ADDRESS 4632 4632 4632 1 1 1 9 9 9 PW LRUN ON POWER ALARM COMM Name of terminal block, LED Note Cable wiring 2 2 2 1 ON 8 8 8 O N 3 3 3 7 7 7 4632 4 4 4 6 6 6 SD RD LERR. 5 5 5 POWER SEND x 10 x 1 1 2 3 4 5 6 7 8 OFF DG 24 V 0 V D G D G 0 V 24 V 24 V 0 V A B SG FG 0 V 24 V 24 V 0 V +24V 24G DA DB FG Description LED ON for SI unit power supply input Description LED Description LED POWER COMM
X B 5 S T D. R O D T H R E A D S T D.
Operating Range Bore size Auto switch model Bore size (mm) Auto switch model 5 6 8 5 6 8 D-A9 /A9 V D-M9 /M9 V D-M9 W/M9 WV D-M9 AL/M9 AVL 11.5 12.5 12 D-A9 /A9 V D-M9 /M9 V D-M9 W/M9 WV D-M9 AL/M9 AVL BS5-125 BS5-125 BS5-160 6.5 6.5 6 * Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)
(In this case, be sure to connect a reverse voltage suppression diode.) + +V D OUT OV X Relay Other Warning 1.
H2 H1 L2 L1 Nozzle with male thread/KN (mm) Model Nozzle size D Connection size L1 A Width across flats H1 Connection thread 1 1.5 1 1.5 2 2.5 6 4 6 4 6 6 8 8 R 1/8 R 1/8 R 1/4 R 1/4 R 1/4 R 1/4 R 1/4 R 3/8 R 3/8 R 1/2 R 1/2 R 3/4 R 3/4 R 1 10 10 14 14 14 14 14 17 17 22 22 27 27 36 21.4 21 31.4 31 30.5 30.1 27.1 31.8 30.1 41.8 40.1 49.6 47.8 62.8 17.4 17 25.4 25 24.5 24.1 21.1
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
The length is 24 when any of the following auto switches are used: D-90/90A/S99(V)/T99(V)/S9P(V) The length is 30 when any of the following auto switches are used: D-97/93A 2. The angle is 60 when any of the following auto switches are used: D-90/90A/97/93A The angle is 69 when any of the following auto switches are used: D-S99(V)/T99(V)/S9P(V) 3.
Stations 3 2 1 D D D D How to Order Valve 10-SV 1 1 0 0 F 5 Note) q w r e t y u i Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors q Series r Back pressure check valve Note) Available with manifold block for station additions.
MB = ~Hs Auto switch = ~ Hs Auto switch MB1 CA2 CS1 Proper Auto Switch Mounting Position Auto Switch Mounting Height D-G5W D-K59W D-G59F D-G5 D-K5 D-G5NTL D-G5BAL D-H7 D-H7C D-H7W D-H7BAL D-H7NF C76 D-G5NTL D-G59F D-H7C D-G5BAL D-C7/C8 D-H7 D-H7W D-H7F D-H7BAL D-B5/B6 D-B59W D-G5/K5 D-G5W D-K59W Auto switch model D-C7/C8 D-C73C D-C80C D-C73C D-C80C D-B5/B6 D-B59W C85 Bore size (mm) C95 HS
Note 2) Without valve mechanism Option Combinations Combinable Impossible Depends on the model Applicable Filter Regulator Option Auto drain Symbol AW4000 Description AW1000 D D C 1 2 6 8 C J N R W AW2000 AW3000 D D C 1 2 6 8 C J N R W Auto drain pressure differential style Auto drain float style (N.O.)
1 to 5 V, 0 to 5 V 0 to 20 mA, 4 to 20 mA EX600-AMB Max. rated input signal 22 mA Note 2) 15 V 250 100 k Input impedance 0.05% F .S.
D-X Auto switch 20Data Proper Auto Switch Mounting Position Auto Switch Mounting Height D-A5/A6 D-A3/ A3C D-A44/ A44C D-G39/ G39C D-K39/ K39C D-F5 D-J59 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F D-F5 D-J5 D-F59F D-F5W D-J59W D-F5BAL D-B5/B64 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F Auto switch model D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W
D DIN terminal DL DIN terminal with light DO DIN terminal (without connector, with gasket) Orifice diameter and Port Size Combinations T Conduit terminal Class Orifice diameter (mm) Port size 2 4 3 7 5 10 1/8 ( 6A) V V V V 2 1/4 ( 8A) V V V V 1/4 ( 8A) V V V V 3 3/8 (10A) V V V V V 1/2 (15A) V Connector 1/4 ( 8A) V V V V 3/8 (10A) V V V V V All class B coils come with surge
Hysteresis Switch operating position (ON) Auto switch reset position (OFF) Series MHS/MHSL Series MHSJ/MHSH (mm) (mm) Hysteresis (Max. value) D-M9(V) D-M9W(V) D-M9A(V)L MHS MHSL3 Hysteresis (Max. value) D-M9(V) D-M9W(V) D-M9A(V)L Auto switch model Auto switch model Air gripper model Air gripper model MHSJ3 MHSH3 16D -16D 0.5 0.5 MHS MHSL3 MHSJ3 MHSH3 20D -20D 0.5 0.5 MHS MHSL3 MHSJ3 MHSH3
1 1000 V = D 2 x L x (L) For the conductance, the equivalent conductance can be found in 8.
[115 VAC]*1 V V V V 4 220 VAC [230 VAC]*1 V V V V AC (50/60 Hz) t d Rated coil voltage DC 5 24 VDC V V V V 6 12 VDC V V V V + G Grommet (Lead wire length: 300 mm) V V V V D Type D (DIN terminal/With connector) V V V V Y Type Y (DIN terminal/With connector)*2 V V V V DO Type D (DIN terminal/Without connector) V V V V YO Type Y (DIN terminal/Without connector) V V V V + u f Light/ surge voltage
center Apparent power VA (B) 2 (A) 4 (B) 2 (A) 4 AC 200 V 2.3 (With indicator light: 2.4) 2.5 (With indicator light: 2.6) [2.7 (With indicator light: 2.8)] 220 V [230 V] 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) Surge voltage suppressor Diode (Non-polarity type: valistor) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 Indicator light LED In common between 110 VAC and 115
DC specifications of type "D" and "DO" is only available with 12 and 24 V DC.
to 63. 145
Auto Switch Mounting CP96 Series How to Mount and Move the Auto Switch