[mm] (Reference value) 17 Weight 5.5 Most sensitive position [g] Auto switch model D-M9Nm-5 D-M9Pm-5 D-M9Bm-5 0.5 m (Nil) 7 6 Lead wire length 1 m (M) 13 11 3 m (L) 35 31 5 m (Z) 57 51 17-E683 D-M9m-5
V oltage: 30 VDC Current: 5 to 50 mA DC Note: The connection example in 2.3 shows sink circuits. 15 - (2) Line Driver Output Circuit CN1 connector terminals, 17-18 (phase-A signal), 19-20 (phase-B signal), and 21-22 (phase-Z signal) are explained below. These terminals output the following signals via the line-driver output circuits.
Wait for about 10 to 15 minutes as a guide. When carrying out maintenance work on the auto drain strainer and auto drain, there is a risk of touching the drain fluid during work. Please follow the safety procedure for operators specified by customer.Example: carry out work wearing safety glasses, apron and gloves to prevent discharged fluid from touching the human body.
.* * This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed so that only purge air flows through the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. Selection Caution a. Do not obstruct the purge air discharge ports.
.* * This time can be shortened as described below. 1) Provide a valve on the outlet side of the membrane air dryer. 2) Supply air with the valve closed so that only purge air flows through the membrane air dryer. 3) After 15 minutes or more, open the valve and let air flow to the outlet side equipment. Selection Caution a. Do not obstruct the purge air discharge ports.
6 t Zinc chromated w Electroless nickel plated Black zinc chromated Accessory Accessory IN 2 Series ARJ310 Dimensions ARJ310-01 ARJ310F-01 Approx. 31 Approx. 56 Approx. 56 Approx. 35 32 22 M12 x 1 Panel fitting dimensions 12.5/Panel thickness: 4 or less Approx. 27 19 2 2 -5.5 Approx. 57.2 8.5 Approx. 82.5 15 Applicable tube O.D. 4, 6, 5/32, 1/4 Port size Rc, NPT 1/8 2 2 1 1 Pressure gauge
6 22 IDW08N 33 8 11 3.6 25 IDW10N 3/8" 36 10 32 IDW15N 43 15 42 IDW25N 53 25 57.5 Simplex IDW35N 68 35 28.0 IDW45N 117 45 31.8 3/4" IDW55N 130 55 36.0 IDW65N 141 65 7 43.5 IDW85N 85 165 1" 55.8 IDW105N 105 200 20.5 63.5 IDW135N 135 224 1-1/4" 79.5 IDW175N 175 271 55.8 IDW215N 215 378 13.5 63.5 Duplex 1-1/2" IDW275N 275 422 79.5 IDW365N 365 510 1.
21 5 SIG OUT IN1 OUT1 SIG 2 IN2 OUT2 OUT 5 x Rc1/4 60 IL220 14.5 Panel fitting dimension 2 x 6.6 45 58 Panel 35 Max. 4 2 18 57 10 130 2 OUT IN1 SIG 30 15 4 x Rc1/4 IN2 60 58
21 5 IL1 SIG OUT IN1 OUT1 SIG 2 IL2 IL2 IN2 OUT2 IT OUT 5 x Rc1/4 CP 60 IS IL220 VFN 14.5 INT Panel fitting dimension 2 x 6.6 45 58 Panel 35 Max. 4 2 18 57 10 130 2 OUT IN1 SIG 30 15 4 x Rc1/4 IN2 60 173
RA Robotic cable 10 m*1 RB Robotic cable 15 m*1 When selecting an electric actuator, refer to the model selection chart of each actuator. Also, for the SpeedWork Load graph of the actuator, refer to the LECPMJ section on the model selection page of the electric actuators Web Catalog.
Weight (g) L1 M Width across flats H1 H2 Nozzle size D Model KN-04-100 KN-04-150 KN-06-100 KN-06-150 KN-06-200 KN-08-150 KN-08-200 KN-10-250 KN-10-300 KN-10-350 KN-10-400 KN-10-600 KN-12-350 KN-12-400 KN-12-600 KN-16-400 KN-16-600 KN-20-400 KN-20-600 13 14 19 20 22 28 30 35 36 37 30 28 54 55 40 77 79 117 112 15 15 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 27 27.7 30.1 30.8 31.5 33.8
1 Stainless steel M4 x 0.7 x 8 Cross-recessed head cap screw Cross-recessed head cap screw Steel wire M4 x 0.7 x 8 M3 x 0.5 x 6 !0 !2 NBR 14284 O-ring 143021 !1 15-9-41 3 Dimensions AS2000E/3000E 2-port size L7 Max. Min.
closing width (mm) Finger opening width (mm) Stroke (mm) 11221122MHR2-10 MDHR2-10 MHR2-15 MDHR2-15 6 105 (100) 12 12 10 16 10 Vacuum suction type M3 x 0.5 11221122185 (180) 24 25 14 22 8 15 Double acting Non-lube 11221122400 (390) 780 (760) MHR2-20 MDHR2-20 MHR2-30 MDHR2-30 33 34 16 28 12 20 M5 x 0.8 1122112230 58 59 19 37 18 Note 1) Refer to the Best Pneumatics No. 4 for details of gripping
MXJ8 5, 10, 15, 20 Stroke adjuster is mountable on the axial piping.
Model External Internal Open/Close stroke (Diameter) Port size Lubrication Gripping force N (Effective value at 0.5 MPa) Note 1) Nominal size Weight g Note 2) Action Model Finger opening width (mm) Finger closing width (mm) Stroke (mm) 11221122125 (130) MHR3-10 MDHR3-10 MHR3-15 MDHR3-15 Vacuum suction type 10 7 6.5 16 22 6 M3 x 0.5 Double acting Non-lube 11221122230 (235) 15 13 12 19 27 8
Moment (Nm) M3 M1 M2 2 Series CYP Dimensions T Y Depth ED T L E F PA K 4-MM 4-Counter bore dia.
+10% 15% Single phase 200 to 230VAC (50/60HZ ) For 100V Single phase 100 to 115VAC (50/60HZ ) R T 1MCCB Equipment Connection Example Noise filter External noise is prevented by the noise filter.
Maintenance. 15 4.1 Maintenance of Ionizer . 15 4.2 Valve Maintenance . 16 -1- These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions are categorized into three groups, "Caution", "Warning" and "Danger" depending on the level of hazard and damage, and the degree of emergency.
Maintenance. 15 4.1 Maintenance of Ionizer . 15 4.2 Valve Maintenance . 16 -1- These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions are categorized into three groups, "Caution", "Warning" and "Danger" depending on the level of hazard and damage, and the degree of emergency.
PAB*-OMY0027 PRODUCT NAME Process Pump MODEL / Series / Product Number PA5013 Contents Safety Instructions -P.2 to 3 Names and functions of parts P.4 Precautions -P.5 to 9 Applicable Fluids P.10 Specifications P.11 Performance Curve P.12 to 14 Working Principle P.15 Maintenance Parts P.15 Piping and Operation P.16 Dimensions P.17 1 Safety Instructions These safety instructions are intended