: [12 to 24] 12 to 24 ±10%, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: Negative pressure [0 to −101 kPa], Option: Without connector, Analog Voltage Output(V): 1 to 5 V DC, Accuracy(%F.S.): ±2, Female thread compatible: With M5 female thread

: [12 to 24] 12 to 24 ±10%, Pipe Connection Direction: [Down] Down, Connecting Tube Diameter: -, Display: No, Lamp: No, Acquired Standards: CE, Protection Structure: IP40, Application: For compound pressure [-100 to 100 kPa], Option: Without connector, Analog Voltage Output(V): 1 to 5 V DC, Accuracy(%F.S.): ±2, Female thread compatible: With M5 female thread

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3-SCREEN HIGH PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 43.00000 lb

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple. PRESSURE SWITCH, ISE1-6. 3 SCREEN HI PRECISION DIG PRESS SWITCH. 22.00000 lb. N59.

Solenoid on side A 0 2 4 6 8 16 28 30 2 3 1 SV24 V +24 V for valve 5 2 SV0 V 0 V for valve Side D Side U URL http://www.smcworld.com 1 4 3 SW24 V +24 V for input (SI unit side) Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 SW0 V 0 V for input 4 Output No.

All solenoid valve outputs are reset to zero. 2 SV0 V 0 V for valve 3 SW24 V +24 V for input 1 4 5 SW0 V 0 V for input 4 Mode setting 5 FE Ground URL https://www.smcworld.com Mode SW1-10 0 H / W mode Set address and communication speed by SW1 to 8.

Auto switch 1 Auto switch 1 Blue Blue Brown Brown Auto switch 2 Auto switch 2 Blue Blue Load voltage at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Load voltage at OFF = Leakage current x 2 pcs. x Load impedance = 1 mA x 2 pcs. x 3 k = 6 V Example: Load impedance is 3 k. Leakage current from auto switch is 1 mA.

06 to 08 AL-197H-V 10 to 12 FKM-70 or EPDM-70 AL-198H-V Phosphoric ester 16 AL-199H-V 20 to 24 AL-200H-V 28 to 32 AL-201H-V Note) The material of seals (AL-196H-V to AL-201H-V) is EPDM-70.

First find the ratio of the discharge rate for fresh water when viscosity is 15mPa s from the graph to the left. It is determined to be 48%. 2. Next, the viscosity of 15mPa s and the discharge rate of 200l/min in the required specification example are converted to the discharge rate for fresh water.

First find the ratio of the discharge rate for fresh water when viscosity is 15mPa s from the graph to the left. It is determined to be 48%. 2. Next, the viscosity of 15mPa s and the discharge rate of 200l/min in the required specification example are converted to the discharge rate for fresh water.

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread

Rated Pressure Range: 0.00 to -14.69 psi, Piping: M5 x 0.8, Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -

Piping: M5 x 0.8, Female Thread, Output Specification: PNP Open Collector 2 Outputs+Analog Current/Auto-shift Switching, Unit Specification: -, Option: -, Calibration Certificate: -, Lead Wire: -

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)