Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 70, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 90, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 15, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide / Cylinder with functions of thrusting and boosting, Environment, Applications: Standard, End Locking: -, Cushion: Rubber cushion, Operating Pressure

How to Order Connector Assembly DC : V200-30-4A100 VAC : V200-30-1A200 VAC : V200-30-2AAC other voltages: V200-30-3AWithout lead wire : V200-30-A (With connector and 2 pcs. of socket) Lead wire length Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm How to Order Include the connector assembly part number together with the part number for the plug connectors

(with 500 VDC) between the terminals and housing Standards and regulations CE marking, UL(CSA), RoHS PPS, FKM, CPVC Wetted materials Non-grease type Piping port size 4 25A union 30 A Without lead wire 270 g 325 g Weight With lead wire 355 g 410 g 1: Please refer to the chart of measurement range of ethylene glycol aqueous solution on page 32.

Centralized wiring and piping directions Specifications Max. number of outputs: 32 (Valve + Ejector) Valve stations: 2 to 24 stations (Max. number of outputs: 30, Depends on whether single or double) Ejector stations: 1 to 8 stations (Max. number of outputs: 16) Wiring and piping for valves and ejectors can be arranged in the same direction.

CP-L006ICP-LOHi jCP-i:015 10 5, 10, 1 5, 20 ,(25)~ 30 Tluhnlmfwrth pi~): CP-T006Ic P-TOlO lCP-T015 15 5,1 0,15, 20, (25 )~ 30 ItI Smm spacer is added to the 30mm stroke cylinder.

Refer to manifold ordering. 24 23 22 21 20 19 18 17 Terminal no. 28AWG 16 15 6 14 13 Red 12 11 10 9 8 7 26 2 25 1 30 (20P) 37.5 (26P) Connector terminal number 6 5 4 3 2 1 Triangle mark indicator position <26P> <20P> (15.6) Terminal no. Terminal no.

or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.

Rc G (ISO1179-1) NPT NPTF 64 1.6 N.C / N.O 284 0.5 Bracket on the right side 3 / 4 (20A) SGC3 170 1 M12 connector 109 1.6 440 0.5 1 (25A) SGC4 265 1 174 1.6 374 Coolant Blow Energy Saving Coolant Blow Energy Saving Coolant pump 30% Hydraulic pump, etc. 50% Air compressor 20% Reduction of electric power consumption of the coolant pump Electric power consumption by purpose (SMC research)

Nil W 2-5-5 Base Mounted Series VQ4000 Plug-in Type Conduit terminal 2 position single: VQ410 0 1 23.5 23.5 50 158 50 90 108 158 Indicator light 11(12.5) 11(12.5) 5 3 2(B) port 4(A) port 9 4 2 38 48 10.5 1 11 A B 38 24.6 48 4 2 A 13.5 13.5 30 45 2-5.6 Mounting hole 14 5 1 3 12 30 45 2-5.6 Mounting hole 5-Rc 1/4, 3/8 (5(R1), 3(R2) port Rc 1/4) Manual override Bottom ported drawing 27 4(A),

Not required Unrestricted 150/30 Note 1) Be certain that pressure within operating pressure range be supplied to supply port, because return pressure is introduced from supply port {1(P)} for activation. Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.

Related Products: Silencer (Series AN) Over 30 dB noise reduction Sufficient effective area Exhaust Cleaner (Series AMC) Provides a silencing capability and an oil mist recovery function. Can also be used in a centralized piping system.

Refer to manifold ordering. 23 24 21 22 19 20 17 18 Terminal no. 28AWG 15 16 6 13 14 Red 11 12 9 10 7 8 26 2 25 1 30 (20P) 37.5 (26P) Connector terminal number 5 6 3 4 1 2 Triangle mark indicator position <26P> <20P> (15.6) Polarity Terminal no. Polarity Terminal no. () L SOL. A SOL. A (+) () (+) 1 1 Station 1 Station 1 SOL. B SOL. B (+) () () (+) 2 2 SOL. A SOL.

Ambient and fluid temperature (C) Response time (ms) (1) (at the pressure of 0.5 MPa) 0 (No freezing) to 60 OFF AC 30 or less ON AC 30 or less DC 30 or less DC 40 or less Max. operating frequency (Hz) 3 Lubrication (2) Required (Equivalent to turbine oil Class1 ISO VG32) Manual override Yes (Non-locking) Mounting orientation Unrestricted 150/50 Impact/Vibration resistance (m/s2) (3) Note

For clean type (11-) or secondary battery (25A-) type actuator Search without entering 11or 25A-, and select the actuator for which the part number after 11or 25Amatches. e.g.) For 11-LEFSH16A-100BR, enter "LEFS16A-100" and select LEFS16A-100.