SMC Corporation of America
Elite Part Number Search
Search Results "RZQL50TN-50-10-M9NL"

CCVS10-U1 Solenoid valve rated voltage 0 2 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 24 VDC 12 VDC 240 VAC, 50/60 Hz L 1 0, 1, 2, 3 2 0, 1, 2, 3 Semi-standard Specifications Combined valve Control valve Stop valve, Skip valve Specifications Throttle valve Flow control valve Small flow Large flow Small flow Large flow Timid flow Small

14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 18 4 4 10.4 20.7 D1 10 L2 A D2 8 H 6 19.5 10 10 12.8 22.8 Connection threads 10 (R) 8 (R) 15.2 21.5 26 18 12 26.3 Applicable tubing 10 18.5 24 41 29 29.4 M L1 17 17 12 20.9 25 58 46 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 18 4 4 10.4 20.7 D1 10 L2 A D2 8 H 6 19.5 10 10 12.8 22.8 Connection threads 10 (R) 8 (R) 15.2 21.5 26 18 12 26.3 Applicable tubing 10 18.5 24 41 29 29.4 M L1 17 17 12 20.9 25 58 46 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5 12.8 22.8 Connection threads 10 (R) 8 (R) 15.2 18 26 21.5 12 26.3 Applicable tubing 10 18.5 29 41 24 29.4 M L1 17 17 12 20.9 46 58 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

The cable connecting the actuator and controller (LEC) is superior in bending resistance, but should not be placed into a flexible moving tube with a radius smaller than the specified value. ( Min. 50 mm) 10. Confirm proper wiring of the product.

Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110

10%1 Current consumption 55 mA or less Protection Polarity protection Power supply voltage for sensor1 [Power supply voltage] 1.5 V Power supply current for sensor2 Max. 50 mA (However, the total current for the 4 inputs is 200 mA maximum or less.)

Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5

Specifications 1-1 Specifications Fluid Air Proof pressure 1.5MPa Max. operating pressure 1.0MPa Min. operating pressure 0.05MPa Ambient and fluid temperature -10 to +70oC. -10 to +60oC with built-in magnet (No freezing) Lubrication Not required (non-lube) to 250st +1.0 mm 251 to 1000st +1.4 mm 1001st to 1500st +1.8 mm 0 Stroke length tolerance 0 0 Cushion Air cushion Pistonspeed 50 to 500mm

Made to Order (Please contact SMC for specifications in detail, dimensions and delivery.) 10 m roll 50 m reel 100 m reel Model TFU0425 TFU0604 TFU0805 TFU1065 TFU1208 1. Change of color (10 m roll) 4 Tubing O.D. (mm) 6 8 10 12 Suffix -X4 to the end of part number. Ex.) TFU0604BU-2-10X4 2.5 Tubing I.D.

14 8 10 14 12 14 4 10 19 6 12 20 13 21 26 36 38 65 4 4 4 18 10.4 20.7 D1 10 L2 A D2 8 H 6 10 10 19.5 12.8 22.8 Connection threads 10 (R) 8 (R) 15.2 18 26 21.5 12 26.3 Applicable tubing 10 18.5 29 41 24 29.4 M L1 17 17 12 20.9 46 58 25 31.4 22 D1 Reference dimension for R threads after installation Note 1) D1 indicates the maximum diameter.

Note) D: Max. diameter 8.4 27.5 34.1 30.6 12.7 2.2 2.2 8.4 10 3.2 10 30.1 2.2 2.2 3.2 2.7 R 1 8 M5 x 0.8 28.2 31.3 12.7 34.8 9.3 4 9.3 10 10 30.3 30.8 4.5 4.5 2.2 2.2 11 11 R 1 8 33.4 36.9 M5 x 0.8 K 11.6 13.5 11.6 10 10 6 32.9 R 1 8 M H D MS 2-applicable tubing T VMG T (With seal) Plug-in Reducer: KJR Effective area (mm2) Nylon Urethane Applicable tubing O.D.

A 2 A Power supply (Output) 24 VDC +10/-5%, 24 VDC +10/-5%, 8 A DC24 V +10/-5%, 4 A 2 A Enclosure IP67 (With manifold assembled) 1 Environment Operating temperature range -10 to 50 oC Storage temperature range -20 to 60 oC Operating humidity range 35 to 85%R.H.

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN, VALVE

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC

Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC