This is a legacy product. Please contact us for the latest version.sales@ocaire.com MGP COMPACT GUIDE CYLINDER. CYLINDER. ACTUATOR. 25MM MGP SLIDE BEARING. 9.86109 lb. IM.
Series CG1 precision air cylinder has 8 bore sizes and can meet any application need. The tube is impact extruded aluminum to produce an extraordinarily smooth finish, allow low break-away pressure and smooth stroke action. Eight mounting options are available. Auto switch capable. Standard: single acting, single rod, spring return/extend, Bore sizes *: 20, 25, 32, 40, Strokes *: 25~200,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com MGP COMPACT GUIDE CYLINDER. CYLINDER. ACTUATOR. 100MM MGP SLIDE BEARING. SM.
Magnet: Built-in Magnet, Mounting: Basic, Type: Rubber Bumper, Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 300mm, Thread: Male Rod End, Suffix for Cylinder: w/o Rod Boot, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9BWV--Solid State, 2-color Indication, 2 Wire, Vertical, Lead Wire or Prewire Connection: 0.5m Cord Length
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in Magnet), Mounting: B (Basic), Type: N (Rubber Bumper), Bore: 40mm, Port Thread Type: Rc (or M5, Depending on Style, Bore Size, and Thread Combination), Stroke: 100mm, Rod End Thread: Rod End Male Thread, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connectors: L (3m)
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BW, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 320, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: G5BA, Lead Wire