Magnet: D (Built-in), Mounting: F (Front Flange), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: Built-in, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: Rc, Stroke: 1200mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch

Magnet: Built-in, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: Rc, Stroke: 1200mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 500mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9BV--Solid State , Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: NPT, Stroke: 300mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: 2 pcs.

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Magnet: D (Built-in), Mounting: B (Standard), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 125mm, Thread: TN (NPT), Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Pre-wired Connector: L (3m Lead Wire), Number: 2 pcs. (Or None in the

AC Lead wire length (m) Load voltage DC Auto switch model Special function Electrical entry Indicator light Wiring (Output) Pre-wired connector Applicable load Type In-line Perpendicular 0.5 (Nil) 1 (M) 3 (L) 5 (Z) M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV M9N M9P M9B M9NW M9PW M9BW M9NA M9PA M9BA 5 V, 12 V 3-wire (NPN) 3-wire (PNP) IC circuit Solid state switch 12 V 2-wire 3-wire

Model: MSQ, Precision: B (Basic), Size: 100, Suffix: R (Shock Absorbers), Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal

Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal

Precision: A (High Precision Type), Size: 50mm, Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal

Precision: High Precision Type, Size: 50mm, Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Sensor Type: Non-Contact, Output Format: PNP Format, Wiring Method: 3-Wire, Type: Main Body, Wiring type: 3-wire type, Output Type: NPN type, Electrical entry direction: In-line, Lead wire length(m): 0.5, Connector Type: None

Model: MSQ, Precision: High Precision Type, Size: 50, Suffix: Adjuster Bolt, Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Thread Type: -

Model: MSQ, Precision: Basic, Size: 10, Suffix: Shock Absorbers, Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Thread Type: -

Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Valves: Not Provided, Allowable Kinetic Energy(J): 0.294, Format: With internal shock absorber, Size: 50, Switch: M9NA

Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 1 to Less than 50, Valves: Not Provided, Allowable Kinetic Energy(J): 1.600, Format: With internal shock absorber, Size: 100, Switch: M9NA

Magnet: Built-in, Mounting: Front Flange, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 200mm, Thread: Rc, Stroke: 100mm, Option: Cushion at Both Ends, Cylinder Switch Type: A53--Reed, DC Volt >5<24, LED, 0.5M, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the

The CLS series cylinder with lock is ideal for applications requiring intermediate and emergency stop and drop prevention. The compact lock unit is lightweight and saves space. A switch is optional on the brake cylinder so the operating state of the lock unit (brake piston) can be detected using the switch signal. By separating the lock mechanism and the brake cylinder, SMC has minimized