Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 1000mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 3m, Controller Type: LECA6 PNP, Servo Motor

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 800mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 3m, Controller Type: LECA6 PNP, Servo Motor

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 150mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type: LECA6 NPN, Servo Motor, Step Data Input Type

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 150mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type: LECPA, NPN, Pulse Input Type, I/O Cable Length

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 400mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type: LECA6 NPN, Servo Motor, Step Data Input Type

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 400mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller Type: LECPA, NPN, Pulse Input Type, I/O Cable Length

Series: Clean Series Ball Screw Drive, Accuracy: Basic Type, Size: 40, Motor Type: Step Motor (Servo/24 VDC), Lead: LEFS16, 5mm; LEFS25, 6mm; LEFS32, 8mm; LEFS40, 10mm, Stroke: 200mm, Motor Option: w/o Lock, Vacuum Port: Left, Positioning Pin Hole: Body Bottom, 2 Locations, Actuator Cable Type: R [Robotic Cable, (Flexible Cable)], Actuator Cable Length: 8m, Controller Type: JXC, Step Motor

Accuracy: Basic Type, Size: 40, Motor Mounting Position: In-line, Motor Type: Step Motor (Servo/24 VDC), Lead Screw: LEFS16: 5mm, LEFS25: 6mm, LEFS32: 8mm, LEFS40: 10mm, Stroke: 150mm, Motor Option: w/o Option, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type: Standard Cable, Actuator Cable Length: 3m, Controller/Driver Type: JXC, Step Motor Controller, I/O Cable, Communication

After setting (500) Forced fully-close / fully-open to (oFF), made setting by Value setting (vALU), Ratio setting (rAtE), and Operation setting (ACt)*20. 19: Set values are stored when values are changed.

70500mm/s 5,12 5,12 6 4,5 CE1B12 () (500 3000) 7 14 69+ 93.5+ CE1B20 () 2x5.5 (500 3000) 4xM6x1 15 14 78+ 106+ CE1B32 4x5.5 (500 3000) 8xM6x1 20 90+ 131+ () 14 CE1B40 (500 3000) 4x5.5 8xM6x1 20 136+ 177+ 14 () CE1B50 (500 3000) 4x6.6 8xM8x1.25 20 144+ 193+ () 14 CE1B63 4x9 8xM10x1.5 20 (500 3000) 145+ 194+ () 14 2004 12 A 2014.4 B 2017.8 C 2017.11 4-14-1, Sotokanda

500 LEFS25 900 500 Please aspirate it from the port on both sides when aspirating 50 /min(ANR).

Software setting mode Hardware setting mode Software setting mode MAC ID: 0 MAC ID: 0 MAC ID: 63 Communication speed: 125 kbps Communication speed: 500 kbps Communication speed: 500 kbps The default output setting for when communication stops is 0 (all outputs to be cleared).

E PE Item Spec. 500 500 Facility water temp. 35deg.C RS-232C RS-485 Model No.

Enclosure IP40 Operating temperature -5 to 50C range Environmental resistance Withstand voltage 1000 VAC for 1 minute between terminals and housing 50M or more between terminals and housing Insulation resistance (with 500 VDC megger) Temperature characteristics 2% F.S.

Enclosure IP40 Environmental Withstand voltage 1000 VAC for 1 minute between terminals and housing resistance 50M or more between terminals and housing Insulation resistance (with 500 VDC megger) Temperature characteristics 2% F.S.

Refrigerant Air connection 300 2.2 IDU3D 350 Series IDU High inlet air temperature type Rated temperature of 50 to 60C Rc 3/8 60C 430 3.7 IDU4D 500 Small Medium Small Medium Large R134a 1 to 4 R 1/2 640 5.5 IDU6D 750 55C R 3/4 Air cooled Air cooled 850 7.5 IDU8D 1000 IDU11D R134a 1300 11 R 3/4 1500 IDU11C 1300 55C 2400 IDU15C 15 2050 R 1 3700 IDU22C/22C1 22 3150 R22 5 to 8 6100 IDU37C/37C1

(Locking type is for VZ300/500 only.) Coil DC V100 Non-locking push type must be pressed in the direction of the arrow.

actuation 600 500 400 300 200 100 0 SX3140-01 900 800 700 600 500 400 300 200 100 0 SX5140-02 900 800 700 600 500 400 300 200 100 0 SX7140-03 It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve with being fully open.

Body Ported Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB/CA1 Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQZ1121-C6 Courtesy of Steven Engineering,

Cylinder Speed Chart Bore size Series CJ2 Pressure 0.5 MPa Load factor 50% Stroke 60 mm Series CM2 Pressure 0.5 MPa Load factor 50% Stroke 300 mm Series MB Pressure 0.5 MPa Load factor 50% Stroke 500 mm 6 10 16 20 25 32 40 40 50 63 80 100 Series Average speed (mm/s) 800 700 600 500 400 300 200 100 0 It is when the cylinder is extending that is meter-out controlled by speed controller which