SMC Corporation of America
Elite Part Number Search
Search Results "ISE20C-V-N02L-W"

Terminal name Details 1 L+ +24 V 2 NC N/A 3 L 0 V 4 C/Q IO-Link signal * For , enter a number from the No. line in the table on page 6. Refer to the dimension drawings on page 6 for the mounting dimensions.

Linked/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø1/4, 1st Selection Quantity: 8, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal

o Valve, w/o Energy Saving Function, 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 4, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity

/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 5, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle

/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 9, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle

/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 8, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle

/N.C., 1st Selection Vacuum V Port: Vacuum, V Port: Ø6, 1st Selection Quantity: 8, /: -, 2nd Nominal Nozzle Size: -, 2nd Selection Supply Valve and Release Valve: -, 2nd Selection Vacuum V Port: -, 2nd Selection Quantity: -, /: -, 3rd Nominal Nozzle Size: -, 3rd Selection Supply Valve and Release Valve: -, 3rd Selection Vacuum V Port: -, 3rd Selection Quantity: -, /: -, 4th Nominal Nozzle

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H Hysteresis The difference between ON and OFF points used to prevent chattering. Hysteresis can be effective in avoiding the effects of pulsation.

2-wire 3-wire(NPN) IC circuit Diagnosis (2-color indicator) MHW MHW 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire -X M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA 3-wire(PNP) MRHQ M9BAV M9BA 12 V 2-wire Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Description Function 1 SV24 V +24 V for solenoid valve. 2 SV0 V 0 V for solenoid valve 3 SW24 V +24 V for SI unit and Input Block 4 SW0 V 0 V for SI unit and Input Block 5 FE Ground -13No.EX-OME0014-F Maintenance Addition of Input Block Remove screws from End Plate. Mount attached tie rod. Connect additional Input Block.

IDX-OM-W017-E / Series IDFA3E-23-A,C IDFA4E-23-A,C,L,R,T,V IDFA6E-23-A,C,K,L,R,T,V IDFA8E-23-A,C,K,L,R,T,V IDFA11E-23-A,C,K,L,R,T,V IDFA15E1-23-A,C,K,L,R,T,V URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO 4414: Pneumatic fluid power General rules and safety requirements for systems and

Technical documentation giving detailed accessories information can be found on the SMC website (URL http://www.smcworld.com). 5 SV0 V 0 V for valve 2 1 4 3 SW24 V +24 V for SI unit and input URL http://www.smcworld.com SW0 V 0 V for SI unit and input 4 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 5 FE Ground Example of

Relief valve Petroleum Water-glycol, Emulsion Phosphoric ester 0 1 2 N W V The micromesh element is a made to order specification (X0). Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number.

Element Relief valve P M Paper Micromesh 0 1 With relief valve None Hydraulic fluid 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.

Hydraulic fluid Petroleum Water-glycol, Emulsion Phosphoric ester 0 1 2 N W V Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.

(g) Note 3) W = 65.4n + m + 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated simultaneously, supply pressure to port P on both sides and exhaust from port R on both sides, using "stations B (SUP/EXH block both sides)".

3 w e q !1 r y o e t !2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 4 Built-in magnet Without magnet Single acting u i r y o e w i e u !

Auto switch operating range (mm) Bore size (mm) Auto switch model 20 25 32 40 50 63 80 100 D-A9(V) 9 9 9 9.5 9.5 11 10.5 10.5 D-M9(V) D-M9W(V) 5.5 5 6 5.5 6 6.5 6 7 D-M9A(V) D-Z7/Z80 10 10 10.5 10.5 10.5 11.5 11.5 12 D-Y5/Y6 D-Y7P(V) 7.5 7 6.5 6 7 8 9.5 10 D-Y7W(V) D-Y7BA D-P3DWA 5.5 6 6.5 6 6.5 6 6 D-P3DW 6 5.5 5.5 5.5 6.5 7.5 7.5 D-P4DW 5 4 4 5 4 4 * Since this is a guideline including

Option Symbol and Composition Fluid Name and Option Option symbol and body material Brass Stainless steel Option symbol Seal material Body material Support material (Driving parts) Standard A B G H J M (Non-leak) N P V (Non-leak) Fluid (Application) V M Silicon oil A H NBR FKM EPDM NBR FKM EPDM FKM FKM EPDM FKM Note 1) Note 1) Vacuum (up to 1.3 x 101 Pa) Fuel oil (up to 60C) Brass A H V M