Operating Environment Do not use in an atmosphere having corrosive gases, or where there is direct contact with this. Do not use in dusty locations or where water or oil, etc., splash on the equipment. Do not use in a place subject to heavy vibration and/or shock. Speed Adjustment To make a speed adjustment, gradually adjust starting from the low speed end.
Do not apply an excessive force to loosen the cushion needle.
Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.
Precautions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use.
Do not obstruct the exhaust port of the ejector. Do not cover the exhaust port. Otherwise, vacuum is not generated. Do not block the exhaust port to release the work piece. This can damage the vacuum ejector. 8.
Do not apply a load in excess of the operating limit. 1. Do not allow the table to hit the end of stroke. The internal stopper can be broken. Select a suitable actuator by load and allowable moment.
Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.
Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.
Note12) Do not allow collisions at either end of the table travelling distance. Additionally, when running the positioning operation, do not set within 2mm of both ends. Note13) Consult with SMC for the manufacture of intermediate strokes.
TQ1230001-OM103-A grip success: default output DO[101] grip failure: default output DO[102] workpiece drop detection: default output DO[103] * Digital output port can be selected within DO[101] DO[112] * If you select the same digital output port for different status signals, a warning message will be displayed. 3.2.
Do not Do not use in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. The product is not designed to be explosion proof. Do not Do not use the product for flammable or highly permeable fluids. Fire, explosion, breakage or corrosion can result. Do not Do not use the product in a place where static electricity is a problem.
Do NOT operate the product without the cover panels mounted. Do NOT work on the parts inside the product unless you have been trained for the product service. Do NOT work inside this product unless you have been trained to do so. High temperature warning This symbol stands for danger of burns. The product has surfaces that can reach high temperatures during operation.
Do not apply excessive lateral load to the piston rod.
Do not disassemble, modify or repair the controller or its peripheral devices. 4. Do not put anything conductive or flammable inside the controller. Otherwise, fire can result. 5. Do not conduct an insulation resistance test or insulation withstand voltage test. Maintenance Warning Wiring Warning 1.
Do not use the product in an environment subjected to cyclic temperature changes. It will cause failure of the controller or its peripheral devices. 97 - 6. Do not use in a place where surges are generated.
Consult P/A when the use in such environment is required. 3.Do not use in direct sun light. 4.Do not use in environment where there is heat source. With shock absorber 2.
Do not use the product in the presence of a magnetic field. Malfunction can result. Do not let foreign matter, such as wire debris, get inside the product. Otherwise it can cause damage or malfunction. Do not use the product in an environment that is exposed to temperature cycle.
Do NOT operate the product without the cover panels mounted. Do NOT work on the parts inside the product unless you have been trained for the product service. Do NOT work inside this product unless you have been trained to do so. High temperature warning This symbol stands for danger of burns. The product has surfaces that can reach high temperatures during operation.
Do not disassemble the cables. Use only specified cables. 3. Do not connect or disconnect the wires, cables and connectors when the power is turned on. Caution 1. Wiring securely. Do not apply any voltage to the terminals other than those specified in the Operation Manual. 2. Wire the connector securely. 3. Take appropriate measures against noise.