2 38 4 12 P O R T T H R E A D T NPTF* Remove (N) when ordering F G(PF)* Remove (N) when ordering N NPT P R E S S U R E A D J U S T M E N T 1 Handle 2 Air Pilot (VBA 2000, 4000 only) P O R T I N G 02 1/4 (1110) 03 3/8 (2100, 2200) 04 1/2 (4100, 4200) P R E S S U R E R A N G E 0 1MPa Max (2000, 4000 Series) 1 2MPa Max (1000 Series) D I M E N S I O N S S E E N E X T P A G E Courtesy of Steven
keeper plate mounting screw J P H A B C D d K L L1 E Part no.
Side support L type Block type MY1 Series Variations Bore size (mm) Series Page 16 20 25 32 40 50 63 80 100 10 P.1188 MY1B P.1233 MY1B P.1257 MY1M P.1277 MY1C MY1H P.1201 MY1H End lock MY1H P.1297 MY1H End lock P.1319 MY1HT MY1W P.1339 1184 MY1B Series Prior to Use Maximum Allowable Moment/Maximum Load Mass Caution on Design Maximum allowable moment (Nm) Maximum load mass (kg) m1 Bore size
port R P A, B port P port -+ -+ A B R P -+ -+ A B B R port R P For detailed specifications about SYJ3000, refer to page 14.
Discharge Volume 1500 200 1500 VXF(A)28B VXF(A)23A VXF(A)27B 150 Discharge volume (L) Discharge volume (L) Discharge volume (L) 1000 1000 VXF(A)25A, B 100 VXF(A)26< 500 500 VXF(A)22A 50 VXF(A)24A VXF(A)21A 0 0 0 0 500 1000 1500 Piping length to the pilot valve (mm) 0 500 1000 1500 Piping length to the pilot valve (mm) 0 500 1500 1000 Piping length to the pilot valve (mm) 8 Series VXF2/VXFA2
: Change this to a smooth cylinder (CS2). 1 1 DCQSY CQ2Y CM2Y CG1Y CA2Y CQSX CQ2X CM2X CJ2X CUX CS2Y -X P. 1168 P. 1176 P. 1189 P. 1203 P. 1214 P. 1228 P. 1261 P. 1268 P. 1280 P. 1246 P. 1256 1165 Series CY/CX Smooth Cylinder/Low Speed Cylinder Added compact type foot brackets. Compact foot bracket has the same width as the cylinder. Overall width reduced by up to 43% (for 12).
MY1B P . 8-11-16 MY1M P . 8-11-40 MY1C P . 8-11-56 MY1H P . 8-11-72 MY1CW P . 8-12-14 MY1MW P . 8-12-14 Stroke adjusting unit For applicable symbol, refer to the table below. Note) For MY1H, the parts are packed together when shipped. Stroke Note) Indicates the stroke prior to mounting the stroke adjusting unit.
4 ZSE20C-L(-M): 1 ZSE20C-L-P: 4 ZSE20CF-L(-M): 1 Unit (Selection of display unit) 0x03E8 (1000) 0 R/W Y U8 ZSE20CF-L-P: 4 ISE20CH-L(-M): 0 ISE20CH-L-P: 4 NorP (Selection of PNP/NPN) Setting of switch output specification 0: NPN 1: PNP 0x03E9 (1001) 0 R/W Y U8 0x01 (1) Setting of display color 0: red (Constantly red) 1: Grn (Constantly green) 2: 1SoG CoL (Selection of display color) (OUT1
Unit switching Real-time switch output ( ) ZSE ISE For Air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON PSE YES CFM x 102, CFM x 101 ft3 x 101 OFF P-1 P-2 High flow rate Z I SE3 CFM = ft3/min P Window comparator mode H: Hysteresis High Flow Rate Type (For Air) PS H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON Z I SE1 2 NO OFF P-1 P-
Standard Stroke Minimum Strokes for Auto Switch Mounting Bore size (mm) Standard stroke (mm) Max. stroke Refer to p.1.11-32 on "Minimum Strokes for Auto Switch Mounting". 32 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 Theoretical Force 50 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1000 25, 50, 80,
LJ1H202NC 14 56 to 740 to 930 to 600 to 500 to 1000 LJ1H303PD to 1000 to 1000 to 700 to 500 18 60 to 1000 126 114 108 LJ1H303ND 20 62 to 1000 to 1000 to 700 to 500 to 1000 LJ1H102PH-K 24 66 to 400 104 110 LJ1H102NH-K 28 70 to 400 LJ1H202PA-K 34 76 to 500 106 112 LJ1H202NA-K 38 80 to 500 LJ1H102PB-K 26 68 to 600 145 104 110 LJ1H102NB-K 30 72 to 600 LJ1H202PF-K 32 74 to 250 106 112 LJ1H202NF-K
For 4 Axes Step Axis Movement mode Speed Position Acceleration Deceleration Positioning/ Pushing Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 100 200.00 1000 1000 0 6.0 12.0 0.5 Axis 2 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 0 Axis 3 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 4 ABS 50 100.00 1000 1000 0 6.0 12.0 0.5 Axis 1 INC 500 250.00 1000 1000 1 0 0 20.0
size determination F3 D 1.6 x P WB Inclined operation W + WB WV P PV W + WB WV P PV Determination of allowable load mass & pressure (Refer to page 1466 for vertical operation.)
P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.
From 0.4 MPa Graph (6) m From 0.5MPa Graph (7) F 6-12-27 Series C95N Selection Graph Graph (5) Graph (2) 0.3 MPa P < 0.4 MPa 0.3 MPa P < 0.4 MPa 1000 1000 500 400 300 500 400 300 100 80 200 200 63 100 80 100 100 50 40 100 100 Load weight: m (kg) Load weight: m (kg) 63 50 40 30 50 40 30 32 50 40 20 20 32 10 10 5 4 3 5 4 3 2 2 1 100 200 300 400 500 1000 1 100 300 400 500 1000 200 Maximum
+ -+ R P R P P port 1/4 R port 1/4 P port 1/8 R port 1/8 Note) If there are more than 6 stations for type 20, or more than 9 stations for 21 type, supply air to both sides of P port and exhaust air from both sides of R port.
ARBF2000-00-P JIS Symbol Inlet pressure 0.7 MPa Outlet pressure (MPa) P port regulation A port regulation B port regulation Flow rate (l/min (ANR)) ARBF3050-00-P ARBF4050-00-P ARBF5050-00-P 0.6 Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa Inlet pressure 0.7 MPa 0.5 Outlet pressure (MPa) Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.3 0.2 0.1 0 1000 2000 3000 4000 Flow rate (l/min (ANR
Micro Mist Separator AFD30-A P.28 AFD40-A AFD40-06-A AR AR20-A AR25-A P.44 AR30-A Regulator AR40-A AR40-06-A Front matter 2 Series AC Modular F.R.L.
PA06 1 262144 (Position control mode) 2400 1600 800 3000 2000 1000 2700 4200 Electronic gear denominator *3.
Note 4) The stroke range with rod boot is up to 1000 mm. Please consult with SMC when exceeding 1000 mm strokes.