Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, AB, AS***F M5 STANDARD (PT), .02484 lb
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CTL, CLEAN-ROOM, AIRLINE EQUIPMENT, AS FLOW CONTROL, A5, AS M5 CLEAN-ROOM, .06305 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight (g) Flow
M5 tightening torque: 3 to 4.5Nm Do not touch equipment other than the terminal block during wiring. 2 5 2. Transportation and installation 3. Put back the front panel. [Wiring for operation, error signal and remote control] Specifications of signal cable Prepare the following cable.
M5 tightening torque: 3 to 4.5Nm Do not touch equipment other than the terminal block during wiring. 3. Put back the front panel. [Wiring for operation, failure signal and remote control] Specifications of signal cable Prepare the following cable.
When the product is mounted using the bracket, fix with M5 screws (2 pcs.) or equivalent. The Bracket thickness is approx. 1.6 mm.
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT)Speed controller standard in-line style, Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2, Port sizes: M3, M5, 01, 02, 03, 04, SPEED CTRL, W/FITTING,, AIRLINE EQUIPMENT, AS FLOW CONTROL, AB, AS M5 STANDARD (PT), .08818 lb, ModelPort sizeFree flowControlled flowApplicable cylinder bore size (mm)Weight
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, AB, AS***F M5 STANDARD (PT), .56830 lb
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 3-phase 4 cores x 380 to 415V AC AWG10 HRS400-A(50Hz/60Hz) (4 cores x 5.5 mm2) M5 R5.5-5 40 30 463-phase including 460 to 480V ground AC(60Hz
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 (4 cores x 5.5 mm2) HRL100-A-20 3-phase R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 HRL100-A-20 3-phase (4 cores x 5.5 mm2) R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
Table 3-3 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker *1 Terminal Cable Model Power supply block Recommended Sensitivity specifications Rated voltage screw crimp terminal of leakage *2 current diameter current (A) (mA) 380-415 VAC 4 x 5.5 mm2 50/60Hz 3 phase, (4 x AWG10) HRS200-A-46-S M5 R5.5-5 30 30 *Including 460-480 VAC 60Hz ground 3 phase *1.
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
2 VX3 ) VXA How to Order VN VXH2230 02 1 G LVC LVA Bracket Nil B 3 -B JIS Symbol LVH LVD Valve/Body 0 3 ' +0 Electrical option Nil 3 LVQ S ( L LQ Z + ( Port size 6 ( 2 (-' LVN 02 03 04 6 +" 6 &+$ 6 +! TI/ TIL Electrical entry G 8 PA Rated voltage C ) 2 ! >) +# = 1 >) +# = D 543 PAX T ) 3 >) +# = 6 ( 4 !! >) +# = PB 7 !"
Fluoro rubber is used for the rubber parts of seals How to Order Manifolds -lI O Ozone resistant specifications ilTv2o port size EI 114 {xt 3/8 type How to Order Manifold Assemblies shtionu "o,.,) llTV20-02-3. lset (3 station manifold base part no.) lTV2030-312S-X26 . . .. .. . . l set (Electro-pneumatic regulator part no.)
BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
Port size SRP SRH3000 URJF 1/4 SRH4000 URJF 3/8 Piping port size Rc 1/8 Rc 1/4 Rc 3/8 Rc 1/2 With metal gasket seal fitting With metal gasket seal fitting Symbol 01 02 03 04 A2 A3 X210 EPDM seals SRF With relief port fittings (Applicable tube O.D.: 4) X211 X216 ITV Machined relief port M5 thread Knob operation product with reduced torque X233 IC X234 Aluminum body ITVH Note) The pressure