Customers do not need to apply for a license to use this equipment. Be sure to comply with the following precautions. Do not disassemble or modify the product. Disassembly and modification are prohibited by law.
Do not use in locations where there is splashing or spraying of oils and solvents. Since this unit is open type, if water or oil, etc. make an ingress etc., the internal circuit may be corroded and result in a malfunction or damage. 2. Ground the piping when induction noise is expected to be generated from piping.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Specifications x100 IP address x 10 1 DIP SW Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.
Specifications Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Technical documentation giving detailed configuration information and the GSD file can be found on the SMC website (URL http://www.smcworld.com). Specifications Do not operate in an atmosphere containing flammable or explosive gases.
Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Connect valve manifold to the SI unit. Refer to the EX260 series valve manifold section in the valve catalogue for valve manifold dimensions. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.
Do not apply excessive force or impact. This will not only damage the product but also decrease its performance and life expectancy. It is not possible to disassemble the bonnet assembly of this product. If the components and assembly are damaged, or damage is expected, exchange the bonnet assembly itself. Do not disassemble the parts that are not explained in this operation manual.
Handling notes 6.1 Cautions for handling of the vertical auto switch unit (1) Be sure to connect a load to the switch before turning the power supply on. (2) Do not let objects drop onto or dent the product or subject it to strong impact when handling. (3) Do not use the product in the presence of a strong magnetic field. (4) When using two or more cylinders with auto switches closely in
11H9 Depth 1.5 35 Positioning pin hole MHZ2 47.5 9 MHZJ2 58 15 MHQ Auto switch mounting groove position M5 X 0.8 (Finger opening port) MHL2 MHR 3 O 13 MHK S MHS 3 4 23 7 M5 X 0.8 (Finger closing port) 2 MHC2 MHT2 MHY2-10D2 Opening/closing direction through hole type 43.4 MHY2 (Hole for mounting attachment) MHW2 6 0.005 0.025 3 6 MRHQ 12 Auto switch (Limited area for mounting attachment) Do
Do nol loosen the recessed head screw on the top of the sensitivity adiusting screw because ii is lor prelenting the screw trom slipping otf. @
Troubleshooting Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Manifolds SJ2000/3000, S0700 series : Refer to the catalogues and operation manuals for details on the solenoid valves and manifolds. How to mount the manifold 1.
No.6 No.5 No.8 No.7 No.10 No.9 Red flashing Wrong switch setting, Parameter writing error Green On Bus-off state, Duplicate MAC ID 16 32 4 8 1 2 Red flashing Off Green On I/O Connection is in the Timed-Out state Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result.
Bit: 7 0 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Bit No. 6 4 6 4 2 0 0 0 Solenoid on side A 0 2 4 6 8 16 28 30 Output No.
Do not connect multiple NFC readers / writers to a PC. Connection details using the I/O Configurator for NFC and wireless unit To use a wireless system, it is necessary to "pair" a Wireless Base and Remote. Configure this using the I/O Configurator (NFC version).
Tightening Torque for Stroke Adjustment Unit Holding Bolts Unit: Nm Bore size (mm) 25 32 40 Tightening torque End lock 1.8 3.5 Operating direction 5.8 L R Caution R L R L R L R L Do not operate with the stroke adjustment unit fixed in an intermediate position.
Do not move the cover upward inadvertently during end plate installation.
Do not block the bleed hole. If the bleed hole is blocked, the product will not operate properly. VBA VBAT AP100 875
Please do not apply force to the coil and frame when installing the piping and valves. If they receive 10 N or more of force, a malfunction may occur. 3. Do not pull the lead wire with excessive force. Applying 10 N or more of load may result in broken wire or contact failure. Manual Override Caution 1.
Do you have a process requiring cost-efficient automation? Do you have a new series of safety features to implement? In fact, do you need another pair of hands in order to solve that troublesome domestic project?
Tidy Un-friendly What do you think to the manual presentation? ! ! ! Yes Not too bad Unusable Are the explanations understandable? Which explanation was most difcult to understand: . . ! ! Are there any diagrams which are not clear? Yes No If so,which:. ! ! ! What do you think to the manual layout?