SMC Corporation of America
Elite Part Number Search
Search Results "11-CDUJB10-10D-F8PL"

Clean Room: 11 (Vacuum Suction Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 10mm, Stroke: 6mm, Rod End Thread: M (Rod End Male Thread)

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: Rod End Male Thread, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 8mm, Rod End Thread: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 15mm, Rod End Thread: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Clean Room: Vacuum Suction Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 10mm, Stroke: 4mm, Rod End Thread: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 4, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Stainless steel + NBR Scraper 20 Replacement Parts Finger Standard Model Tapped on upper and lower faces Tapped on all faces Seal kit Scraper assembly Grease pack Description MI-A0801-10 MI-A0802-10 MI-A0803-10 MIS8-PS MIS8-10D MIS8-20D MIS12-10D MIS12-20D MIS12-30D MIS20-10D MIS20-20D MIS20-30D MIS25-30D MIS25-50D MIS32-30D MIS32-50D MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203

Stainless steel + NBR Scraper 20 Replacement Parts Finger Standard Model Tapped on upper and lower faces Tapped on all faces Seal kit Scraper assembly Grease pack Description MI-A0801-10 MI-A0802-10 MI-A0803-10 MIS8-PS MIS8-10D MIS8-20D MIS12-10D MIS12-20D MIS12-30D MIS20-10D MIS20-20D MIS20-30D MIS25-30D MIS25-50D MIS32-30D MIS32-50D MI-A0803-10 MI-A0803-20 MI-A1203-10 MI-A1203-20 MI-A1203

Clean Series: Vacuum Suction Type, Bore Size: 10mm, Finger Option: Through-holes in Opening/Closing Direction, Standard Type, Auto Switch: Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 3m

Magnet: D (Built-in Magnet), Mounting Direction: B (Through-hole: ø4 to ø10; Lateral Mounting: ø12 to ø20), Bore Size: 10mm, Stroke: 10mm, Rod End Thread: Rod End Female, without Thread for ø4, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made To Order Option: XB24, High Durability

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10mm, Stroke: 10mm, Action: D (Double Acting)