SMC Corporation of America
Elite Part Number Search
Search Results "HRS200-AN-46"

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)], Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: D [Panel Mount Adapter + Front Protection Cover, (ZS-46-D)], Operation Manual: -

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: B [Panel Mount Adapter, (ZS-46-B)], Operation Manual: -

Resistant / Heat Resistant, Vacuum Outlet Port: -, Pad diameter(ø): 46, Vacuum entry port thread diameter: -, Mounting connection screw: -, Type: Pad unit

Model: 42 (Dual AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: 8H (ø8 Straight), Plug Position: Q (High-voltage Cable Side), Input, Output Specification: P (PNP), Power Supply Cable Length: N (None)

Model: 41 (AC), Bar Length: 46 (460mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 1 (1m), One-touch Fitting: 6H (ø6 Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: P (PNP), Power Supply Cable Length: 10 (10m)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A (ZS-46-A1)]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]