MG Bore size (mm) 40 Bore size (mm) 40 Model Model 50 63 80 100 50 63 80 100 MGP D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B6 D-B59W D-G5/K59 D-G5W/J59W D-G5BAL D-G59F/G5NTL D-A3C/A44C D-G39C/K39C MGQ BT-04 BT-04 BT-06 BT-08 BT-08 BA-04 BA-05 BA-06 BA-08 BA-10 MGG MGC BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 To order
D-A5/A6/A59W/F5/J5 D-F5W/J59W/F5NTL/F59F D-A3/A44/G39/K39 D-B5/B64/B59W/G5/K59 D-G5W/K59W/G59F/G5NTL CC BT-04 BT-04 BT-06 BT-08 BT-08 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M RB BA-04 BA-05 BA-06 BA-08 BA-10 D-A3C/A44C/G39C/K39C BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 J D-Z7/Z80/Y59/Y69/Y7P D-Y7PV/Y7W/Y7WV BA4-040 BA4-040 BA4-063 BA4-080 BA4-080 DMounting bracket belongs to D-A3C/A44C/G39C
Electrical entry/Function Bore size (mm) 40 Model No. of auto switch 50 63 80 100 D-B5/B6 Grommet Band mounting Tie rod mounting Band mounting Tie rod mounting D-B59W Grommet (2 color indication) D-A5/A6 D-A59W D-F5l/J5l D-F5lW/J59W D-F5NT D-F5BAL/F5lF D-A3l Terminal conduit Reed switch Solid state switch D-A44 DIN terminal BT-04 BT-04 BT-06 BT-08 BT-08 D-A5/A6 Grommet D-A59W Grommet (2 color
Made to Order How to Order 2 1 F 06 200 AS S Lubricant: Vaseline -X12 Example) AS2002FS-04-X12 Made to Order Body size Grease-free (Seal: Fluorine-coated) + Restrictor (Without check valve) -X21 100 M5 standard 200 1/8 standard 205 1/4 standard 300 3/8 standard 400 1/2 standard Applicable tubing O.D.1 Example) AS2002FS-04-X21 Not particle-free Metric size Inch size 23 3.22 04 4 06 6 08 8
Suction Filter with Case FH99 Series How to Order 04 0 0 0 M 074 FH99 0 Companion flange Suction filter with cace Nil None With companion flange F Construction/Connection 0 1 Common with L-type threaded and flange L-type flange Nominal filtration 074 105 149 74 m 105 m 149 m Port size (Outlet side) 1/2B 04 06 08 10 12 16 20 24 28 32 3/4B M Micromesh Element Differential pressure indication
How to Order With bracket (standard) Air suction filter In-line type with One-touch fitting 100 04 B ZFC IN/OUT applicable tube O.D.
Bore size (mm) Auto switch model 40 50 63 80 100 D-A5/A6/A59W/F5/J5 D-F5W/J59W/F5NTL/F59F D-A3/A44/G39/K39 D-B5/B64/B59W/G5/K59 D-G5W/K59W/G59F/G5NTL BT-04 BT-04 BT-06 BT-08 BT-08 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M BA-04 BA-05 BA-06 BA-08 BA-10 D-A3C/A44C/G39C/K39C BA3-040 BA3-050 BA3-063 BA3-080 BA3-100 D-Z7/Z80/Y59/Y69/Y7P D-Y7PV/Y7W/Y7WV BA4-040 BA4-040 BA4-063 BA4-080 BA4-080 Mounting
Port size AS-D U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 AS-T ASP Needle Valve/Flow Rate Characteristics ASN AS2201FSl-U02, AS2211FSl-U02 AS2201FSl-U01, AS2211FSl-U01 300 600 AQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 500 ASV 06, 07, 08, 09, 10 08, 09, 10, 11 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] 03, 04 06, 07 200 400 AK 01, 23 300 VCHC 03, 04 100 200 ASR ASQ 01, 23
Auto switch models Bore size (mm) 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F5BA/F59F/F5NT D-A5/A6/A59W D-Z7/Z80 BS5-125 BMB5-032 BA7-040 BA7-040 BA7-063 CHQ CHK BT-12 BT-03 BT-04 BT-04 BT-06 CHN BS4-125 BMB4-032 BA4-040 BA4-040 BA4-063 Note 1) D-A5/A6/A59W cannot be mounted to 40, 50.
Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 Auto switch model Foot 50 63 80 100 CA1-L04 CA1-L05 CA1-L06 CA1-L08 CA1-L10 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NT D-F5BAL/F59F Flange CA1-F04 CA1-F05 CA1-F06 CA1-F08 CA1-F10 Single clevis CA1-C04 CA1-C05 CA1-C06 CA1-C08 CA1-C10 BT-04 BT-04 BT-06 BT-08 BT-08 Double clevis CA1-D04 CA1-D05 CA1-D06 CA1-D08 CA1-D10 When ordering foot bracket
-X538 34.4 75.2 118.7 262.7 AW40-04G-A Y400T-A E400-04-A VP744-5DZ1-04-X555 34.4 75.2 160.2 304.2 AW40-04G-A Y400T-A E400-04-A 17 VP500/700-X536, X538, X555 Specific Product Precautions Be sure to read this before handling.
Symbol ZFA ZFB ZFB ZFC How to Order Metric size Applicable tubing size Metric size (Release button: Light gray) Symbol Bore size Applicable model ZFB 0 04 10 Metric size ZFB10 ZFB20 ZFB30 04 06 08 10 4 6 8 10 ZFB 1 10 05 Inch size Inch size Body type Symbol Bore size Applicable model ZFB10 ZFB20 ZFB30 ZFB40 Symbol Filtration area (mm2) 05 07 11 13 " " 3 16 1 4 10 20 30 40 1037 1584 1980
Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 Auto switch model Foot 50 63 80 100 CA1-L04 CA1-L05 CA1-L06 CA1-L08 CA1-L10 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NT D-F5BAL/F59F Flange CA1-F04 CA1-F05 CA1-F06 CA1-F08 CA1-F10 Single clevis CA1-C04 CA1-C05 CA1-C06 CA1-C08 CA1-C10 BT-04 BT-04 BT-06 BT-08 BT-08 Double clevis CA1-D04 CA1-D05 CA1-D06 CA1-D08 CA1-D10 When ordering foot bracket
Without auto switch 4, 6, 8, 10 Bore size (mm) M3 x 0.5 6 Port size Stroke (mm) 8 or more AS121F-M3-23 AS121F-M3-04 AS131F-M3-23 AS131F-M3-04 Note) Only applicable to the mounting position shown in Figure 1 below. Figure 1 Mounting position 1 Mounting position 2 a) Side mount b) Front mount Mounting position 3 Mounting position 4 Notes) 1.
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
1 3 Port Air Operated Valve Series VGA342 How to Order SA 04 VGA342 A VA Port size Passage A Normally closed (N.C.) B Normally open (N.O.) Thread type Nil Rc F G N NPT T NPTF 04 1/2 06 3/4 10 1 SA VA JIS Symbol VM N.C. N.O.
(mm)Connection threadsModel Elbow typeUniversal type Meter-outMeter-inMeter-outMeter-in12R 1/2AS4201FG-04-12AS4211FG-04-12AS4301FG-04-12AS4311FG-04-12
How to Order VR 12 1 1 F 06 Body size Applicable tubing outside diameter Metric sizes Inch sizes 1 1/8 standard 3.2 23 04 06 01 03 07 1/8" 5/32" 1/4" 4 6 Use 1/8" tubing for 3.2.
How to Order ZFB 100 04 IN/OUT applicable tubing O.D.
(mm) 50 50 M10 x 1 M14 x 1 Thread dia./ Port size Connection A10 A14 Symbol B5 M5 x 0.8 Female thread Pad type Vacuum entry B01 Rc 1/8 F Ball joint type 04 4 tube One-touch fitting 06 6 tube 08 8 tube Material N NBR S Silicon rubber Buffer stroke U Urethane rubber Symbol Stroke Pad dia.