Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 5, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket: Compact

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: Single Acting, Spring Return, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.07~1, Cushion: -, Specification: Built-in magnet

Magnet: D (Built-in), Mounting: LC (Compact Foot), Type: Standard, Bore Size: 12mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: W (Double Knuckle Joint), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:

CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v

Nil (Example) M9NV 3 m . L M9NVL Refer to page 12-13-1 for further information on auto switches. Auto switches marked with a "" are made upon receipt of order. Unit list Gripper unit Switch mounting unit Model Unit part no. Model Unit part no.