When using a stopper cylinder for intermediate stopping of a load connected directly to a cylinder, etc. The operating ranges shown in this catalog apply only for stopping of a pallet on a conveyor. When using a stopper cylinder to stop a load connected directly to a cylinder, etc., the cylinder thrust will become a lateral load.
A Unused A Unused A Unused A Unused A Unused A B A B A B A B A B A A A B A B A B A A A A 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 7 8 9 10 11 12 13 14 15 0 0 1 2 3 4 5 Type SC OMRON Corporation SYSBUS Wire System Type SD SHARP Corporation Satellite I/O Link System ADDRESS NO. STATION NO.
Operation stop Related Equipment Combination Symbol: D1 Combination Symbol: D4 Application: The supply pressure is controlled by the external valve and a vacuum release is effected by the solenoid valve. Application: The supply pressure is controlled by the external valve and a vacuum release is effected by external air signals.
With end lock Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Piston seal A A A CX2 R H R H CXW 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
A B A B A B A B MY-S16 MY-S25 MY-S32 MY-S40 63.6 091 130 182 Note) A set of side supports consists of a left support and a right support.
Stabilize the source pressure by providing a tank and a vacuum regulator. Provide a vacuum switch valve to individual lines.
Select between two values 2-A or 1-A using the + and keys. The value 2-A indicates a double acting actuator and 1-A a single acting actuator. To conclude press the ?
From a point indicating 500 mm/s on the axis of abscissas, extend a line upward and find a point where it intersects with a line for the 63 mm bore size. Extend a line from the intersection to the left and find a load mass 80 kg.
a a1 B c d d1 e e LECSS2-T5LECSS2-T7 LECSS2-T8 6 6 1560.5 6 M5 b LECSS2-T9 c 12 12 1560.5 6 420.3 M5 d a 4.9 /LECS / 1./ YES [ ]NO [ ] 2.
CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution : WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning : DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Caution Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Caution: Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1.
Set of long clamping screws ZH2-TB203-A 3 M4 x 70 2 pcs. ZH13DA ZH15DA ZH2-TB204-A 4 M4 x 90 2 pcs. ZH2-TB206-A 6 M4 x 130 2 pcs. Hexagon nut (M4) 2 pcs. ZH2-TB208-A 8 M4 x 170 2 pcs. (ZH2-TB201-A)3 1 M4 x 30 2 pcs. Flat washer (for M4) 2 pcs. ZH2-TB302-A 2 M4 x 55 2 pcs. ZH2-TB303-A 3 M4 x 80 2 pcs. ZH18DA ZH20DA ZH2-TB304-A 4 M4 x 100 2 pcs. ZH2-TB306-A 6 M4 x 145 2 pcs.
Male elbow: KRL Inch e l b a c i l p p A . D .
When tightening the auto switch mounting screw, use a watchmakers screw driver with a handle diameter of about 5 to 6mm. Furthermore, use a tightening torque of 0.05 to 0.1 Nm. As a rule, it should be turned about 90 from the point at which tightening can be felt. Use a tightening torque of 1 to 1.2 Nm for the hexagon socket head set screws (M4 x 0.7). 1.
Note No. 6 and 8 only function when a surface electric potential sensor is used. 2. 3. When a surface electric potential sensor is used, remove the cover cap plugging a modular jack for indicating [signal] on ionizer body, and insert a modular plug of sensor cable IZS30-CS.
As a guide, tighten it by hand, then turn it two or three turns with a wrench. Check the dimensions of each product for the hexagon width across flats.
Can be used for a wide range of pressures from low vacuum up to a pressure of 1.0 MPa. The use of a special profile ensures sealing and reduces resistance when the tube is inserted. Guide Collet Can be used in copper-free application. Body O-ring Flame resistance (Equivalent to UL-94 standard, material V-0) Stud Tube Effective when piping in a confined space.
D2 M1 L1 L2 T M5 type H (width across flats) Applicable tubing O.D. d A A4 D1 L3 D2 M1 L1 T L2 Model Weight (g) Note 2) Tubing O.D. d T H D1 D2 L1 L2 L3 M1 L4 Max.
9 i *1 *1 C95K32 A A-A A !2 !1 @4 Component Parts Description Aluminum die-casted Aluminum die-casted Aluminum alloy Stainless steel Aluminum alloy Rolled steel Rolled steel Oil impregnated sintered alloy Steel Steel for spring Carbon Steel Steel Steel Material No. !4 !5 !6 !7 !8 !