The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal

The SYJ Valve is an innovative combination of space efficiency and performance superiority which provides real value to the design solution. Whether designed in a manifold or used as a single valve, this small profile increases design flexibility and minimizes space requirements. The SYJ valve utilizes a low power (0.5 watts standard) pilot solenoid design, which dramatically reduces thermal

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Part Number Description: MANIFOLD NVK3000 8 STA   Product Line: V   Product Line Description: VALVE   Family Code: 345   Family Description: VV5K* MANIFOLD VK 4/5 PORT   Class Code: NJ   Part Code: 2   Reference Code:  K   Click here to report information errorImage shown may not match exact part number

. / N.C.), Pressure Sensor/Digital Pressure Switch for Vacuum Spec: J (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only), Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum (V) Port: 08 [ø8 One-touch Fitting

Self-holding Release Valve Linked / N.C.), Pressure Sensor/Digital Pressure Switch for Vacuum Spec: J (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only), Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum (V) Port: 08

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Switch / Pressure sensor: D (Switch, 0 to -101 kPa, SI Units Only, PNP 2 Outputs), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 (ø8 One-touch Fitting, Metric)

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: R (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / PNP 1 Output), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 08 [ø8 One-touch Fitting (Metric)]

Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: R (Self-holding Release Valve Linked / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 08