Clean Series: Relief Type, Magnet: Built-in, Mounting: Axial Foot, Cushion: Rubber Bumper, Bore Size: 20mm, Stroke: 100mm, Port Thread: Female Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Clean Series: Relief Type, Magnet: Built-in, Mounting: Basic Style, Cushion: Rubber Bumper, Bore Size: 20mm, Stroke: 100mm, Port Thread: Female Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Clean Series: Relief Type, Magnet: Built-in, Mounting: Basic Style, Cushion: Rubber Bumper, Bore Size: 40mm, Stroke: 100mm, Port Thread: Female Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Clean Series: Relief Type, Magnet: Built-in, Mounting: Basic Style, Cushion: Rubber Bumper, Bore Size: 80mm, Stroke: 100mm, Port Thread: Female Rod End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Clean Series: Relief Type, Magnet: None, Series: Standard, Mounting: Front Flange, Bore Size: 63mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: -, Lead Wire or Prewired Connector: -
Clean Series: Relief Type, Magnet: Built-in, Series: Standard, Mounting: Front Flange, Bore Size: 40mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: -, Lead Wire or Prewired Connector: -
Clean Series: Relief Type, Magnet: Built-in, Series: Standard, Mounting: Front Flange, Bore Size: 63mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: -, Lead Wire or Prewired Connector: -
Clean Series: Relief Type, Magnet: Built-in, Series: Standard, Mounting: Basic Style, Bore Size: 63mm, Port Thread: Rc, Stroke: 100mm, Auto Switch: -, Lead Wire or Prewired Connector: -
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 1.0~, Cushion: Rubber bumper at both ends, Port
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Clean Room, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~0.7, Cushion: Rubber bumper at both ends, Specification: Clean Series (relief type), Port
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of t, Cylinder, Guide, with Auto Switch, GUIDED CYLINDER, 2.24 lb
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body (except port face), allowing mounting of various brackets. Optional auto switches
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 40MM MGF CLEAN ROOM, ACTUATOR, 40MM MGF CLEAN ROOM, 7.55653 lb
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body *, allowing mounting of various brackets. Optional auto switches can be mounted
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body *, allowing mounting of various brackets. Optional auto switches can be mounted
Series MGF guide tables are low profile, compact cylinders which utilize a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting is possible from 2 directions. A built-in non-rotating mechanism prevents rotation of the table top. T-slots are provided on 3 faces of the MGF body *, allowing mounting of various brackets. Optional auto switches can be mounted
Connection: Insert Fitting, Connection Size: 10 (Insert Fitting Ø10), Nozzle Diameter: 100 (Ø1), Number of Holes: 4 Holes
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
The series MGG guided cylinder is ideally suited for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional cylinder, linear motion guide, and non-rotation device. Features include built-in shock absorbers, finite stroke adjustment, bumpers, and switch capability. Other features include: Slide or ball bushing bearings available