SMC Corporation of America
Elite Part Number Search
Search Results "CDQ2B63-35DMZ-M9BS"

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Foot, Port thread type: Rc, Body Options: Rod

Magnet: D (Built-in Magnet), Series: J2, Mounting: B (Basic), Bore: 16mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type: B (Band Mounting)

Magnet: D (Built-in Magnet), Series: J2, Mounting: B (Basic), Bore Size: 16, Stroke: 100mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto Switch Mounting Type

Magnet: D (Built-in Magnet), Mounting: G (Head Flange), Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Made to Order: XC4 (w/Heavey Duty Scraper)

Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Type: Pneumatic, Bore Size: 80mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke 1: 10mm, +: +, Stroke 2: 10mm, Body Option: with Rubber Bumper, Auto Switch Groove: None (for 12-25 Bore w/o Magnet), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead

Magnet: D (Built-in), Series: J2, Mounting: L (Single Foot), Bore Size: 10mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Pivot Bracket: None, Rod End Bracket: V (Single Knuckle Joint), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.), Auto

Magnet: Built-in Magnet, Mounting: Head Flange, Tube Material: Aluminum Tube, Bore Size: 50mm, Thread: Rc, Stroke: 400mm, Bellows/Cushion: Cushion Both Sides, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Made to Order: w/Heavey Duty Scraper

Magnet: Built-in Magnet, Series: J2, Mounting: Basic, Bore: 16mm, Stroke: 150mm, Cushion: Rubber Bumper, Head Cover Port Location: Perpendicular to Axis, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc., Auto Switch Mounting Type: Band Mounting

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~1, Cushion: Rubber cushion, Auto Switches: M9B, Lead

Magnet: D (Built-in), Mounting: B (Basic), Size: 40 (Equiv. Ø40 Piston Area), Port Thread Type: M thread: ø25, Rc: 32 to 63, Stroke: 35mm, Rod End: M (Male Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Mounting Bolt: None, Rod End Bracket: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number

Magnet: D (Built-in Magnet), Mounting: B (Through Hole [Standard]), Bore Size: 32mm, Port Thread Type: Rc; M Thread: 12 to 25, Stroke: 35mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (12 to 25, 2 surfaces; 32 to 40 4 surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m or None in the Case of No Switch, Number: 2 pcs. or None in the Case of No Switch

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 35mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)