A grease pack (10 g) is included. If an additional grease pack is needed, order with the following part number.
EXW1 EXW1 Up to 100 m V.1.0 / V.2.0 Available *1 EXW1 EXW1+EX600 *2 V.1.0 Not available EXW1 EX600 Up to 10 m V.1.0 Not available EX600 EXW1 Up to 10 m V.1.0 Not available Available *3 EX600 EXW1+EX600 Up to 10 m V.1.0 Not available Available *3 EX600 EX600 Up to 10 m V.1.0 Not available Available *1 Available in protocol V.2.0. *2 Up to 100 m between an EXW1-series Base and Remote, and up
As an example, for a travel of 100 (mm) Travel distance of the actuator per 1 pulse = 0.001 (mm) *1 100 (mm)/0.001 (mm) = 10 (pulse) If the stroke end signals (LSP, LSN) are not turned ON, an alarm may occur.
This value can be used for the selection of the power supply. *9 With lock only. *10 For an actuator with lock, add the power consumption for the lock.
Note 10) A reference value for correcting an error in reciprocal operation. Switch and Acceleration Note) Table 2 Switch no. Acceleration [mm/s2] 0 250 1 500 2 1000 3 1500 4 2000 5 2500 6 3000 7 4000 8 5000 9 6000 10 7500 11 10 12 12500 13 15000 14 17500 15 20 Note) The factory default setting for the switch is No.0.
Auto Switch Rotation range / Actuation / most sensitive position D-M9 auto switch D-F8 auto switch Size Rotating Operation Operation A B angle Hysteresis Hysteresis angle angle (mm) (mm) angle angle m m 90 20.5 16.5 05 46 10 20 10 180 23.2 19.2 90 22.4 18.4 1 41 10 15 10 180 25.6 21.6 Operating angle m: Value of the operating range Lm of a single auto switch converted to an axial rotating
Product number Suitable screws Tightening torque Thread depth PF3A703H Equivalent to M4 1.5 Nm 10 7 PF3A706H Equivalent to M5 3 Nm 10 8 PF3A712H Equivalent to M6 5.2 Nm 10 9 Prepared by the user.
Air flow SW:1 10 10 Air flow SW:10 5 5 Air flow SW:10 0 0 0 200 400 600 800 1000 1200 1400 1600 0 200 400 600 800 1000 1200 1400 1600 Installation distance mm Installation distance mm 28 Doc.
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
AN103-01 AN203-02 AN303-03 AN403-04 5-10-3 Silencer BC Sintered Body Type Series AN Specifications/Model Ideal for the exhaust of a compact valve or pilot air.
8 (left side) One-touch fitting 10 (left side) Mixed 02R 03R 02L 03L 02Y 03Y C6R C8R C10R C6L C8L C10L Control equipment Symbol Nil A AP M MP F G C E Air filter with auto drain 10 stations 10 Air filter with manual drain Note) When equipped with control unit, one or two stations are used for mounting.
15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Specifications Suction flow rate of vacuum suction type (Reference
The minimum order quantity is 10 pieces. Order in multiples of 10.
Otherwise, chattering will occur. 9: This function is available when the model includes an analogue output. 10: When selecting 0 to 10 V, refer to the analogue output graph for the allowable load current. 11: Standard condition (STD): 20 [oC], 101.3 [kPa] (Absolute pressure), 65 [%R.H.]
If an instantaneous flow of 10 L/min continues for 5 minutes, the accumulated flow will be 5 x 10 = 50 L. Accumulated flow external reset A function to reset the accumulated flow to "0" when an external signal is input. A type of output where a pulse is generated every time a predefined accumulated flow passes.
Minimum necessary energizing time for self holding is 10 ms. 3. There is no problem as long as the product is used normally in an ordinary operating location. If the product is used in an environment where vibration larger than 30m/s2 or strong magnetic field is present, consult with SMC. 4.
An error code is returned if an instruction code outside the range set in parameter No.
(Supply pressure 0.3 MPa) External air inlet Compressed air External air inlet Yes None Reduced by 50% Air consumption flow rate L/min (ANR) 10 10 Ionized air Discharge time sec 2.5 2.5 5 Compressed air Improved 6 times Ionized air flow velocity m/s 0.4 At 300 mm distance External air inlet External air Neutralizing static electricity from an electric substrate Neutralizing static electricity
Connector wiring diagram (mixed wiring) Connector type manifold 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing
An injury or failure can result. 1. Pay attention to the length of time that a switch is ON at an intermediate stroke position.