Body Size: 20, Backflow: w/Backflow Function, Thread: NPT, Port Size: 1/8, Mounting: w/o Mounting Option, Set Pressure: 0.02 to 0.2MPa, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Unit: Name Plate and Pressure Gauge in Imperial Units: psi
Body Size: 20, Backflow: w/o Backflow Function, Thread: NPT, Port Size: 1/8, Mounting: w/o Mounting Option, Set Pressure: 0.02 to 0.2MPa, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Unit: Name Plate and Pressure Gauge in Imperial Units: psi
Body Size: 20, Back Flow: w/o Backflow, Thread: NPT, Port Size: 1/8, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (and MPa)
Body Size: 20, Back Flow: w/o Backflow, Thread: NPT, Port Size: 1/8, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: w/Bowl Guard, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Z [Product: psi, °C; Pressure Gauge: psi (
Output Specification: PNP Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Panel Mount Adapter, Option 3: -
Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Panel Mount Adapter, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 1 Output, Unit Specification: w/Unit Selection Function, Initial Value psi, Piping Specification: NPT 1/8, Option 1: w/o Lead Wire, Option 2: Panel Mount Adapter, Option 3: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w/Flow Adjustment Valve
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment Valve
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Bracket for w
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Fixed SI Unit, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -