Lead wire length (m) Auto switch model Load voltage Indicator light Wiring (Output) Special function Type Electrical entry Pre-wire connector Rail mounting Band mounting Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit C76 A76H Reed switch Solid state switch Grommet C73 C73C H7A1 H7A2 H7B H7C H7NW H7PW H7BW H7NF A72 A73
Auto Switch Mounting Position Auto Switch Mounting Height D-A7H/J79W D-A80H/F7BAL D-F7/F7F D-F79/F7NTL D-F7W D-A72/A7H/A80H D-A73C/A80C D-F7/F7V/F7W D-F7WV/F7BAL D-J7 D-A73C D-A80C D-F7WV D-F7V D-J79C D-A7/A8 D-A79W D-A73 D-A80 D-A79W D-F7F D-F7NTL Bore size (mm) Bore size (mm) A B A B A B A B A B Hs Hs Hs Hs Hs Hs 20 25 32 40 50 63 80 100 20 25 32 40 50 63 80 100 40.5 39.5 40 39 37.5 36.5
Order with the part number “CDQ2B50-30DCZ-BQ,” which includes the current cylinder as well as 2 D-A73 auto switch mounting brackets. If you have already purchased a CDQ2B50-30DCZ, please order the 2 D-A73 mounting brackets using the part number “BQ5-032.”
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PLATFORM, ACTUATOR, CXT PLATFORM CYLINDER, LM, 32MM CXT SLIDE BEARING, 18.29836 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, PLATFORM, ACTUATOR, CXT PLATFORM CYLINDER, MM, 40MM CXT SLIDE BEARING, 27.77824 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, GE, 15MM CY1H/CY1L DBL-ACT A/S, 4.20977 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)15CY1L15H7.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, HE, 20MM CY1H/CY1L DBL-ACT A/S, 7.30673 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)20CY1L20H11.00.65
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, SLIDER, ACTUATOR, 15MM CY2S DBL-ACT AUTO-SW, 3.30693 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, ME, 40MM CY1H/CY1L DBL-ACT A/S, 24.69177 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)40CY1L40H47.00.65
d D ( 4 A 2 2 2 = (4) F=[N] F=[N] = A=[mm] A=[mm] D=[mm] d=[mm] P=[MPa] 5.6 () 5.7 () 5.5 23 6. 6. 6. 6. ,, , ,, 6-1. 6.1 (m) DC AC 0.5 3 5 (L) (Z) (N) 3 (NPN) F7NV F79 3 (PNP) 5V,12V F7PV F7P IC F7BV J79 2 12V J79C 24V 3 (NPN) F7NWV F79W PLC 3 (PNP) 5V,12V F79W IC (2 ) F7BWV J79W (2 ) 2 12V F7BAV F7BA (2 ) 4 (NPN) 5V,12V F79F IC 3 (NPN ) 5V A76H IC 200V A72 A72H 100V A73
Part No. of Lead Wires with Connectors (Applicable only for connector type) Note 1) Lead wire length Z: 5 m Applicable auto switches Reed auto switch: D-B53/B54, D-C73(C)/C80C, D-A73(C)(H)/A80C, D-A53/A54, D-Z73, D-90/97/90A/93A Solid state auto switch: Manufactured upon receipt of order as standard.
IC circuit A76H A96V A96 5 V Grommet A72 A73 A72H A73H 200 V Reed switch Solid state switch 100 V 12 V A93V A93 Relay, PLC 2-wire 24 V A73C 12 V Connector Diagnosis (2-color indication) Grommet A79W 3-wire (NPN) F79 M9NV M9N F7NV 5 V 12 V IC circuit Grommet 3-wire (PNP) F7P M9PV M9P F7PV J79 M9BV M9B F7BV J79C 12 V 2-wire Connector 3-wire (NPN) F79W F7NWV F9NWV F9NW Relay, PLC IC circuit
A76H 5V A96 A96V IC V V A72H A73H A72 A73 200V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V Grommet Yes Reed switch Solid state switch V 100V 12V A93 A90 A93V A90V Relay PLC 2 wire A80H A80 A73C A80C A79W F7NV IC No Yes No Yes 5V,12V 100V 24V 24V 12V V V V V Connector IC 5V,12V Diagnostic indication (2 color) Grommet F79 IC 5V,12V 3 wire (NPN) 3 wire
In-line 3 wire (NPN) C76 A76H 5V IC Yes Reed switch Solid state switch A72 A73 A80 A73C A80C A79W F7NV F7PV F7BV J79C F7NWV A72H A73H A80H 200V Ex.
IC circuit A76H A96V A96 5 V Grommet A72 A73 A72H A73H 200 V Reed switch Solid state switch 100 V 12 V A93 A93V Relay, PLC 2-wire 24 V A73C 12 V Connector Diagnosis (2-color indication) Grommet A79W 3-wire (NPN) F79 M9N M9NV F7NV 5 V 12 V IC circuit Grommet 3-wire (PNP) F7P M9P M9PV F7PV J79 M9B M9BV F7BV J79C 12 V 2-wire Connector 3-wire (NPN) F79W F9NW F9NWV F7NWV Relay, PLC IC circuit
Reinforcing bracket Mounted in case of 301mm or longer strokes Front mounting flange Width across flats HT B HS C D View C-C' HU D' C' A R Y + Stroke View D-D' Auto switch mounting position Auto switch mounting height (mm) (mm) D-A72, A7H, A80H D-A73C, A80C D-F7, F7V, F7W D-F7WV, F7BAL D-J7 D-A7H, J79W D-A80H, F7BAL D-F7, F7F D-J79, F7NTL D-F7W D-A7, A8 D-F7V D-J79C D-A79W D-A73C D-A80C D-F7WV D-A73
Pre-wire Type Special function Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC connector Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A76H A96V A96 Grommet Reed switch Solid state switch A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 200 V A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72 A73
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Applicable bore size D-A72 D-A73 Grommet (Perpendicular) Without indicator light D-A80 D-A79W Diagnosis (2-color indicator) Reed switch D-A73C Connector (Perpendicular) D-A80C Without indicator light D-A72H Grommet (In-line) D-A73H, A76H D-A80H Without indicator light BQ5-032 32 to 63 D-F7NV, F7PV, F7BV D-F7NWV, F7BWV Diagnosis (2-color indicator) Grommet (Perpendicular) D-F7BAVL Water