Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.
Auto Switch Groove 4 x 4.2 Bore size A B 10.3 13 15 18 21 23 27 25 35 27 4 x 3 10 16 20 25 32 1252 Free Mount Cylinder for Vacuum Series ZCUK Proper Auto Switch Mounting Position (Detection at stroke end) and Its Mounting Height D-M9 D-M9W D-A9 ZA ZX ZR ( ): Denotes the values of D-A93.
For 90 rotation Single vane (S): 80 to 100 adjustable Double vane (D): 85 to 95 adjustable A B 180 Adjustment range of adjustment bolt (A) Adjustment range of adjustment bolt (B) 10 10 22.5 DSize Allowable radial load (N) Allowable thrust load (N) Allowable moment (Nm) 1 10 15 20 0.3 A B Positioning pin hole 3 15 30 40 0.7 Adjustment bolt (A) Adjustment bolt (B) 7 30 60 50 0.9 20 For 180
Auto switch groove positions (mm) B 6.9 8.8 13.7 17.1 A 10 14 19 26 Bore size (mm) 6 10 16 20 4-4.2 Auto switch mounting groove B A 38
B MY CY 22 (20) MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com A CX D-A9V D-M9V D-F9WV D-X 20( ): Denotes the values of D-M9V, D-F9WV. 5(7) B W Data D-A9, D-A9V D-F9W, D-M9 D-F9WV, D-M9V Bore size (mm) A A W B W B A W B 6 12.5 3.5 (6) 16.5 7.5 2.5 16.5 5.5 2.5
When the temperature of the circulating fluid is set to lower than 10oC, use a 15% aqueous solution of ethylene glycol. Tap water may freeze in the thermo-chiller, leading to malfunction. 15% aqueous solution of ethylene glycol When a 15% aqueous solution of ethylene glycol is used, prepare the ethylene glycol aqueous solution separately.
-Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: (1 : ) JIS B 8433: 2) 1) 2) 3) 1. 2. 3. 4) 1. 2. 3. 4. 2 - No.ZQ-OM01401-B /ZQA / *3) 1)1 1.5 2) 3) *3) 1 1 () 3 - No.ZQ-OM01401-B () -() 4 - No.ZQ-OM01401-B 1.
Auto switch a c b d Proper Mounting Position (mm) D-Z7/Z80 D-Y59/Y7P D-Y69/Y7PV D-Y7W D-Y7WV Auto switch model D-M9 D-M9V D-M9W D-M9WV D-A9 D-A9V Proper Mounting Position (mm) A B A 15 19.5 24.5 B A 14 18.5 23.5 B Bore size 63 80 100 a b 14 18 17 c 20 24 23 d Auto switch model 15 18 22.5 19 23.5 28.5 11 14 18.5 10 13 17.5 D-A9 D-M9 D-M9W 2 6 5 8 12 11 Note) Adjust the auto switch after confirming
Setting: Operate the NFC-B preferentially using the protocol used. Select the icon. (Windows7 is used in this Operation Manual) (2) Double-click the [NFC port/PaSoRi] icon on the control panel to display the setting window. Select [NFC-B] only for [Detectable cards].
16.5 19.5 B 7.5 9.5 10.5 10.5 14.0 17.0 A 33.0 32.0 34.0 27.5 31.5 32.0 B 12.5 14.5 15.5 15.5 19.0 22.0 A 26.5 25.5 27.5 21.0 25.0 25.5 B 6.0 8.0 9.0 9.0 12.5 15.5 A 27.5 26.5 28.5 22.0 26.0 26.5 B 7.0 9.0 10.0 10.0 13.5 16.5 B 4.5 6.5 7.5 7.5 11.0 14.0 A 27 20.5 24.5 25 B 8.5 8.5 12 15 20 25 32 40 50 63 Note) When setting an auto switch, confirm the operation and adjust its mounting
VQZ235 Rubber 12.6 (0.7) 15 or less 20 or less 53 VQZ200 VQZ225 Metal 10.0 (0.55) 14 or less 18 or less N.O. VQZ245 Rubber 12.6 (0.7) 15 or less 20 or less VQZ315 Metal 16.2 (0.9) 17 or less 22 or less N.C. VQZ335 Rubber 21.6 (1.2) 25 or less 33 or less VQZ300 77 VQZ325 Metal 15.3 (0.85) 17 or less 22 or less N.O.
30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 3 5 11-/22-MXP12 11-/22-MXP12 11-/22-MXP16 11-/22-MXP16 99 Air slide table MXP/MXPJ6 11221122Dimensions / MXPJ6 5 C 11-/22-MXPJ6-5 Depth 2.5 2.5 7 H 5 10.05 3 3.5 4M3 x 0.5 depth 3 +0.030 0 D B 16.5 3.5 18 14 13 20 6 +0.030 0 Depth 2.5 2.5 6 E 5 2-M4 x 0.7 Piping port F QL 6 13.5 Prepared hole diameter 3.3
Drain cock Oil bowl B' C C Drain cock Drain guide (A) (B) Rc , NPT, G Mounting bracket Port size Model C B A Drain piping F G H J K L B' D E 6 6 1/4 female thread M3 x 0.5 1 4 2.3 15 12 20 50 73 AMC220 40 56 88 100 22 Depth 8 Body size A B C M3 x 0.5 71 88 101 101 121 55 63 83 96 96 116 1 4 3 8 , 56 75 102 118 135 153 AMC320 75 120.5 140.5 2.3 15 20 30 50 123.5 24 55 2 3 5 6 8 9 Depth
state auto switch D-M9B, D-M9N Reed auto switch D-A93 (mm) (mm) Stroke (mm) 20 41 29 47 35 Stroke (mm) 20 45 25 51 31 Auto switch operating range Auto switch operating range 15 40.5 20.5 Model Model 25 50.5 30.5 30 59 39 10 35 15 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B A B A B A B 11-/22-MXP10 11-/22-MXP10 11-/22-MXP12 11-/22-MXP12 3 5 11-/22-MXP16 11-/
Specifications Item Specifications Power supply voltage: 24 VDC 10%, Current consumption: Rated 2 A (Peak 3 A) Note 2) Power consumption: 48 W (Maximum 72 W)Note 2) Power supply Note 1) Parallel input 6 inputs (Optically isolated) Parallel output 4 outputs (Optically isolated, open collector output) Step data 15 points Position display output Note 3) A-phase and B-phase pulse signals, RESET
Double acting PA PA B A PB B A With by-pass Suck back valve Manual Operation-Series LVH N.C. Double acting P PA PA Locking and non-locking types available B A B A PB B A Integral fitting type/Threaded type Manifolds Main applications and fields For shut off For air bleeding N.C.
IDH Data Condensed Water Calculation 45 Atmospheric pressure 15psi (0.1 MPa) 40 Relative humidity 100% Amount of moisture in air (g/m3) 35 29 (0.2) 44 (0.3) 58 (0.4) 73 (0.5) 87 (0.6) 102 (0.7) 80% 60% 116 (0.8) 40% 30 25 145 (1.0) Amount of condensed water CH 18.23.0=15.2 g/m3 20% 20 203 (1.4) B C D 232 (1.6) 15 10 5 G H 0 E A F 4 (20) 14 (10) 32 (0) 50 (10) 68 (20) 86 (30) 104 (40) 122
Normal output Reversed output P_1(P_2)=A-(A-B)/4 n_1(n_2)=B+(A-B)/4 A = Maximum pressure H_1(H_2)= (A-B)/2 H_1(H_2)= (A-B)/2 B = Minimum pressure If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. -46No.PS-OMW0012-C [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
Bracket A (Part No.: ZS-50-A) Bracket B (Part No.: ZS-50-B) -15No.PS-OMY0007-A Piping After hand tightening, tighten the fitting using a spanner on the flat surfaces of the fitting. The tightening torque must be 15 to 20 Nm.