1000 Ambient temperature 35C 500 500 0 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] Circulating fluid temperature [C] 0 10 20 30 40 50 60 70 Heating Capacity HECR002-A Circulating fluid: Tap water Circulating fluid: Ethylene glycol 20% 1000 900 800 700 600 500 400 300 200 100 0 1000 900 800 700 600 500 400 300 200 100 0 Heating capacity [W] Heating capacity [W] Ambient temperature
(V), D-A93(V), D-A96(V) Auto Switch Specifications D-A96 D-A90 D-A90V D-A93 D-A93V In-line D-A96V Auto switch part no.
D-F5LF (2 color indicator) D-A53 D-A54 D-A56 D-A64 D-A67 D-A59W (2 color indicator) Single rod Series MNB 40 50 63 80 100 25 to 500 Cylinder with Lock Series MNB Tie-rod mounting type 25 to 600 Double acting Double rod Series MNBW 25 to 700 Feature 2 Cylinder with Lock Double Acting: Single Rod Series MNB 32, 40, 50, 63, 80, 100 How to Order MNB L 50 100 D Standard type With auto switch
Proper Auto Switch Mounting Position (Detection at stroke end) C D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A B Series MY2C Series MY2H Series MY2HT (mm) D-M9, D-M9V (mm) D-M9, D-M9V (mm) D-M9, D-M9V A A A B B B Bore size 16 25 40 Operating range Bore size
MXQ MXF MXW MXP MG MGP MGQ MGG MGC MGF CY1 MY1 3.2-9 Series MLGC Proper Mounting Positions of Auto Switch (Stroke End) D-C7/C8 D-H7 D-B5/B6 D-G5/K5 D-B7/B8 D-G7/K7 Setting Positons of Auto Switch Mounting Height of Auto Switch (mm) (mm) Model D-B7/B8 D-B73C D-B80C D-G7/K7 D-K79C D-H7C D-G5/K5 D-G5lW D-K59W D-G5NTL D-B5/B6 D-B59W D-G5BAL D-G59F D-B5/B6 D-G5lW D-K59W D-G5BAL D-G59F D-B7/B8
C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
Maximum load current 500 mA AC/DC (Resistance load) Contact output signal 1, 2, 3 Minimum load current 5 VDC 10 mA 24 VDC Output voltage 24 VDC 10% 500 mA MAX1 (No inductive load) 1 When using the power supply of this product, make sure that the total load current is 500 mA or less. Contact Input/Output Pin Nos. Pin no.
121.5 110.5 95.5 80.5 Operating range Note) Operating range Note) 8 8 8 5.5 5 5 5 5.5 11.5 11.5 12 12 12 Operating range Note) Perpendicular electrical entry is not available for 50 and 63. ( ) D-Y69A, D-Y69B, D-Y7PV D-Y7NWV, D-Y7PWV, D-Y7BWV MY1CW25/32/40/50/63 B A Reed Switch Solid State Switch D-Z73, D-Z76, D-Z80 (mm) D-Y7BAL (mm) D-Y7NW(V), D-Y7PW(V), D-Y7BW(V) D-Y59 , D-Y69 , D-Y7P(
side D D D D D D SS5V1-16S3AD-06B-C61 set (manifold part no.)
Name plate FGF ORIENTATION W BACK WASH OUT E FGH K J N FQ1 FN EB ES Standard Models (mm) Internal volume (L) Number of arranged elements Weight (kg) Element length (L) Model N (Port size) G W A B C D E F H J K P 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 250 20 70 15 330 216.3 230 490 660 965 80 120 25 (1B) 40 (1 1/2B) 50 (2B) 20 (3/4B) 20 (3/4B) 500 4 500 20 80 24 330 216.3 230
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 50mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: P (Air Pressure Lock-up)
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 125mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 700mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 100mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 150mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 25mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 300mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]
Magnet: None, Mounting: G (Rear Flange), Style: Aluminum Tube, Bore Size: 100mm, Thread: Rc, Stroke: 350mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: E [Spring Lock (Lock Exhaust)]