SMC Corporation of America
Elite Part Number Search
Search Results "CDJ2B10-30Z-A93V-A"

Series CJ2 is auto switch capable Standard double acting single rod, Bore sizes: 6, 10, 16 *, Strokes from 15mm through 200mm depending upon bore size, Mounts: basic, foot, front flange, double clevis, Variety of switches and a variety of lead wire lengths ROUND BODY CYLINDER. Cylinder, Air. 0.09300 lb. 359.

All three series, VQ, SX and SY, are c o m p a c t , l i g h t w e i g h t a n d a e s t h e t i c i n a p p e a r a n c e .

, d e t e r i o r a t i o n o f a c c u r a c y, a n d breakage of parts.)

Operating principle A + A' A' A Piston seal A' A' R H R H When the piston is retracting, air is exhausted through both A and A' until piston seal H passes air passage A. After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved.

Applicable models: D-A93, D-A93V, D-Z73 1) Even if connections are reversed on a 2-wire type switch, the switch will not be damaged because it is protected by a protection circuit, but it will remain in a normally on state. However, it is still necessary to avoid reversed connections since the switch will be damaged if a load short circuits in this condition.

D-F9 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 Switch Hysteresis D-F9W 6 15 19 41 46 43.5 Proper auto switch mounting positions (Series CEP1 ) (mm) Bore size (mm) 12 Auto switch model Symbol 20 A B A B A B A B A B A B A B 75.2 82 Switch operating position (ON) D-A90, A93, A96 7.9 12 75.2 82 D-A90V, A93V, A96V 7.9 12 Hysteresis Reed switch: 2mm or less Solid state switch: 1mm or less 79.2 86

Auto switch model Bore size (mm) 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-A9(V) BMA3-020 (A set of a, b, c, d) BMA3-025 (A set of a, b, c, d) BMA3-032 (A set of a, b, c, d) BMA3-040 (A set of a, b, c, d) BMA3-050 (A set of a, b, c, d) BMA3-063 (A set of a, b, c, d) D-M9A(V) Note 2) BMA3-020S (A set of b, c, d, e) BMA3-025S (A set of b, c, d, e) BMA3-032S (A set of b, c, d, e) BMA3-040S

When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.

A + A' A' w After piston seal H has passed air passage A, air is exhausted only through A'. The section marked with slanted lines becomes a cushion chamber, and an air cushion effect is achieved. A A' A' e When air is supplied for the piston extension, the check valve opens and the piston extends with no delay.

Use 0.3 to 0.7 times the thrust (differs depending on the operating speed) as a guide for actual use. g: Gravitational acceleration Dynamic moment Mounting orientation Dynamic load FE Horizontal Ceiling Wall Vertical Z M 1.4 100 x a x mn x g 1 3 a a ME x FE x Z Dynamic moment ME Dynamic moment ME does not occur. 1 3 mn x g ME M3 ME x FE x Y mn x g ME FE FE Note) Regardless of the mounting

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 100mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 15mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 30mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 75mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 150mm, Head Cover: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Air Cushion, Series: J2

Magnet: Built-in, Mounting: Basic, Bore: 10mm, Stroke: 60mm, Head Cover: Axial, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting: Rail Mounting, Cushion: Rubber Bumper, Series: J2

The number of the switches: N/A, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: 90° to axis, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet

The number of the switches: N/A, Type of Auto Switch Mounting: Rail mounting, Head Cover Port Position: Axial direction, Pivot Bracket: Without bracket, Rod End Bracket: Without bracket, Type of Mount Support: Basic type, Custom-made Specifications: None, Lock unit magnet: Built-in magnet