Stations: 3 Stations, Port Size: 02 (Rc1/4), Thread Type: T (NPTF), Kit Name: PD2 (Flat Ribbon Cable w/3.0m)

Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 0 (Individual), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: DO (DIN Connector w/o Connector), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: Non-locking Push Type, A, B Port Size: 02 (1/4), Thread: T (NPTF)

Body Size: 25, Thread: N (NPT), Port Size: 02 (1/4), Option: Standard, Attachment: TV (T + V), Semi-Standard 1: 8 ( Metal Bowl w/Level Gauge), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial Units: psi, °F)

Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: DO (DIN Connector w/o Connector), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 02 (Body Ported 1/4), Thread: T (NPTF)

Series: 3 (VQZ3000), Configuration: 3 (3 Position Closed Center), Seal Type: 0 (Metal Seal), Function: KR (High Pressure 0.9W - DC Only, External Pilot), Coil Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire, Light & Surge Suppressor), Manual Override: Non-locking Push Style, IP65 Compliant: No, Port Size: 02 (Rc1/4), Thread: T (NPTF)

Function: 1 (2 Position Single), Body Option: 20 (Body Ported/Individual Pilot EXH), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: T (Conduit Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: A (Non-locking Push Extended Style), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4)

Body Size: 30, Thread: N (NPT), Port: 02 (1/4), Option: Standard, Attachment: TV (T + V), Semi-Standard 1: Standard, Semi-Standard 2: WZ (W + Z)

Compressor Output 5HP, (3.7kW)], Thread: Rc, Port Size: 02 (1/4), Accessory: None, Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: Standard, Air Pressure: Standard, Drain Guide: J (Drain Guide 1/4 Female Threaded), IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)

Compressor Output 5HP, (3.7kW)], Thread: Rc, Port Size: 02 (1/4), Accessory: B (Bracket), Auto Drain: Drain Cock w/o Auto Drain, Rubber Material: Standard, Air Pressure: Standard, Drain Guide: J (Drain Guide 1/4 Female Threaded), IN-OUT Direction: Standard, Pressure Switch 125VAC, 30VDC: None, Element Service Indicator: T (Yes)

Function: 1 (2 Position Single), Body Option: 1 (Non Plug-in Common Electrical Entry), Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Manual Override: B (Locking Slotted Style), Port Size: 02 (Base Mounted w/Sub-plate 1/4, Side Piping), Thread: T (NPTF)

Model: 33, Orifice: 4 (4mm), Style: 4 (COM, Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: S (w/Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)

Model: 33, Orifice: 2 (2.2mm), Style: 0 (N.C., Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 02 (1/4), Thread: T (NPTF), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)

Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: B (24VAC), Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed)

Series: 342 (VP300), Pilot Type: Internal Pilot, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 4 [220VAC (230VAC), 50/60Hz], Electrical Entry: T (Conduit Terminal), Light & Surge Suppressor: w/o Light & Surge Suppressor, Manual Override: Non-locking Push Type, Port Size: 02 (1/4), Thread Type: N (NPT), Actuation Type: A (N.C., Normally Closed)

Function: 2 (2 Position Double), Body Option: 10 (Base Mounted Non Plug-in), Pilot: R (External Pilot), Voltage: 3 (110~120VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: Side, Port Size: 02 (Base Mounted w/Sub-plate 1/4, Body Ported 1/4), Thread: T (NPTF)

Rod O.D.Applicable tubing O.D. 10 20 25 30 M5 standard 01 standard 02 standard 03 standard 04-04 06-06 08-08 10-10 4 4 6 6 8 8 10 10 wBring up the body, while holding it down. w eTake the finger off the release ring and remove the speed controller from the One-touch fitting.

Made to Order Specifications (For details, refer to page 14-20-55.) 01 B 06 B 1 8 3 4 1B 02 03 10 14 B 1 4 B 3 8 04 B 1 2 Note) Refer to How to Order Bowl Assembly on page 14-20-59. 1 B 1 2 20 2B Caution Accessory/Option Combinations Available Not available Depends on model Be sure to read before handling.

Actuation Type: 2 (2 Position Double), Sealant: 0 (Metal Seal), Function: R (External Pilot), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: B (Locking Slotted Style), Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 02 (1/4), Thread: T (NPTF)