Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 175mm, Option: N [w/o Rod Boot, w/o Cushion (Not Valid for Air-hydro), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 200mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 250mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 500mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 600mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Magnet: Built-in, Mounting: Double Clevis, Style: Aluminum Tube, Bore Size: 80mm, Thread: Rc, Stroke: 900mm, Option: w/o Rod Boot, Cushion: Both Sides (Air-hydro has No Cushion), Lock Operation: Spring/Air Pressure Lock, Auto Switch: -, Lead Wire or Prewied Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type: Rc
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): -, Specification: -, Port thread type:
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.08 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification
RHC RZQ D-X Individual -X 961 Series REAS Auto Switch Proper Mounting Position (Detection at Stroke End) B A (mm) A dimension B dimension Auto switch model D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/F7WV D-F7BA D-F79F D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7W/J79W D-J79C D-F7V/FWV D-F7BA D-F79F D-F7NTL D-A73/A80 D-F7NTL D-A73/A80 Bore size (mm) 10 35 35.5 45 44.5 40.5
15 Auto switch model Bore size (mm) D-A9 A dimension D-M9 B dimension C dimension D dimension D-A9 D-M9 D-A9 D-M9 D-A9 D-M9 21.5 76.5 72.5 56.5 60.5 17.5 15 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 A dimension D-Y5 D-Y6 D-Y7 B dimension C dimension D dimension Auto switch model D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Y5 D-Y6 D-Y7 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8
Note 2) The figure shows an extended piston rod. 10-9-10 10 Heavy Duty Stopper Cylinder Series RSH/RS1H Proper Auto Switch Mounting Position Auto switch B A RE A B REC CX CY Proper Auto Switch Mounting Position D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W Auto switch models MQQ M D-Y69 D-Y7PV D-Y7WV D-Y7BAL Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: