0.05 to 0.1 Nm.
When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off.
JXC-W2 The conversion cable can be used for connecting this controller to the optional teaching box [LEC-T1] offered with the LEC series. or USB cable PC (A-mini B type) (0.8 m) Conversion cable p. 7 1 A conversion cable is also required for connecting the controller to the LEC-W2.
Description Material Note Body A 1 PBT Handle 2 PBT Body B 3 Stainless steel 303 Needle 4 Stainless steel 303 Needle guide 5 Stainless steel 303 Lock nut 6 Stainless steel 303 U seal 7 HNBR Spacer 8 Cassette 9 Seal 10 NBR O-ring 11 NBR Dimensions Applicable tubing O.D. d Metric Size Inch Size Model d Weight (g) D1 D2 L1 L2 L3 (1) Model d Weight (g) D1 D2 L1 L2 L3 (1) Max. Min. M1 Max.
L3 M D2 L1 Connecting thread T L2 H D1 D2 L1 L2 L3 L4 (1) A (2) Max.
Orange Calculation of Connected Plug and Socket Dimension Overall length of connected plug and socket B = Plug (L1 L2) + Socket (L2) + 0.5 Plug Socket Example) Overall length of KK3P-01MS (plug) and KK3S-01MS (socket) when they are connected.
Reference dimensions of 10-32 UNF and NPT threads after installation. 15-9-79 6 Dimensions Universal type L6 D4 Applicable tubing O.D. d H D1 (Hexagon width across flats) M1 L3 A L4 L5 D3 L1 D2 T L2 Metric Size Inch Size A Model A d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 M1 d T H D1 D2 D3 D4 L1 L2 L3 L4 L5 L6 Model M1 AS131F-M5-23D AS131F-U10/32-01D 1/8" 8.4 3.2 8.4 19.8 19.8 12.7 17.5 28.7
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
Description Material Note Body A 1 PBT Handle 2 PBT Body B 3 Stainless steel 303 Needle 4 Stainless steel 303 Needle guide 5 Stainless steel 303 Lock nut 6 Stainless steel 303 U seal 7 HNBR Spacer 8 Cassette 9 Seal 10 NBR O-ring 11 NBR Dimensions Applicable tubing O.D. d Metric Size Inch Size Model d Weight (g) D1 D2 L1 L2 L3 (1) Model d Weight (g) D1 D2 L1 L2 L3 (1) Max. Min. M1 Max.
L4 Weight (g) A L3 L1 L2 D1 D2 D3 Part No.
type: Stainless steel 615 Series AS20-T Dimensions L4 D3 H (Hexagon width across flats) T2 L3 A L2 D1 D2 T1 L1 Dimensions A AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 8 9 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 Weight (g) 13 9 4.5 10 31 10.3 0.7 27.4 AS220-N01-ST NPT 1/8 12.7 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 12 14.3 R 1/8 33 14.6 7 18 34.7 13.2 1.5 31.6 AS220
10 L2 A 8 D1 KS KX 6 D2 18.5 10 10 21.8 12.8 10 H Connection threads 8 15.2 20.5 26 18 25.3 12 KM (R) (R) 2 x Applicable tubing 10 18.5 23 41 29 28.4 17 KF 17 L1 20.9 12 24 58 46 30.4 22 M D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.
Applicable Applicable Port B min. port size Weight (g) size d D1 Part No. D2 L1 L2 L3 P Q1 Q2 A MB MA tube O.D.
0.2 0.1 0.2 C and b values are for controlled flow with the needle fully open and free flow with the needle fully closed.
Orange Calculation of Connected Plug and Socket Dimension Overall length of connected plug and socket B = Plug (L1 L2) + Socket (L2) + 0.5 Plug Socket Example) Overall length of KK3P-01MS (plug) and KK3S-01MS (socket) when they are connected.