Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: ø6 One-touch Fitting, Elbow Type, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Compared to the ZSE20(F), ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. ZSE20B(F) is UL/CSA, CE and RoHS compliant, with an IP65 enclosure rating.
Vacuum sensing for air and liquid non-corrosive to 630 and 304 SST; 3 setting modes: 3-step, simple, function selection; 7 displayable units: MPa, kPa, kgf/cm2, bar, psi, inHg, mmHg; 2 switch outputs (NPN or PNP) plus 1 analog output (V or mA); Port sizes: 1/4 Rc, NPT or G (with M5 female); 1/8 Rc (male), 1/4 URJ or 1/4 TSJ; Bracket or panel mounting options
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: M5 Female Thread, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: M5 (M5 Female Thread)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Piping Specification: M5 Female Thread, Option 1: -, Option 2: -, Option 3: -
F 24 VDC 1/2 G DIN terminal 24 VDC L M 5 20A C37 N.C. With surge voltage suppressor 3/4 20 H 100 VAC C N.O. Stainless steel J 110 VAC 6 25A N.C. N P C37 Stainless steel 25 1 K 200 VAC D N.O. L 230 VAC 7 32A N.C. Q CAC408 35 32A Flange M Conduit terminal 24 VDC E N.O. With surge voltage suppressor N 100 VAC 8 40A N.C. R CAC408 40 40A Flange P 110 VAC F N.O. Q 200 VAC 9 50A N.C.
60 62 62 Applicable flange N Q L K J B C H F E D A N M 82 (92) 93 (103) 98 (108) N M 82 (92) 93 (103) 98 (108) M 90 (100) M 82 (92) 93 (103) 98 (108) Energized open Energized closed VXD2272 32A 40A 50A VXD2382 VXD2392 VXD2270 51.5 54.5 59 160 170 180 135 140 155 67.5 70 77.5 168 (185) 182 (197) 194 (209) 100 105 120 36 42 53 35 40 40 12 14 14 25.5 28 28 41.5 23 25.5 25.5 48 50 50 95 97 97
/Japanese 1pc.), Accessory Y strainer (40 meshes) 25A, Barrel nipple 25A Anchor brackets 2pcs.
Series VXP21/22/23 Dimensions Normally Closed: VXP2270/2380/2390 Normally Open: VXP2272/2382/2392 Grommet: G Conduit: C DIN terminal: D Cable 6 to 12 Conduit terminal: T Model Grommet Electrical entry Conduit Conduit terminal DIN terminal Q N 60 62 62 Applicable N Q L K J B C H F E D A flange M N 25.5 28 28 M 84 (94) 95(105) 106(117) N 41.5 44.5 44.5 M 84 (94) 95(105) 106(117) M 84 (94) 95
Connection threads R/NPT A E E H L1 L1 L2 M N Min. port size L1, L1 LVA N LQ3L11-M 4 1/8" 12.5 10 9 11 26 25 16.5 14 4 2.5 LQ3L12-M 3 2 LQ3L21-M 6 1/8" 18.5 17 16 16 33.5 32.5 22.5 20 4 4 LQ3L22-M 1/4" 16.5 6 LQ3L31-M 10 1/8" 24 LVH L2 M (A) LVD LVQ 4.4 4.4 LQ3L32-M 8 LQ3L33-M 10 1/4" 22 6.4 6.4 LQ3L34-M 8 LQ3L35-M 10 3/8" 21.5 10 7.5 LQ3L36-M 8 6.4 LQ3L38-M 1/2" 24.5 47.5 44.5 32.5 9.5 LQ3L41
M N M N M M N Q L K J H F E D C B A P Applicable thread Pc Normally open Normally closed VXP2270 VXP2380 VXP2390 VXP2272 1 43.5 46.5 52 51.5 54.5 59 53 60 71 67.5 72 81 48 50 50 95 97 97 62 64 64 125 132 150 128 (145) 144 (159) 160 (175) 26.5 30 35.5 57.5 60 69 23 25.5 25.5 35 40 40 92 (102) 103 (113) 114 (124) 25.5 28 28 84 (94 ) 95 (105) 106 (117 ) 41.5 84 (94) 95(105) 106(117) 60 62 62
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: P (w/Unit Selection Function, Initial Value psi), Piping Specification: N01 (NPT 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: Lead Wire w/Connector, 2m, Option 2: Panel Mount Adapter, Option 3: -